CYS-CYSAB accreditation symbol, ISO/IEC 17025:2017
No. of Accred.: L152
TESTING
Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

GR X2 750

Report Number: 26PS3464A
Customer ID: 29
Lab ID: CG75003464

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.339%91.370%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9890.944
12V Step7.00W
5V/3.3V Step2.00W
Standby Power Consumption0.0694W0.1345W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB79.166%77.831%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

84858687888990919293Average efficiency (%)85.3289.9790.8890.0889.0586.6791.4992.7092.4491.880-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
84858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0.9590.9890.9940.9960.9960.8100.9420.9710.9750.9750-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78115V230V
0.780.800.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.78115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %215 / 21585.32%86.67%0.9590.810
20-<40 %333 / 33389.97%91.49%0.9890.942
40-<60 %331 / 33190.88%92.70%0.9940.971
60-<80 %332 / 33290.08%92.44%0.9960.975
80-100 %341 / 34189.05%91.88%0.9960.975
70-100 % (High-Load)504 / 50489.30%92.01%0.9960.975
All (published average)1552 / 155289.34%91.37%0.9890.944
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1552 (115V) and 1552 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)18.20dBA17.21dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 22.8 dB(A) at 115V and 21.7 dB(A) at 230V · loudest point 30.3 dB(A)
Efficiency 89.30% / 92.01% · power factor 0.996 / 0.975 (115V / 230V)
051015202530Average noise (dB(A))6.66.60-<20 %fan off 0%/0%6.66.620-<40 %fan off 0%/0%6.66.740-<60 %fan off 0%/0%13.814.960-<80 %fan off 0%/0%24.222.980-100 %fan off 0%/0%115V230V
051015202530Average noise (dB(A))6.66.60-<20 %off 0%/0%6.66.620-<40 %off 0%/0%6.66.740-<60 %off 0%/0%13.814.960-<80 %off 0%/0%24.222.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %6.6 (6.6)6.6 (6.6)0% / 0%
20-<40 %6.6 (6.6)6.6 (6.6)0% / 0%
40-<60 %6.6 (10.9)6.7 (13.5)0% / 0%
60-<80 %13.8 (22.9)14.9 (22.9)0% / 0%
80-100 %24.2 (30.3)22.9 (27.4)0% / 0%
70-100 % (High-Load)22.8 (30.3)21.7 (27.4)0% / 0%
All (published average)18.2 (30.3)17.2 (27.4)0% / 0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1552 (115V) and 1552 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%498 RPM · 6.6 dB(A) · 30.1 °C530 RPM · 8.9 dB(A) · 40.1 °C+2.3 dB(A)
20%505 RPM · 7.5 dB(A) · 30.2 °C539 RPM · 11.1 dB(A) · 40.6 °C+3.6 dB(A)
50%513 RPM · 7.5 dB(A) · 30.5 °C551 RPM · 10.9 dB(A) · 42.2 °C+3.4 dB(A)
100%1092 RPM · 27.0 dB(A) · 30.0 °C1574 RPM · 39.7 dB(A) · 45.2 °C+12.7 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%516 RPM · 7.5 dB(A) · 30.9 °C526 RPM · 7.5 dB(A) · 40.1 °C+0.0 dB(A)
20%512 RPM · 7.5 dB(A) · 30.1 °C536 RPM · 8.9 dB(A) · 40.3 °C+1.4 dB(A)
50%511 RPM · 7.5 dB(A) · 30.8 °C549 RPM · 11.1 dB(A) · 42.1 °C+3.6 dB(A)
100%1067 RPM · 26.3 dB(A) · 30.4 °C1615 RPM · 39.4 dB(A) · 45.4 °C+13.1 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load68.623%
Hold Up Time14.40ms
Power OK12.90ms
Power OK to DC Loss1.50ms
Test\Rail+12V5V3.3V5VSB
100ms12.0904.9893.2755.029
10ms11.9254.9653.2555.010
1ms11.6624.9183.2064.977
0.1ms11.5464.9163.1994.957

Section E: Information about DUT

Product Identification Details
BrandCougar
ModelGR X2 750
OEM/ODMRSY
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)6-10
Rated Frequency (Hz)50-60
Rated Power (W)750
Operating Temperature (Continuous Full Load) (°C)10 - 42
TypeATX12V
Cable DesignFully Modular
WarrantyNo info
Cybenetics
Dimensions (W x H x D)150 x 86 x 140 mm
Weight1232 g
Cooling120mm Sleeve Bearing Fan (Globe Fan S1202512L)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDCG75003464
Date of receiptOct 5, 2026
Testing DateOct 9, 2026
Report Issued DateOct 11, 2026
Engineer NameEfstathios Papadopoulos
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (600mm) 1 1 18-22AWG Tinned Copper
4+4 pin EPS12V (700mm) 2 2 18AWG Tinned Copper
6+2 pin PCIe (600mm) 1 1 18AWG Tinned Copper
6+2 pin PCIe (550mm+150mm) 1 2 18AWG Tinned Copper
12+4 pin PCIe (600mm) (450W) 1 1 16-24AWG Copper
SATA (465mm+145mm+145mm) / 4-pin Molex (+145mm) 2 6 / 2 18AWG Tinned Copper
AC Power Cord (1380mm) - C13 coupler 1 1 18AWG -

Protection Features(Non-accredited measurements)

Over Voltage Protection✓
Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) RSY
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor 2.5D-11 (2.5 Ohm) & Relay
Bridge Rectifier HY Electronic GBU1506 (600V, 15A @ 25°C)
APFC MOSFETs 2x Super Semi SSF60R190S2E (600V, 12.6A @ 100°C, Rds(on): 0.19Ohm)
APFC Boost Diode Diodes Incorporated DSC08A065 (650V, 8A @ 25°C)
Bulk Cap(s) Rubycon (420V, 330uF, 2000h @ 105°C, MXH)
Main Switchers 4x Shenzhen SIF13N50C (500V, 8A @ 100°C, Rds(on): 0.55Ohm)
APFC Controller Texas Instruments UCC28180 & Sync Power SPN5003 (reducing no-load consumption)
Resonant Controller Texas Instruments UCC25600
Topology Primary side: APFC, Full-Bridge & LLC Resonant Converter Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 4x Maplesemi SLP130N04T (40V, 84A @ 100°C, Rds(on): 2.5mOhm)
5V & 3.3V DC-DC Converters: 4x Infineon BSC0906NS (30V, 63A @ 25°C, Rds(on): 4.5mOhm) PWM Controller(s): 2x Anpec APW7164
Filtering Capacitors Electrolytic: 21x Vent (3,000h @ 105°C, CD288HJ) Polymer: 9x NJcon
Supervisor IC 1x INFSitronix IN1S315I
Fan Model Globe Fan S1202512L (120mm, 12V, 0.18A, Sleeve Bearing Fan)
5VSB Circuit
Rectifiers Pingwei PS1060L
PWM controller Safety-Chip SC2583

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB