CYS-CYSAB accreditation symbol, ISO/IEC 17025:2017
No. of Accred.: L152
TESTING
Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

Elite Platinum 1000

Report Number: 26PS3463A
Customer ID: 27
Lab ID: CM10003463

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)90.076%91.924%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9890.964
12V Step10.00W
5V/3.3V Step2.00W
Standby Power Consumption0.0479W0.0768W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB81.501%81.074%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

85868788899091929394Average efficiency (%)86.5891.2991.4990.7289.4587.2292.6493.3193.0092.280-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
85868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
0.860.880.900.920.940.960.981.00Average power factor0.9720.9880.9910.9940.9960.8930.9600.9770.9840.9880-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
0.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %233 / 23386.58%87.22%0.9720.893
20-<40 %310 / 31091.29%92.64%0.9880.960
40-<60 %310 / 31091.49%93.31%0.9910.977
60-<80 %310 / 31090.72%93.00%0.9940.984
80-100 %317 / 31789.45%92.28%0.9960.988
70-100 % (High-Load)472 / 47289.78%92.47%0.9950.987
All (published average)1480 / 148090.08%91.92%0.9890.964
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)19.50dBA19.22dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 23.4 dB(A) at 115V and 23.5 dB(A) at 230V · loudest point 26.3 dB(A)
Efficiency 89.78% / 92.47% · power factor 0.995 / 0.987 (115V / 230V)
051015202530Average noise (dB(A))<6.0<6.00-<20 %fan off 100%/100%<6.0<6.020-<40 %fan off 100%/100%14.710.240-<60 %fan off 82%/94%21.120.160-<80 %fan off 30%/39%24.124.480-100 %fan off 3%/3%115V230V
051015202530Average noise (dB(A))<6.0<6.00-<20 %off 100%/100%<6.0<6.020-<40 %off 100%/100%14.710.240-<60 %off 82%/94%21.120.160-<80 %off 30%/39%24.124.480-100 %off 3%/3%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)100% / 100%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)100% / 100%
40-<60 %14.7 (23.5)10.2 (24.8)82% / 94%
60-<80 %21.1 (23.5)20.1 (24.8)30% / 39%
80-100 %24.1 (26.3)24.4 (26.3)3% / 3%
70-100 % (High-Load)23.4 (26.3)23.5 (26.3)8% / 12%
All (published average)19.5 (26.3)19.2 (26.3)61% / 65%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1480 (115V) and 1480 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 47.6 °C0 RPM · <6.0 dB(A) · 53.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 48.4 °C0 RPM · <6.0 dB(A) · 53.4 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 54.6 °C0 RPM · <6.0 dB(A) · 63.8 °Cfan off in both
100%767 RPM · 22.9 dB(A) · 31.8 °C1256 RPM · 33.3 dB(A) · 45.3 °C+10.4 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 45.7 °C0 RPM · <6.0 dB(A) · 46.8 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 44.7 °C0 RPM · <6.0 dB(A) · 48.7 °Cfan off in both
50%0 RPM · <6.0 dB(A) · 46.1 °C0 RPM · <6.0 dB(A) · 53.6 °Cfan off in both
100%766 RPM · 22.9 dB(A) · 34.8 °C1258 RPM · 33.3 dB(A) · 45.4 °C+10.4 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load70.718%
Hold Up Time19.80ms
Power OK15.50ms
Power OK to DC Loss4.30ms
Test\Rail+12V5V3.3V5VSB
100ms12.0184.9813.2545.057
10ms11.5864.9553.2275.005
1ms11.4384.9413.2144.981
0.1ms11.2544.9173.1984.948

Section E: Information about DUT

Product Identification Details
BrandCooler Master
ModelElite Platinum 1000
OEM/ODMXHY Power
Serial NumberCM1531000F24052003600075
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)6-13
Rated Frequency (Hz)50-60
Rated Power (W)1000
Operating Temperature (Continuous Full Load) (°C)0 - 50
TypeATX12V
Cable DesignFully Modular
Warranty12 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 140mm
Weight1.61 kg (3.55 lb)
Cooling120mm Rifle Bearing Fan (DF1202512RFMN)
Semi-Passive Operation✓
Cybenetics Testing Information
Lab IDCM10003463
Date of receiptSep 29, 2026
Testing DateOct 23, 2026
Report Issued DateNov 5, 2026
Engineer NameEfstathios Papadopoulos
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 24 pin (600mm) 1 1 18-20AWG Tinned Copper
4+4 pin EPS12V (700mm) 1 1 18AWG Tinned Copper
8 pin EPS12V (700mm) 1 1 18AWG Tinned Copper
6+2 pin PCIe (600mm) 3 3 18AWG Tinned Copper
12+4 pin PCIe (600mm) (600W) 1 1 16-24AWG Tinned Copper
SATA / 4-pin Molex (410mm+120mm) / (+120mm) 3 6/3 18AWG Tinned Copper
AC Power Cord (1370mm) - C13 coupler 1 1 16AWG -

Protection Features(Non-accredited measurements)

Over Voltage Protection✓
Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) Xin Hui Yuan Technology
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection

1x NTC Thermistor  MF72 5D-15 (5.0 Ohm @ 25°C) & Relay

Bridge Rectifier 2x Yangzhou Yangjie GBUL2506 (600V, 25A @ 125°C)
APFC MOSFETs 2x CR Micro CRJT99N65G2BF (650V, 20A @ 100°C, Rds(on): 0.103Ohm)
APFC Boost Diode 1x CR Micro CRXI06D065G3  (650V, 6A @ 163°C)
Bulk Cap(s)


1x Rubycon (420V, 680uF, 2000h @ 105°C, MXE )


Main Switchers 4x Ncepower NCE65TF099T (650V, 24A@ 100°C, Rds(on): 0.099Ohm)

APFC Controller

Champion CM6500UNX

Resonant Controller Champion CM6901T6X
Topology

Primary side: APFC, Full-Bridge & LLC Resonant Converter
Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters

Secondary Side
+12V MOSFETs 4x U300N06
5V & 3.3V

DC-DC Converters: 6x CR Micro CRSM035N03L6Z  (30V, 54A @ 100°C, Rds(on): 3.5mOhm)
PWM Controller(s): Atkic AT8852Z

Filtering Capacitors

Electrolytic:
3x Nippon Chemi-con (@ 105°C, W)
6x Rubycon (4,000-10,000h @ 105°C, YXJ)
1x Rubycon (6,000-10,000h @ 105°C, ZLH)
Polymer:
20x Nichicon FPCAP

Supervisor IC IN1T7031-SDG
Fan Power Switch B772 PNP Transistor
Fan Model DF1202512RFMN (120mm, 12V, 0.20A, Rifle Bearing Fan)
5VSB Circuit
Rectifier Dongke DK5V60R10S (60V, 10mΩ)
Standby PWM Controller ExcellianceMOS EM8569C

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB