CX750 (ATXv3.1)
| Electronic Loads | Chroma 63601-5 x2 Chroma 63600-2 Chroma 63640-80-80 x10 Chroma 63610-80-20 |
| AC Sources | Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500 |
| Power Analyzers | Rohde & Schwarz HMC8015 & NPA701 |
| Oscilloscopes | Picoscope 4444, Siglent SDS2104X PLUS |
| Sound Analyzer | Bruel & Kjaer 2270 G4 |
| Microphone | Bruel & Kjaer Type 4955-A |
| Temperature Logger | Picoscope TC-08 |
| Tachometer | UNI-T UT372 |
| Multimeters | Keysight 34465A |
| EMI Analyzer | TekBox TBMR-110M-EU |
| Isolation Transformer | 4kVA |
| UPS | FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA |
| Testing Methodology | Cybenetics PSU Test Protocol |
| Voltage | 115V | 230V |
|---|---|---|
| Efficiency (>1450 Load Combinations) | 88.363% | 90.617% |
| Efficiency Graphs | ||
| Average PF (>1450 Load Combinations) | 0.994 | 0.968 |
| 12V Step | 7.00W | |
| 5V/3.3V Step | 2.50W | |
| Standby Power Consumption | 0.0497W | 0.0969W |
| ErP Lot 3/6 Ready | ✓ | |
| (EU) No 617/2013 Compliance | ✓ | |
| Average Efficiency VSB | 81.242% | 81.394% |
| Conducted Emissions EN 55032 & CISPR 32 (48W) | Passed | |
Conducted Emissions Graphs ![]() ![]() | ||
| Load range | Points | Efficiency 115V | Efficiency 230V | PF 115V | PF 230V |
|---|---|---|---|---|---|
| 0-<20 % | 185 / 183 | 83.32% | 84.78% | 0.979 | 0.876 |
| 20-<40 % | 321 / 321 | 88.89% | 90.49% | 0.994 | 0.963 |
| 40-<60 % | 321 / 323 | 89.91% | 91.93% | 0.997 | 0.982 |
| 60-<80 % | 322 / 322 | 89.34% | 91.95% | 0.997 | 0.988 |
| 80-100 % | 328 / 328 | 88.21% | 91.40% | 0.998 | 0.992 |
| 70-100 % (High-Load) | 490 / 490 | 88.51% | 91.56% | 0.997 | 0.991 |
| All (published average) | 1477 / 1477 | 88.36% | 90.62% | 0.994 | 0.968 |
The average efficiency and power factor in five ranges of load. Calculated from the 1477 (115V) and 1477 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.
Informational. Not part of the ETA or LAMBDA rating.
| Voltage | 115V | 230V |
|---|---|---|
| Noise Rating (>1450 Load Combinations) | 38.03dBA | 36.67dBA |
| Noise Graphs | ||
| Load range | Noise 115V avg (loudest) | Noise 230V avg (loudest) | Fan off 115V / 230V |
|---|---|---|---|
| 0-<20 % | 23.1 (23.1) | 23.1 (23.1) | 0% / 0% |
| 20-<40 % | 23.4 (28.0) | 23.6 (28.0) | 0% / 0% |
| 40-<60 % | 29.5 (35.6) | 28.0 (34.0) | 0% / 0% |
| 60-<80 % | 37.0 (43.4) | 35.2 (42.5) | 0% / 0% |
| 80-100 % | 43.5 (46.5) | 42.2 (44.9) | 0% / 0% |
| 70-100 % (High-Load) | 42.4 (46.5) | 41.1 (44.9) | 0% / 0% |
| All (published average) | 38.0 (46.5) | 36.7 (44.9) | 0% / 0% |
The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1477 (115V) and 1477 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 750 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 795 RPM · 23.0 dB(A) · 29.8 °C | 824 RPM · 24.0 dB(A) · 40.5 °C | +1.0 dB(A) |
| 20% | 801 RPM · 23.2 dB(A) · 30.2 °C | 825 RPM · 24.0 dB(A) · 40.8 °C | +0.8 dB(A) |
| 50% | 864 RPM · 24.6 dB(A) · 30.7 °C | 1221 RPM · 34.5 dB(A) · 42.5 °C | +9.9 dB(A) |
| 100% | 1979 RPM · 46.5 dB(A) · 30.6 °C | 2103 RPM · 48.7 dB(A) · 45.1 °C | +2.2 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 796 RPM · 23.0 dB(A) · 30.6 °C | 825 RPM · 24.0 dB(A) · 40.3 °C | +1.0 dB(A) |
| 20% | 799 RPM · 23.1 dB(A) · 29.9 °C | 827 RPM · 24.0 dB(A) · 40.8 °C | +0.9 dB(A) |
| 50% | 802 RPM · 23.2 dB(A) · 29.9 °C | 1221 RPM · 34.5 dB(A) · 42.1 °C | +11.3 dB(A) |
| 100% | 1944 RPM · 46.3 dB(A) · 30.6 °C | 2105 RPM · 48.7 dB(A) · 45.5 °C | +2.4 dB(A) |
Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.
Informational. Not part of the ETA or LAMBDA rating.
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 67.418% |
| Hold Up Time | 13.11ms |
| Power OK | 11.01ms |
| Power OK to DC Loss | 2.10ms |
| Test\Rail | +12V | 5V | 3.3V | 5VSB |
| 100ms | 11.808 | 4.945 | 3.221 | 5.019 |
| 10ms | 11.462 | 4.919 | 3.191 | 5.006 |
| 1ms | 11.362 | 4.904 | 3.175 | 4.999 |
| 0.1ms | 11.219 | 4.899 | 3.181 | 4.992 |
| Product Identification Details | |
| Brand | Corsair |
| Model | CX750 (ATXv3.1) |
| OEM/ODM | HEC |
| Serial Number | 4656 |
| Product Specifications | |
| Manufacturer | |
| Rated Voltage (Vrms) | 100-240 |
| Rated Current (Arms) | 5-10 |
| Rated Frequency (Hz) | 47-63 |
| Rated Power (W) | 750 |
| Operating Temperature (Continuous Full Load) (°C) | 0 - 40 |
| Type | ATX12V |
| Cable Design | Fixed cables |
| Warranty | 5 years |
| Cybenetics | |
| Dimensions (W x H x D) | 150 x 85 x 125mm |
| Weight | 1.85 kg (4.08 lb) |
| Cooling | 120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z) |
| Semi-Passive Operation | ✗ |
| Cybenetics Testing Information | |
| Lab ID | CR75003296 |
| Date of receipt | May 6, 2026 |
| Testing Date | May 21, 2026 |
| Report Issued Date | May 28, 2026 |
| Engineer Name | Ioannis Kalyviotis |
| Authorized By the Laboratory Technical Manager | Aristeidis Bitziopoulos |
| Signature | ![]() |
| Captive Cables | ||||
| Description | Cable Count | Connector Count (Total) | Gauge | Cable Type |
| ATX connector 24 pin (610mm) | 1 | 1 | 16-20AWG | Tinned Copper |
| 8 pin EPS12V (530mm) / 4+4 pin EPS12V (+100mm) | 1 | 1 / 1 | 18AWG | Tinned Copper |
| 6+2 pin PCIe (520mm+100mm) | 1 | 2 | 18AWG | Tinned Copper |
| 6+2 pin PCIe (640mm) | 1 | 1 | 18AWG | Tinned Copper |
| 12+2 pin PCIe (630mm) (600W) | 1 | 1 | 16-24AWG | Tinned Copper |
| SATA (400mm+100mm+100mm) | 1 | 3 | 18AWG | Tinned Copper |
| 4-pin Molex (420mm+100mm) | 1 | 2 | 18AWG | Tinned Copper |
| Modular Cables | ||||
| AC Power Cord (1400mm) - C13 coupler | 1 | 1 | 18AWG | - |
| Under Voltage Protection | ✓ |
| Over Power Protection | ✓ |
| Over Current (+12V) Protection | ✓ |
| Over Temperature Protection | ✓ |
| Short Circuit Protection | ✓ |
| Surge Protection | ✓ |
| Inrush Current Protection | ✓ |
| Fan Failure Protection | ✗ |
| General Data | |
| Manufacturer (OEM) | HEC |
| PCB Type | Double-Sided |
| Primary Side | |
| Transient Filter | 5x Y caps, 3x X caps, 2x CM chokes, 1x MOV |
| Inrush Protection | NTC Thermistor 3D-15 (3Ohm @ 25°C) |
| Bridge Rectifier(s) | 1x MCC GBU15K (800V, 15A @ 100°C) |
| APFC MOSFETs | 2x Pingwei PWE180N65MFS (650V, 13A @ 100°C, Rds(on): 0.18 Ohm) |
| APFC Boost Diode | Hestia Power H3S065A006 (650V, 6A @ 156°C) |
| Bulk Cap(s) | 1x Teapo (400V, 390uF, 2,000h @ 105°C, LG ) |
| Main Switchers | 2x Pingwei PWE180N65MFS (650V, 13A @ 100°C, Rds(on): 0.18 Ohm) |
| APFC/LLC Controller Combo | Monolithic Power Systems HR1280 |
| Topology | Primary side: APFC, Half-Bridge & LLC Resonant converter Secondary side: Synchronous Rectification & DC-DC converters |
| Secondary Side | |
| +12V MOSFETs | 4x Pingwei PWC012N04ES (40V, 132A @ 100°C, Rds(on): 1.2 mOhm) |
| SR Controller | MPS MP6924B |
| 5V & 3.3V | DC-DC Converters: 2x Potens Semiconductor PDC39F2BX (30V, 76A @ 100°C, Rds(on): 2.95mOhm) 2x CHANG JING CJAC2R5SN04C (40V, 130A @ 25°C, Rds(on): 2.5mOhm) PWM Controller(s): 2x ANPEC APW7164 |
| Filtering Capacitors | Electrolytic: |
| Supervisor IC | IN1T70312-SDG |
| Fan Controller | 1x 2SB1424 PNP transistor |
| Fan Model | Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan) |
| 5VSB Circuit | |
| Rectifier | 1x PS1060L SBR (60V, 10A) |
| Standby PWM Controller | Grenergy GR9877BU |




F.1 General Statement
Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.
The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.
The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.
Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.
F.2 Expanded Measurement Uncertainty by Measurement Type
| Measurement | Expanded Uncertainty U (k=2, norm) |
| Efficiency | ±0.43% |
| Timings | ±2.64ms |
| Power Excursions (Transient Response) | ±0.18V |
| Conducted EMI Emissions (150 kHz – 30 MHz) | ±2.35 dB |
| Noise Output | ±1.23 dB |