Customer: SilverStone
12F No. 168 Jiankang Rd.,
Zhonghe Dist., New Taipei City 23585,Taiwan R.O.C

Strider Essential 700W 230V

Report Number: 21PS1804A
Customer ID: 51

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)0.000%84.896%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.0000.977
Standby Power Consumption0.0000W0.1947W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB0.000%73.835%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)0.00dBA35.30dBA
Noise Graphs

Section D: Information about DUT

Model NameSilverStone
Serial NumberVA700-B-230
CommentsNT230V CL1 πάρθηκε με 3Α στα 12V, CL2 πάρθηκε με 3Α στα minor
Date of receiptFeb 22, 2021
Testing DateMar 23, 2021
Report Issued DateMar 4, 2021
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.