Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

CX750 (ATXv3.1)

Report Number: 26PS3296A
Customer ID: 28
Lab ID: CR75003296

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)88.363%90.617%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9940.968
12V Step7.00W
5V/3.3V Step2.50W
Standby Power Consumption0.0497W0.0969W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB81.242%81.394%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

8283848586878889909192Average efficiency (%)83.3288.8989.9189.3488.2184.7890.4991.9391.9591.400-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
8283848586878889909192Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 82115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0.9790.9940.9970.9970.9980.8760.9630.9820.9880.9920-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
0.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.84115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %185 / 18383.32%84.78%0.9790.876
20-<40 %321 / 32188.89%90.49%0.9940.963
40-<60 %321 / 32389.91%91.93%0.9970.982
60-<80 %322 / 32289.34%91.95%0.9970.988
80-100 %328 / 32888.21%91.40%0.9980.992
70-100 % (High-Load)490 / 49088.51%91.56%0.9970.991
All (published average)1477 / 147788.36%90.62%0.9940.968
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1477 (115V) and 1477 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)38.03dBA36.67dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 42.4 dB(A) at 115V and 41.1 dB(A) at 230V · loudest point 46.5 dB(A)
Efficiency 88.51% / 91.56% · power factor 0.997 / 0.991 (115V / 230V)
05101520253035404550Average noise (dB(A))23.123.10-<20 %fan off 0%/0%23.423.620-<40 %fan off 0%/0%29.528.040-<60 %fan off 0%/0%37.035.260-<80 %fan off 0%/0%43.542.280-100 %fan off 0%/0%115V230V
01020304050Average noise (dB(A))23.123.10-<20 %off 0%/0%23.423.620-<40 %off 0%/0%29.528.040-<60 %off 0%/0%37.035.260-<80 %off 0%/0%43.542.280-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %23.1 (23.1)23.1 (23.1)0% / 0%
20-<40 %23.4 (28.0)23.6 (28.0)0% / 0%
40-<60 %29.5 (35.6)28.0 (34.0)0% / 0%
60-<80 %37.0 (43.4)35.2 (42.5)0% / 0%
80-100 %43.5 (46.5)42.2 (44.9)0% / 0%
70-100 % (High-Load)42.4 (46.5)41.1 (44.9)0% / 0%
All (published average)38.0 (46.5)36.7 (44.9)0% / 0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1477 (115V) and 1477 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%795 RPM · 23.0 dB(A) · 29.8 °C824 RPM · 24.0 dB(A) · 40.5 °C+1.0 dB(A)
20%801 RPM · 23.2 dB(A) · 30.2 °C825 RPM · 24.0 dB(A) · 40.8 °C+0.8 dB(A)
50%864 RPM · 24.6 dB(A) · 30.7 °C1221 RPM · 34.5 dB(A) · 42.5 °C+9.9 dB(A)
100%1979 RPM · 46.5 dB(A) · 30.6 °C2103 RPM · 48.7 dB(A) · 45.1 °C+2.2 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%796 RPM · 23.0 dB(A) · 30.6 °C825 RPM · 24.0 dB(A) · 40.3 °C+1.0 dB(A)
20%799 RPM · 23.1 dB(A) · 29.9 °C827 RPM · 24.0 dB(A) · 40.8 °C+0.9 dB(A)
50%802 RPM · 23.2 dB(A) · 29.9 °C1221 RPM · 34.5 dB(A) · 42.1 °C+11.3 dB(A)
100%1944 RPM · 46.3 dB(A) · 30.6 °C2105 RPM · 48.7 dB(A) · 45.5 °C+2.4 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load67.418%
Hold Up Time13.11ms
Power OK11.01ms
Power OK to DC Loss2.10ms
Test\Rail+12V5V3.3V5VSB
100ms11.8084.9453.2215.019
10ms11.4624.9193.1915.006
1ms11.3624.9043.1754.999
0.1ms11.2194.8993.1814.992

Section E: Information about DUT

Product Identification Details
BrandCorsair
ModelCX750 (ATXv3.1)
OEM/ODMHEC
Serial Number4656
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)5-10
Rated Frequency (Hz)47-63
Rated Power (W)750
Operating Temperature (Continuous Full Load) (°C)0 - 40
TypeATX12V
Cable DesignFixed cables
Warranty5 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 125mm
Weight1.85 kg (4.08 lb)
Cooling120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDCR75003296
Date of receiptMay 6, 2026
Testing DateMay 21, 2026
Report Issued DateMay 28, 2026
Engineer NameIoannis Kalyviotis
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Captive Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 24 pin (610mm) 1 1 16-20AWG Tinned Copper
8 pin EPS12V (530mm) / 4+4 pin EPS12V (+100mm) 1 1 / 1 18AWG Tinned Copper
6+2 pin PCIe (520mm+100mm) 1 2 18AWG Tinned Copper
6+2 pin PCIe (640mm) 1 1 18AWG Tinned Copper
12+2 pin PCIe (630mm) (600W) 1 1 16-24AWG Tinned Copper
SATA (400mm+100mm+100mm) 1 3 18AWG Tinned Copper
4-pin Molex (420mm+100mm) 1 2 18AWG Tinned Copper
Modular Cables
AC Power Cord (1400mm) - C13 coupler 1 1 18AWG -

Protection Features(Non-accredited measurements)

Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) HEC
PCB Type Double-Sided
Primary Side
Transient Filter 5x Y caps, 3x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor 3D-15 (3Ohm @ 25°C)
Bridge Rectifier(s) 1x MCC GBU15K (800V, 15A @ 100°C)
APFC MOSFETs 2x Pingwei PWE180N65MFS (650V, 13A @ 100°C, Rds(on): 0.18 Ohm)
APFC Boost Diode Hestia Power H3S065A006 (650V, 6A @ 156°C)
Bulk Cap(s) 1x Teapo (400V, 390uF, 2,000h @ 105°C, LG )
Main Switchers 2x Pingwei PWE180N65MFS (650V, 13A @ 100°C, Rds(on): 0.18 Ohm)
APFC/LLC Controller Combo Monolithic Power Systems HR1280
Topology Primary side: APFC, Half-Bridge & LLC Resonant converter
Secondary side: Synchronous Rectification & DC-DC converters
Secondary Side
+12V MOSFETs 4x Pingwei PWC012N04ES (40V, 132A @ 100°C, Rds(on): 1.2 mOhm)
SR Controller MPS MP6924B
5V & 3.3V DC-DC Converters: 2x Potens Semiconductor PDC39F2BX (30V, 76A @ 100°C, Rds(on): 2.95mOhm)
2x CHANG JING CJAC2R5SN04C (40V, 130A @ 25°C, Rds(on): 2.5mOhm)
PWM Controller(s): 2x ANPEC APW7164
Filtering Capacitors

Electrolytic:
6x Teapo (1-3,000h @ 105°C, SC ),
2x Nippon Chemi-con (2-5,000h @ 105°C, KZE )
1x Rubycon (4-10,000h @ 105°C, YXF )
Polymer:
12x Teapo, 10x CS(12Kuang Jin)

Supervisor IC IN1T70312-SDG
Fan Controller 1x 2SB1424 PNP transistor
Fan Model Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier 1x PS1060L SBR (60V, 10A)
Standby PWM Controller Grenergy GR9877BU

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB