This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.210
66.879%
0.031
5.101V
0.314
115.23V
2
0.087A
0.442
75.042%
0.058
5.101V
0.589
115.23V
3
0.542A
2.757
80.076%
0.258
5.090V
3.443
115.22V
4
1.002A
5.087
77.819%
0.357
5.079V
6.537
115.22V
5
1.501A
7.608
77.625%
0.407
5.068V
9.801
115.22V
6
2.501A
12.613
75.288%
0.458
5.044V
16.753
115.22V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.210
58.824%
0.011
5.101V
0.357
230.51V
2
0.087A
0.442
69.279%
0.019
5.101V
0.638
230.51V
3
0.541A
2.756
77.372%
0.101
5.090V
3.562
230.51V
4
1.002A
5.087
77.890%
0.170
5.079V
6.531
230.51V
5
1.501A
7.606
77.954%
0.228
5.067V
9.757
230.51V
6
2.501A
12.615
77.631%
0.305
5.044V
16.250
230.51V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.582A
1.997A
1.987A
0.980A
64.750
86.146%
455
10.9
38.53°C
0.958
12.055V
5.009V
3.317V
5.077V
75.163
42.03°C
115.23V
2
8.209A
2.993A
2.986A
1.180A
129.721
89.701%
455
10.9
38.84°C
0.978
12.045V
5.002V
3.312V
5.070V
144.615
43.20°C
115.23V
3
13.186A
3.511A
3.503A
1.380A
194.835
90.682%
435
9.9
39.16°C
0.984
12.037V
4.996V
3.307V
5.065V
214.856
44.09°C
115.22V
4
18.167A
4.010A
3.992A
1.580A
259.692
90.865%
455
10.9
39.69°C
0.986
12.028V
4.989V
3.302V
5.058V
285.800
45.30°C
115.22V
5
22.815A
5.012A
5.002A
1.780A
324.643
90.590%
435
9.9
40.27°C
0.987
12.018V
4.983V
3.296V
5.051V
358.364
45.92°C
115.22V
6
27.459A
6.034A
6.012A
1.980A
389.602
90.116%
435
9.9
40.86°C
0.986
12.011V
4.975V
3.291V
5.044V
432.334
47.51°C
115.22V
7
32.111A
7.043A
7.027A
2.180A
454.496
88.747%
895
25.4
41.96°C
0.985
12.003V
4.969V
3.286V
5.037V
512.124
49.24°C
115.21V
8
36.789A
8.069A
8.048A
2.384A
519.526
87.828%
1415
38.2
42.92°C
0.986
11.990V
4.962V
3.280V
5.029V
591.528
50.98°C
115.22V
9
41.881A
8.578A
8.579A
2.385A
584.544
86.827%
1795
44.4
43.59°C
0.987
11.985V
4.956V
3.275V
5.028V
673.228
53.09°C
115.22V
10
46.957A
9.092A
9.082A
2.485A
649.363
86.168%
1795
44.4
44.61°C
0.988
11.972V
4.951V
3.270V
5.023V
753.603
54.78°C
115.21V
11
52.391A
9.097A
9.087A
2.487A
714.295
85.406%
1795
44.4
46.12°C
0.989
11.970V
4.947V
3.267V
5.020V
836.353
57.61°C
115.22V
CL1
0.095A
12.014A
12.005A
0.004A
100.466
84.532%
555
13.1
44.96°C
0.975
12.042V
4.973V
3.295V
5.096V
118.849
57.68°C
115.23V
CL2
54.094A
1.005A
1.003A
1.001A
662.011
86.828%
1800
44.4
45.29°C
0.988
11.991V
4.978V
3.290V
5.062V
762.439
55.83°C
115.21V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.589A
1.994A
1.983A
0.984A
64.826
85.427%
455
10.9
40.15°C
0.774
12.050V
5.015V
3.321V
5.075V
75.885
43.39°C
265.12V
2
8.217A
2.991A
2.979A
1.181A
129.824
90.062%
435
9.9
40.77°C
0.891
12.043V
5.013V
3.319V
5.069V
144.149
44.35°C
230.26V
3
13.181A
3.498A
3.492A
1.380A
194.894
91.680%
435
9.9
41.20°C
0.928
12.047V
5.012V
3.317V
5.063V
212.580
45.59°C
230.26V
4
18.157A
3.995A
3.979A
1.581A
259.786
92.244%
455
10.9
41.61°C
0.946
12.039V
5.009V
3.315V
5.056V
281.629
46.70°C
230.26V
5
22.793A
4.990A
4.975A
1.781A
324.704
92.262%
455
10.9
42.13°C
0.955
12.032V
5.007V
3.313V
5.049V
351.935
47.43°C
230.29V
6
27.437A
5.994A
5.976A
1.980A
389.700
92.086%
435
9.9
42.57°C
0.961
12.025V
5.005V
3.311V
5.042V
423.193
48.39°C
230.32V
7
32.082A
7.001A
6.978A
2.181A
454.627
91.520%
1005
28.4
43.14°C
0.965
12.017V
5.004V
3.308V
5.035V
496.750
49.40°C
230.36V
8
36.742A
8.003A
7.983A
2.385A
519.607
90.934%
1425
38.6
43.78°C
0.968
12.008V
5.000V
3.307V
5.029V
571.409
50.52°C
230.34V
9
41.835A
8.505A
8.505A
2.385A
584.657
90.408%
1800
44.4
44.74°C
0.970
12.001V
4.998V
3.304V
5.026V
646.690
51.83°C
230.30V
10
46.876A
9.014A
8.994A
2.486A
649.492
90.043%
1800
44.4
45.18°C
0.972
11.995V
4.996V
3.302V
5.021V
721.311
52.61°C
000.00V
11
52.325A
9.017A
9.002A
2.488A
714.497
89.708%
1800
44.4
46.32°C
0.973
11.988V
4.994V
3.300V
5.019V
796.474
54.00°C
230.41V
CL1
0.100A
12.013A
12.006A
0.004A
101.245
84.694%
555
13.1
42.88°C
0.866
12.037V
5.010V
3.318V
5.096V
119.542
49.70°C
230.27V
CL2
54.122A
1.002A
1.001A
1.002A
663.183
90.797%
1800
44.4
45.06°C
0.972
12.006V
5.002V
3.309V
5.059V
730.399
52.41°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.208A
0.494A
0.479A
0.195A
19.633
73.200%
435
9.9
0.825
12.061V
5.017V
3.323V
5.096V
26.821
115.23V
2
2.445A
0.991A
0.990A
0.390A
39.721
82.620%
435
9.9
0.922
12.057V
5.013V
3.321V
5.092V
48.077
115.23V
3
3.681A
1.489A
1.504A
0.585A
59.803
86.123%
455
10.9
0.951
12.055V
5.010V
3.319V
5.087V
69.439
115.23V
4
4.909A
1.995A
1.987A
0.785A
79.736
87.778%
435
9.9
0.965
12.053V
5.008V
3.316V
5.081V
90.838
115.23V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.214A
0.490A
0.479A
0.196A
19.686
69.545%
455
10.9
0.477
12.056V
5.018V
3.324V
5.095V
28.307
230.25V
2
2.450A
0.990A
0.990A
0.391A
39.777
80.981%
455
10.9
0.652
12.053V
5.017V
3.323V
5.090V
49.119
230.25V
3
3.689A
1.486A
1.503A
0.586A
59.881
85.302%
435
9.9
0.754
12.050V
5.016V
3.323V
5.085V
70.199
230.25V
4
4.919A
1.996A
1.984A
0.785A
79.796
87.441%
435
9.9
0.814
12.038V
5.013V
3.320V
5.080V
91.257
230.53V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.7 mV
7.9 mV
12.7 mV
9.6 mV
Pass
20% Load
17.9 mV
8.1 mV
17.1 mV
6.8 mV
Pass
30% Load
16.3 mV
8.4 mV
13.5 mV
6.1 mV
Pass
40% Load
16.1 mV
9.0 mV
15.6 mV
7.4 mV
Pass
50% Load
16.7 mV
9.2 mV
17.5 mV
8.2 mV
Pass
60% Load
18.0 mV
11.1 mV
18.1 mV
13.9 mV
Pass
70% Load
17.7 mV
10.1 mV
21.9 mV
17.3 mV
Pass
80% Load
18.9 mV
12.0 mV
23.4 mV
18.8 mV
Pass
90% Load
19.5 mV
11.7 mV
27.2 mV
23.0 mV
Pass
100% Load
19.0 mV
13.4 mV
27.3 mV
19.7 mV
Pass
110% Load
19.7 mV
13.6 mV
31.8 mV
22.0 mV
Pass
Crossload 1
18.1 mV
11.6 mV
10.8 mV
6.5 mV
Pass
Crossload 2
17.9 mV
13.0 mV
27.9 mV
17.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
4.3 mV
6.1 mV
7.7 mV
6.2 mV
Pass
20% Load
6.3 mV
6.6 mV
7.3 mV
6.1 mV
Pass
30% Load
24.3 mV
7.1 mV
7.1 mV
7.0 mV
Pass
40% Load
18.6 mV
6.7 mV
8.2 mV
7.3 mV
Pass
50% Load
17.1 mV
7.0 mV
7.5 mV
9.6 mV
Pass
60% Load
16.9 mV
7.5 mV
8.5 mV
10.3 mV
Pass
70% Load
16.6 mV
7.4 mV
7.8 mV
17.8 mV
Pass
80% Load
16.6 mV
8.5 mV
8.0 mV
20.0 mV
Pass
90% Load
16.8 mV
8.6 mV
8.2 mV
22.2 mV
Pass
100% Load
16.9 mV
8.8 mV
9.2 mV
21.6 mV
Pass
110% Load
17.2 mV
9.2 mV
9.6 mV
19.2 mV
Pass
Crossload 1
5.1 mV
6.8 mV
9.1 mV
4.7 mV
Pass
Crossload 2
16.4 mV
8.3 mV
9.5 mV
14.6 mV
Pass
The results above are not used in the certification process
BitFenix Whisper 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted