General Information
Fan Testing Instrument Technical Specifications
Test Equipment
Technical Specifications Table
Pressure and Airflow
General Performance
Download
Everflow F1214025BL
English
Deutsch
繁體中文
简体中文
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Everflow F1214025BL
Lab ID
EF13500131
Report: 24FN131A
Receipt Date:
Sep 4, 2024
Test Date:
Sep 18, 2024
Report Date:
Sep 19, 2024
Airflow Rating
Static Pressure Rating
Aristeidis Bitziopoulos, Laboratory General Manager
General Information
Fan Testing Instrument Technical Specifications
tech-specs
Manufacturer
Long Win Science & Technology Corporation
Model Number
LW-9266
Air Flow Rate
2.4 – 250 CFM
Accuracy of Air Flow Rage
< 3.5% INFS
Repeatability error
< 2%
Static pressure
0-20mmAq (100mmAq with the high static pressure throttle device)
Overall Dimensions
0.7 (W) x 2.2 (L) x 1.6 (H) m
Power Source
220VAC, 5A, Single Phase, 50/60Hz
Based on Standards
ISO 5801-2007, AMCA 210-0, ASHRAE 51-2007, IEC 61591-2005, GB/T 1236-200
Test Equipment
test-equip
Test Environment
Hemi-Anechoic Chamber with 6 dB(A) noise floor
Conditions
25(±2) degrees Celsius, 40-50% humidity
Sound Analyzer
Bruel & Kjaer 2270-S G4 & 2250-L G4
Microphone
Bruel & Kjaer Type 4955-A
Mic Calibrator
Bruel & Kjaer Type 4231
Data Logger
Picoscope TC-08
Technical Specifications Table
tech-specs2
Everflow
Modell
F1214025BL
Max Speed (RPM)
1560
Max Airflow (CFM)
73.94
Max Static Pressure (mmAq)
2.13
Max Fan Noise Level (dBA)
34.90
Fan Bearing Type
Two Ball
Fan Connector
2-Pin
Fan Max Current (A)
0.15
Fan Weight (gr)
168
Dimensions (W x H x D)
135x135x25
Fan daisy-chain connector
✗
Cable length (mm)
100
Pressure and Airflow
PWM
PQ Chart All Speed
PQ Chart 3.5V
PQ Chart 4V
PQ Chart 5V
PQ Chart 5.5V
PQ Chart 6V
PQ Chart 7V
PQ Chart 8V
PQ Chart 10V
PQ Chart 11V
PQ Chart 12V
General Performance
WTF
Fan Percentage RPM LongWin
Fan Percentage CFM
Fan Percentage Pressure
Fan Percentage Power
Fan Percentage Amps
Fan Percentage Noise
Fan Speed Noise
Fan Noise Speed
Everflow F1214025BL
ybenetics bietet die freiwilligen ETA- und Lambda-Zertifizierungsprogramme an, mit denen effiziente und leise Netzteile (PSU) beworben werden
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
www.cybenetics.com
-
info@cybenetics.com