This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.211
68.285%
0.050
5.124V
0.309
115.18V
2
0.087A
0.444
74.124%
0.095
5.123V
0.599
115.19V
3
0.541A
2.768
77.797%
0.332
5.112V
3.558
115.15V
4
1.001A
5.108
77.807%
0.402
5.101V
6.565
115.16V
5
1.501A
7.641
78.089%
0.437
5.090V
9.785
115.17V
6
3.001A
15.138
75.986%
0.484
5.045V
19.922
115.17V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.346A
1.986A
1.979A
0.980A
74.778
85.442%
0
| 6.0
45.07°C
0.970
12.240V
5.035V
3.331V
5.092V
87.519
38.68°C
115.20V
2
9.712A
2.978A
2.971A
1.180A
149.730
89.380%
0
| 6.0
45.77°C
0.981
12.239V
5.032V
3.328V
5.078V
167.521
38.91°C
115.20V
3
15.425A
3.479A
3.483A
1.380A
224.846
90.275%
510
10.3
39.09°C
0.986
12.238V
5.030V
3.326V
5.066V
249.067
46.08°C
115.19V
4
21.127A
3.976A
3.968A
1.580A
299.675
90.310%
560
10.5
39.45°C
0.988
12.236V
5.028V
3.324V
5.054V
331.830
46.78°C
115.19V
5
26.493A
4.976A
4.963A
1.784A
374.658
89.975%
560
10.5
39.97°C
0.988
12.236V
5.025V
3.323V
5.041V
416.404
47.44°C
115.19V
6
31.854A
5.977A
5.959A
1.985A
449.557
89.438%
560
10.5
40.98°C
0.989
12.236V
5.023V
3.320V
5.030V
502.645
48.56°C
115.18V
7
37.222A
6.979A
6.962A
2.193A
524.538
88.686%
1215
30.6
42.23°C
0.990
12.235V
5.020V
3.318V
5.012V
591.453
49.89°C
115.17V
8
42.599A
7.976A
7.961A
2.398A
599.440
87.865%
1780
40.0
43.49°C
0.991
12.231V
5.018V
3.316V
5.000V
682.231
51.17°C
115.17V
9
48.395A
8.477A
8.473A
2.400A
674.412
86.994%
2310
45.1
44.47°C
0.991
12.229V
5.016V
3.315V
4.992V
775.244
52.29°C
115.17V
10
53.947A
8.982A
8.964A
3.015A
749.278
86.194%
2320
45.2
45.17°C
0.992
12.226V
5.014V
3.313V
4.971V
869.296
53.09°C
115.16V
11
60.076A
8.984A
8.967A
3.019A
824.091
85.105%
2330
45.4
46.52°C
0.992
12.224V
5.013V
3.312V
4.964V
968.327
54.48°C
115.16V
CL1
0.099A
12.013A
12.006A
0.000A
101.437
84.273%
560
10.5
43.21°C
0.977
12.248V
5.024V
3.321V
5.096V
120.367
52.88°C
115.21V
CL2
61.936A
1.003A
1.001A
1.001A
770.440
86.427%
2330
45.5
46.02°C
0.992
12.223V
5.021V
3.322V
5.031V
891.435
53.47°C
115.16V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.193A
0.491A
0.476A
0.195A
19.655
67.213%
0
| 6.0
0.892
12.233V
5.042V
3.336V
5.118V
29.243
115.19V
2
2.409A
0.990A
0.989A
0.391A
39.750
78.841%
0
| 6.0
0.942
12.234V
5.035V
3.332V
5.110V
50.418
115.20V
3
3.625A
1.480A
1.500A
0.585A
59.790
83.131%
0
| 6.0
0.962
12.236V
5.035V
3.332V
5.102V
71.923
115.20V
4
4.837A
1.986A
1.976A
0.783A
79.762
86.051%
0
| 6.0
0.971
12.238V
5.034V
3.330V
5.095V
92.692
115.20V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.1 mV
6.4 mV
6.7 mV
5.4 mV
Pass
20% Load
10.4 mV
6.1 mV
7.1 mV
6.1 mV
Pass
30% Load
13.2 mV
7.0 mV
9.5 mV
6.9 mV
Pass
40% Load
15.3 mV
7.0 mV
12.1 mV
7.4 mV
Pass
50% Load
17.3 mV
7.7 mV
12.4 mV
6.5 mV
Pass
60% Load
19.1 mV
8.3 mV
13.3 mV
7.8 mV
Pass
70% Load
20.8 mV
9.1 mV
14.4 mV
9.0 mV
Pass
80% Load
22.4 mV
9.2 mV
15.3 mV
11.0 mV
Pass
90% Load
24.4 mV
10.6 mV
18.1 mV
12.5 mV
Pass
100% Load
26.3 mV
11.1 mV
18.1 mV
12.9 mV
Pass
110% Load
28.4 mV
12.5 mV
19.4 mV
14.4 mV
Pass
Crossload 1
11.4 mV
10.1 mV
8.5 mV
7.6 mV
Pass
Crossload 2
26.4 mV
11.0 mV
20.0 mV
9.6 mV
Pass
The results above are not used in the certification process