Customer: Micronics
HANMI MICRONICS. INC. 72, Samdo-ro 48beon-gil, Yangchon-eup,
Gimpo-si, Gyeonggi-do, Korea

Coolmax Focus II ETA Bronze 500W

Report Number: 22PS1999A
Customer ID: 75

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)0.000%84.954%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.0000.970
Standby Power Consumption0.0000W0.1572W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB0.000%78.498%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)0.00dBA26.65dBA
Noise Graphs

Section D: Information about DUT

Model NameMicronics
Serial Number
CommentsTurn on off to full κανει μεγάλο βύθισμα DC sq τα 3.3V προπορεύονται ελάχιστα των 5V OPP πήρα manual OCP 5V & 3.3V δεν έκλεισε (κοκκινισε) OCP 12V έκλεισε στα κόκκινα
Date of receiptMar 24, 2022
Testing DateMar 31, 2022
Report Issued DateMar 31, 2022
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.