CYS-CYSAB accreditation symbol, ISO/IEC 17025:2017
No. of Accred.: L152
TESTING
Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

C1200 Platinum

Report Number: 26PS3445A
Customer ID: 85
Lab ID: NZ12003445

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)90.294%92.384%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9820.946
12V Step11.00W
5V/3.3V Step2.50W
Standby Power Consumption0.0590W0.0856W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB84.655%84.626%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

85868788899091929394Average efficiency (%)86.7291.9391.7690.8089.3687.7893.2993.7493.3692.590-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
85868788899091929394Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 85115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9510.9750.9870.9920.9940.8510.9410.9630.9730.9780-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %245 / 24586.72%87.78%0.9510.851
20-<40 %328 / 32891.93%93.29%0.9750.941
40-<60 %327 / 32791.76%93.74%0.9870.963
60-<80 %328 / 32890.80%93.36%0.9920.973
80-100 %331 / 33189.36%92.59%0.9940.978
70-100 % (High-Load)497 / 49789.74%92.80%0.9940.977
All (published average)1559 / 155990.29%92.38%0.9820.946
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)21.96dBA21.98dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 26.8 dB(A) at 115V and 26.8 dB(A) at 230V · loudest point 32.9 dB(A)
Efficiency 89.74% / 92.80% · power factor 0.994 / 0.977 (115V / 230V)
05101520253035Average noise (dB(A))<6.0<6.00-<20 %fan off 100%/100%<6.0<6.020-<40 %fan off 99%/99%6.6<6.040-<60 %fan off 33%/32%17.217.260-<80 %fan off 0%/0%28.328.380-100 %fan off 0%/0%115V230V
0102030Average noise (dB(A))<6.0<6.00-<20 %off 100%/100%<6.0<6.020-<40 %off 99%/99%6.6<6.040-<60 %off 33%/32%17.217.260-<80 %off 0%/0%28.328.380-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)100% / 100%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)99% / 99%
40-<60 %6.6 (22.0)<6.0 (7.6)33% / 32%
60-<80 %17.2 (22.0)17.2 (22.0)0% / 0%
80-100 %28.3 (32.9)28.3 (32.9)0% / 0%
70-100 % (High-Load)26.8 (32.9)26.8 (32.9)0% / 0%
All (published average)22.0 (32.9)22.0 (32.9)44% / 43%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1559 (115V) and 1559 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 32.7 °C0 RPM · <6.0 dB(A) · 42.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 33.3 °C0 RPM · <6.0 dB(A) · 44.2 °Cfan off in both
50%803 RPM · 24.1 dB(A) · 31.0 °C392 RPM · <6.0 dB(A) · 42.2 °C-
100%1067 RPM · 33.2 dB(A) · 30.8 °C1506 RPM · 42.9 dB(A) · 45.8 °C+9.7 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 35.6 °C0 RPM · <6.0 dB(A) · 55.1 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 30.8 °C0 RPM · <6.0 dB(A) · 56.0 °Cfan off in both
50%379 RPM · <6.0 dB(A) · 30.1 °C396 RPM · <6.0 dB(A) · 42.2 °C<6.0 in both
100%1070 RPM · 33.2 dB(A) · 30.8 °C1323 RPM · 39.3 dB(A) · 45.5 °C+6.1 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load77.242%
Hold Up Time19.80ms
Power OK17.10ms
Power OK to DC Loss2.70ms
Test\Rail+12V5V3.3V5VSB
100ms11.8414.9973.2484.969
10ms11.3244.9343.1964.916
1ms11.1294.9143.1714.896
0.1ms11.4174.9323.1944.912

Section E: Information about DUT

Product Identification Details
BrandNZXT
ModelC1200 Platinum
OEM/ODMHEC
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)7-15
Rated Frequency (Hz)50-60
Rated Power (W)1200
Operating Temperature (Continuous Full Load) (°C)0 - 50
TypeATX12V
Cable DesignFully Modular
Warranty10 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 150 mm
Weight1.90 kg (4.18 lb)
Cooling140mm Fluid Dynamic Bearing Fan (HA1425H12SF-Z)
Semi-Passive Operation✓ (selectable)
Cybenetics Testing Information
Lab IDNZ12003445
Date of receiptSep 15, 2026
Testing DateOct 9, 2026
Report Issued DateOct 9, 2026
Engineer NameEfstathios Papadopoulos
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (600mm) 1 1 16-18AWG Tinned Copper
4+4 pin EPS12V (700mm) 1 1 18AWG Tinned Copper
8 pin EPS12V (700mm) 1 1 18AWG Tinned Copper
6+2 pin PCIe (650mm) 4 4 16AWG Tinned Copper
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG Tinned Copper
SATA (500mm+150mm+150mm+150mm) 2 8 18AWG Tinned Copper

Protection Features(Non-accredited measurements)

Over Voltage Protection✓
Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) HEC
PCB Type Double-Sided
Primary Side
Transient Filter 2x Y caps, 3x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor SCK-205R0 (5Ohm) & Relay
Bridge Rectifier(s) 2x  GBUE2560P  (600V, 25A @ 140°C)
APFC MOSFETs 3x Infineon  IPA60R080P7  (650V, 23A @ 100°C, Rds(on): 0.08Ohm)
APFC Boost Diode Wolfspeed C6D10065A  (650V, 10A @ 155°C)
Bulk Cap(s) 1x Rubycon (450V, 560uF, 3,000h @ 105°C,  MXK )
1x Rubycon (450V, 470uF, 3,000h @ 105°C,  MXT )
Main Switchers 2x GP47S60YERD (600V, 16A @ 100°C, Rds(on): 0.35Ohm)
APFC  Controller Champion  CM6500UNX &
Champion CM03AX (reducing no load consumption)
Resonant Controller Champion CU6901VABN
Topology Primary side: APFC, Half-Bridge & LLC Resonant converter
Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs

No Info

5V & 3.3V DC-DC Converters: 4x 2R5SN04C
PWM Controller(s): Anpec APW7159C
Filtering Capacitors

Electrolytic:
3x Nippon Chemi-con (2~4,000h @ 105°C, W)
2x Nippon Chemi-con (2~4,000h @ 105°C, KZE )
1x Rubycon (6~10,000h @ 105°C, ZLH )
1x Rubycon (4~10,000h @ 105°C, YXJ )
Polymer:
31x Nippon Chemi-con

Supervisor IC INFSitronix IN1T415I-SCG 
Fan Controller Nuvoton MS51FB9AE
Fan Model Hong Hua HA1425H12SF-Z (140mm, 12V, 0.50A, Fluid Dynamic Bearing Fan)
5VSB
Rectification IC UR1013P
Standby PWM Controller Excelliance MOS EM8569D

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB