Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

CX550 (ATXv3.1)

Report Number: 26PS3298A
Customer ID: 28
Lab ID: CR55003298

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)87.132%89.096%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9930.964
12V Step5.00W
5V/3.3V Step2.00W
Standby Power Consumption0.0512W0.0858W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB82.271%81.564%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

79808182838485868788899091Average efficiency (%)80.2987.0388.7888.5487.5881.0488.6490.6490.8090.300-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 79115V230V
79808182838485868788899091Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 79115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0.9770.9890.9960.9980.9980.8600.9540.9770.9850.9890-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %171 / 17180.29%81.04%0.9770.860
20-<40 %341 / 34187.03%88.64%0.9890.954
40-<60 %341 / 34188.78%90.64%0.9960.977
60-<80 %341 / 34188.54%90.80%0.9980.985
80-100 %354 / 35487.58%90.30%0.9980.989
70-100 % (High-Load)521 / 52187.84%90.44%0.9980.988
All (published average)1548 / 154887.13%89.10%0.9930.964
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1548 (115V) and 1548 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 550 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)33.50dBA33.48dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 37.8 dB(A) at 115V and 37.8 dB(A) at 230V · loudest point 41.7 dB(A)
Efficiency 87.84% / 90.44% · power factor 0.998 / 0.988 (115V / 230V)
051015202530354045Average noise (dB(A))20.920.90-<20 %fan off 0%/0%20.920.920-<40 %fan off 0%/0%24.124.340-<60 %fan off 0%/0%32.432.160-<80 %fan off 0%/0%38.938.980-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))20.920.90-<20 %off 0%/0%20.920.920-<40 %off 0%/0%24.124.340-<60 %off 0%/0%32.432.160-<80 %off 0%/0%38.938.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %20.9 (20.9)20.9 (20.9)0% / 0%
20-<40 %20.9 (20.9)20.9 (20.9)0% / 0%
40-<60 %24.1 (31.7)24.3 (31.7)0% / 0%
60-<80 %32.4 (41.0)32.1 (41.0)0% / 0%
80-100 %38.9 (41.7)38.9 (41.7)0% / 0%
70-100 % (High-Load)37.8 (41.7)37.8 (41.7)0% / 0%
All (published average)33.5 (41.7)33.5 (41.7)0% / 0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1548 (115V) and 1548 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 550 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%734 RPM · 20.7 dB(A) · 30.2 °C762 RPM · 20.9 dB(A) · 40.4 °C+0.2 dB(A)
20%737 RPM · 20.8 dB(A) · 30.7 °C760 RPM · 20.9 dB(A) · 40.8 °C+0.1 dB(A)
50%738 RPM · 20.8 dB(A) · 30.4 °C1051 RPM · 29.5 dB(A) · 42.4 °C+8.7 dB(A)
100%1673 RPM · 42.2 dB(A) · 30.0 °C2103 RPM · 48.7 dB(A) · 45.4 °C+6.5 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%730 RPM · 20.5 dB(A) · 30.1 °C763 RPM · 20.8 dB(A) · 40.2 °C+0.3 dB(A)
20%731 RPM · 20.6 dB(A) · 30.4 °C764 RPM · 20.8 dB(A) · 40.8 °C+0.2 dB(A)
50%735 RPM · 20.7 dB(A) · 30.1 °C1048 RPM · 29.5 dB(A) · 42.3 °C+8.8 dB(A)
100%1747 RPM · 43.4 dB(A) · 30.3 °C2110 RPM · 48.7 dB(A) · 45.7 °C+5.3 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load64.114%
Hold Up Time14.80ms
Power OK11.90ms
Power OK to DC Loss2.90ms
Test\Rail+12V5V3.3V5VSB
100ms11.8644.9473.2375.000
10ms11.7384.9293.2194.995
1ms11.6924.9233.2104.994
0.1ms11.6794.9333.2214.997

Section E: Information about DUT

Product Identification Details
BrandCorsair
ModelCX550 (ATXv3.1)
OEM/ODMHEC
Serial Number4654
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)5-10
Rated Frequency (Hz)47-63
Rated Power (W)550
Operating Temperature (Continuous Full Load) (°C)0 - 40
TypeATX12V
Cable DesignFixed cables
Warranty5 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 125mm
Weight1.58kg (3.48 lb)
Cooling120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDCR55003298
Date of receiptMay 6, 2026
Testing DateMay 28, 2026
Report Issued DateMay 28, 2026
Engineer NameIoannis Kalyviotis
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Captive Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 24 pin (610mm) 1 1 18-20AWG Tinned Copper
4+4 pin EPS12V (530mm) 1 1 18AWG Tinned Copper
6+2 pin PCIe (520mm+100mm) 1 2 18AWG Tinned Copper
SATA (400mm+100mm+100mm) 1 3 18AWG Tinned Copper
4-pin Molex (420mm+100mm) 1 2 18AWG Tinned Copper
Modular Cables
AC Power Cord (1400mm) - C13 coupler 1 1 18AWG -

Protection Features(Non-accredited measurements)

Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) HEC
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV, 1x Power Integrations CAP200DG (X Capacitor Discharge IC)
Inrush Protection NTC Thermistor NTC3D-15 (3Ohm @ 25°C)
Bridge Rectifier(s)
MCC GBU10K (800V, 10A @ 100°C)
APFC MOSFETs
2x PY 15N50TFS
APFC Boost Diode
Hestia Power H3S065A004 (650V, 14A @ 25°C)
Bulk Cap(s)
Teapo (400V, 270uF, 2,000h @ 105°C, LG)
Main Switchers
2x CRMicro CS13N50F A9R (500V, 13A @ 25°C, Rds(on): 0.5Ohm)
PFC/LLC Combo Controller
Topology
Primary side: APFC, Half-Bridge & LLC Resonant Converter
Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 4x Jiangsu Changjing Electronics Technology CJAC2R5SN04C (40V, 130A @ 25°C, Rds(on): 2.5mOhm)
SR Controller MPS MP6924B
5V & 3.3V DC-DC Converters: 2x Potens PDC39F2BX (30V, 120A @ 25°C, Rds(on): 2.95mOhm)
2x Potens PDC3906Z (30V, 60A @ 25°C, Rds(on): 6mOhm)
PWM Controller(s): 2x ANPEC APW7164
Filtering Capacitors

Electrolytic:
Nippon Chemi-Con (2,000-5,000h @ 105°C, KZE)
13x Teapo (1,000-3,000h @ 105°C, SC)
Polymer:
5x Teapo (FG)

Supervisor IC IN1T70312-SDG
Fan Controller 1x 2SB1424 PNP transistor
Fan Model Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier
PS1060L (60V, 10A)
Standby PWM Controller Grenergy GR9877BU

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB