Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

CX650 (ATXv3.1)

Report Number: 26PS3297A
Customer ID: 28
Lab ID: CR65003297

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)87.406%89.745%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9910.955
12V Step6.00W
5V/3.3V Step2.00W
Standby Power Consumption0.0538W0.0985W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB81.755%80.838%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

818283848586878889909192Average efficiency (%)82.3588.2289.0888.3686.9184.3189.9591.1590.9290.110-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 81115V230V
818283848586878889909192Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 81115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9740.9880.9940.9950.9960.8440.9470.9710.9800.9850-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %195 / 19582.35%84.31%0.9740.844
20-<40 %340 / 34088.22%89.95%0.9880.947
40-<60 %332 / 33289.08%91.15%0.9940.971
60-<80 %339 / 33988.36%90.92%0.9950.980
80-100 %343 / 34386.91%90.11%0.9960.985
70-100 % (High-Load)509 / 50987.29%90.33%0.9960.984
All (published average)1549 / 154987.41%89.75%0.9910.955
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1549 (115V) and 1549 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 650 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)36.81dBA35.89dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 41.3 dB(A) at 115V and 40.4 dB(A) at 230V · loudest point 48.7 dB(A)
Efficiency 87.29% / 90.33% · power factor 0.996 / 0.984 (115V / 230V)
05101520253035404550Average noise (dB(A))16.417.60-<20 %fan off 0%/0%19.218.020-<40 %fan off 0%/0%28.026.440-<60 %fan off 0%/0%34.434.360-<80 %fan off 0%/0%42.641.680-100 %fan off 0%/0%115V230V
01020304050Average noise (dB(A))16.417.60-<20 %off 0%/0%19.218.020-<40 %off 0%/0%28.026.440-<60 %off 0%/0%34.434.360-<80 %off 0%/0%42.641.680-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %16.4 (17.3)17.6 (19.5)0% / 0%
20-<40 %19.2 (25.4)18.0 (23.1)0% / 0%
40-<60 %28.0 (32.2)26.4 (32.2)0% / 0%
60-<80 %34.4 (42.5)34.3 (41.8)0% / 0%
80-100 %42.6 (48.7)41.6 (44.5)0% / 0%
70-100 % (High-Load)41.3 (48.7)40.4 (44.5)0% / 0%
All (published average)36.8 (48.7)35.9 (44.5)0% / 0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1549 (115V) and 1549 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 650 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%621 RPM · 17.0 dB(A) · 29.9 °C757 RPM · 21.0 dB(A) · 40.4 °C+4.0 dB(A)
20%635 RPM · 17.3 dB(A) · 30.5 °C846 RPM · 24.3 dB(A) · 40.8 °C+7.0 dB(A)
50%827 RPM · 24.0 dB(A) · 30.8 °C1244 RPM · 35.0 dB(A) · 42.1 °C+11.0 dB(A)
100%2093 RPM · 48.6 dB(A) · 31.0 °C2018 RPM · 47.0 dB(A) · 45.2 °C-1.6 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%607 RPM · 16.7 dB(A) · 30.7 °C760 RPM · 20.9 dB(A) · 40.1 °C+4.2 dB(A)
20%653 RPM · 17.7 dB(A) · 30.4 °C910 RPM · 26.0 dB(A) · 40.8 °C+8.3 dB(A)
50%827 RPM · 24.0 dB(A) · 30.5 °C1243 RPM · 35.0 dB(A) · 42.4 °C+11.0 dB(A)
100%2092 RPM · 48.6 dB(A) · 30.2 °C2099 RPM · 48.7 dB(A) · 45.5 °C+0.1 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load65.018%
Hold Up Time14.10ms
Power OK11.70ms
Power OK to DC Loss2.40ms
Test\Rail+12V5V3.3V5VSB
100ms11.8214.9273.2465.020
10ms11.4624.9023.2135.009
1ms11.4424.8883.1965.006
0.1ms11.3314.8973.2145.003

Section E: Information about DUT

Product Identification Details
BrandCorsair
ModelCX650 (ATXv3.1)
OEM/ODMHEC
Serial Number4655
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)5-10
Rated Frequency (Hz)47-63
Rated Power (W)650
Operating Temperature (Continuous Full Load) (°C)0 - 40
TypeATX12V
Cable DesignFixed cables
Warranty5 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 125mm
Weight1.70 kg (3.75 lb)
Cooling120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDCR65003297
Date of receiptMay 6, 2026
Testing DateMay 25, 2026
Report Issued DateMay 28, 2026
Engineer NameIoannis Kalyviotis
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Captive Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 24 pin (610mm) 1 1 16-20AWG Tinned Copper
8 pin EPS12V (530mm) / 4+4 pin EPS12V (+100mm) 1 1 / 1 18AWG Tinned Copper
6+2 pin PCIe (520mm+100mm) 1 2 18AWG Tinned Copper
12+2 pin PCIe (630mm) (450W) 1 1 16-24AWG Tinned Copper
SATA (400mm+100mm+100mm) 1 3 18AWG Tinned Copper
4-pin Molex (420mm+100mm) 1 2 18AWG Tinned Copper
Modular Cables
AC Power Cord (1400mm) - C13 coupler 1 1 18AWG -

Protection Features(Non-accredited measurements)

Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) HEC
PCB Type Double-Sided
Primary Side
Transient Filter 5x Y caps, X caps (1x 0.68uF X2 legible, others not), 2x CM chokes, 1x MOV (marking not legible)
Inrush Protection NTC Thermistor 3D-15 (3 Ohm @ 25°C)
Bridge Rectifier(s) 1x MCC GBU10K (800V, 10A @ 100°C)
APFC MOSFETs 2x Pingwei PWE180N65MFS (650V, 13A @ 100°C, Rds(on): 0.18 Ohm)
APFC Boost Diode 1x Hestia Power H3S065A004 (marking partly legible)
Bulk Cap(s) 1x Teapo (400V, 330uF, 2,000h @ 105°C, LG )
Main Switchers 2x CRMicro CS13N50F A9R (500V, 13A @ 25°C, Rds(on): 0.5 Ohm)
PFC/LLC Combo Controller Monolithic Power Systems HR1280
Topology Primary side: APFC, Half-Bridge & LLC Resonant converter
Secondary side: Synchronous Rectification & DC-DC converters
Secondary Side
+12V MOSFETs 4x (marking not legible)
SR Controller MPS MP6924B
5V & 3.3V DC-DC Converters: Potens Semiconductor PDC39F2BX, other DC-DC MOSFETs not legible
PWM Controller(s): 2x ANPEC APW7164
Filtering Capacitors

Electrolytic:
Teapo (1-3,000h @ 105°C, SC ),
1x unidentified (marking not legible)
Polymer:
5x (FG, maker not printed)

Supervisor IC IN1T70312-SDG
Fan Model Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier 1x PS1060L SBR (60V, 10A)
Standby PWM Controller Grenergy GR9877BU

Photos

Top side
Top side
Power specifications label
Power specifications label
FaN
FaN
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB