This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
70.764%
0.042
5.105V
0.301
115.11V
2
0.087A
0.445
76.329%
0.079
5.104V
0.583
115.11V
3
0.532A
2.710
80.655%
0.284
5.094V
3.360
115.10V
4
1.002A
5.097
79.853%
0.353
5.086V
6.383
115.10V
5
1.502A
7.619
78.128%
0.388
5.073V
9.752
115.11V
6
3.002A
15.132
76.006%
0.437
5.041V
19.909
115.10V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.554A
1.975A
1.960A
0.987A
64.810
75.857%
1665
41.0
38.55°C
0.956
12.161V
5.062V
3.361V
5.070V
85.437
41.53°C
115.12V
2
8.149A
2.971A
2.952A
1.186A
129.781
83.201%
1685
41.2
38.83°C
0.975
12.139V
5.045V
3.348V
5.050V
155.985
42.34°C
115.12V
3
13.104A
3.478A
3.473A
1.384A
194.859
85.570%
1695
41.3
39.22°C
0.976
12.119V
5.030V
3.336V
5.037V
227.718
43.25°C
115.12V
4
18.067A
3.986A
3.967A
1.590A
259.751
86.509%
1695
41.3
39.87°C
0.979
12.099V
5.015V
3.324V
5.020V
300.258
44.32°C
115.11V
5
22.710A
5.001A
4.979A
1.796A
324.734
86.704%
1695
41.3
40.31°C
0.984
12.077V
4.996V
3.312V
5.005V
374.532
45.81°C
115.11V
6
27.370A
6.034A
6.000A
2.004A
389.747
86.450%
1695
41.3
41.10°C
0.987
12.055V
4.975V
3.298V
4.988V
450.834
47.57°C
115.11V
7
32.046A
7.059A
7.031A
2.210A
454.615
85.966%
1695
41.3
41.68°C
0.990
12.031V
4.957V
3.285V
4.969V
528.830
49.38°C
115.12V
8
36.748A
8.108A
8.072A
2.423A
519.649
85.308%
1695
41.3
42.59°C
0.992
12.007V
4.937V
3.270V
4.949V
609.144
51.62°C
115.11V
9
41.895A
8.640A
8.621A
2.429A
584.675
84.551%
1695
41.3
43.80°C
0.993
11.984V
4.922V
3.258V
4.937V
691.504
54.01°C
115.11V
10
46.800A
9.176A
9.150A
3.056A
649.515
83.581%
1695
41.3
44.89°C
0.994
11.962V
4.905V
3.245V
4.906V
777.107
56.82°C
115.11V
11
52.329A
9.200A
9.182A
3.064A
714.467
82.570%
1695
41.3
46.00°C
0.995
11.939V
4.894V
3.234V
4.893V
865.286
59.14°C
115.11V
CL1
0.099A
16.027A
16.004A
0.004A
133.061
78.070%
1695
41.3
43.84°C
0.976
12.115V
4.927V
3.304V
5.040V
170.438
52.24°C
115.12V
CL2
54.115A
1.004A
1.003A
1.003A
661.194
84.259%
1695
41.3
44.83°C
0.995
11.973V
4.977V
3.277V
4.977V
784.719
55.27°C
115.12V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.493A
0.471A
0.194A
19.697
54.519%
1590
39.6
0.928
12.179V
5.081V
3.374V
5.095V
36.129
115.13V
2
2.421A
0.980A
0.977A
0.391A
39.716
68.706%
1610
39.8
0.932
12.170V
5.074V
3.369V
5.088V
57.806
115.12V
3
3.655A
1.474A
1.485A
0.590A
59.913
75.316%
1635
40.3
0.961
12.163V
5.066V
3.363V
5.080V
79.549
115.12V
4
4.871A
1.976A
1.963A
0.785A
79.783
78.924%
1665
41.0
0.955
12.156V
5.060V
3.359V
5.069V
101.089
115.12V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.5 mV
30.6 mV
36.0 mV
8.5 mV
Pass
20% Load
7.4 mV
29.2 mV
31.2 mV
15.5 mV
Pass
30% Load
8.8 mV
26.4 mV
27.2 mV
11.1 mV
Pass
40% Load
10.5 mV
10.9 mV
11.5 mV
16.4 mV
Pass
50% Load
12.5 mV
11.6 mV
14.0 mV
13.4 mV
Pass
60% Load
14.3 mV
19.4 mV
23.5 mV
14.4 mV
Pass
70% Load
16.6 mV
25.6 mV
29.8 mV
15.4 mV
Pass
80% Load
20.1 mV
27.5 mV
36.5 mV
17.9 mV
Pass
90% Load
22.0 mV
24.9 mV
34.9 mV
18.8 mV
Pass
100% Load
26.1 mV
31.8 mV
38.6 mV
23.6 mV
Pass
110% Load
30.8 mV
32.8 mV
40.0 mV
23.6 mV
Pass
Crossload 1
16.9 mV
20.1 mV
30.5 mV
14.7 mV
Pass
Crossload 2
26.3 mV
37.9 mV
41.7 mV
15.5 mV
Pass
The results above are not used in the certification process