C-Link USB Cable (800mm) / C-Link I2C Cable (800mm)
1 / 1
1 / 1
24-28 / 29AWG
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
PLATINUM
Noise Rating
A
Average Efficiency (>1450 load combinations)
89.602%
Average Noise Output (>1450 Load Combinations)
20.05dBA
Average PF (>1450 Load Combinations)
0.993
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0439W
12V Ripple (Full Load)
47.74mV
5V Ripple (Full Load)
13.97mV
3.3V Ripple (Full Load)
18.96mV
5VSB Ripple (Full Load)
18.31mV
12V Load Regulation
1.45%
5V Load Regulation
1.04%
3.3V Load Regulation
0.66%
5VSB Load Regulation
1.79%
Inrush Current
29.167A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
18.92
AC Loss to PWR_OK Hold Up Time (ms)
16.72
PWR_OK Inactive to DC Loss Delay (ms)
2.20
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
69.508%
0.030
5.057V
0.305
115.06V
2
0.087A
0.442
75.556%
0.058
5.056V
0.585
115.07V
3
0.532A
2.686
80.806%
0.268
5.047V
3.324
115.05V
4
3.001A
14.977
78.652%
0.529
4.990V
19.042
115.06V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.462A
1.995A
1.992A
1.000A
99.797
88.029%
0
0
45.85°C
0.979
12.107V
5.005V
3.309V
4.985V
113.368
38.27°C
115.10V
2
13.962A
3.002A
2.994A
1.207A
199.687
91.410%
0
0
45.84°C
0.991
12.090V
4.993V
3.305V
4.973V
218.451
38.77°C
115.10V
3
21.850A
3.508A
3.514A
1.405A
299.877
92.283%
0
0
47.40°C
0.994
12.073V
4.991V
3.299V
4.968V
324.952
39.35°C
115.10V
4
29.741A
3.996A
4.000A
1.606A
399.625
92.310%
0
0
49.11°C
0.996
12.052V
5.007V
3.296V
4.977V
432.914
40.12°C
115.10V
5
37.321A
4.975A
4.982A
1.801A
499.583
91.924%
0
0
48.15°C
0.997
12.034V
5.021V
3.310V
4.993V
543.473
40.73°C
115.09V
6
44.915A
5.983A
5.965A
2.007A
599.525
91.392%
608
17.5
41.77°C
0.997
12.017V
5.013V
3.318V
4.981V
655.991
53.67°C
115.09V
7
52.510A
7.002A
6.969A
2.211A
699.445
90.755%
788
19.6
42.18°C
0.997
12.004V
5.003V
3.314V
4.970V
770.696
51.85°C
115.08V
8
60.147A
8.019A
7.977A
2.422A
799.266
90.084%
874
21.3
42.82°C
0.996
11.985V
4.989V
3.309V
4.955V
887.245
52.64°C
115.08V
9
68.240A
8.533A
8.502A
2.424A
899.275
89.244%
960
22.3
43.99°C
0.996
11.968V
4.980V
3.304V
4.948V
1007.663
54.44°C
115.07V
10
76.102A
9.064A
9.007A
3.044A
998.926
88.064%
1116
26.2
45.51°C
0.996
11.947V
4.969V
3.298V
4.925V
1134.313
56.55°C
115.07V
11
84.602A
9.073A
9.020A
3.050A
1098.750
86.960%
1287
30.3
46.79°C
0.996
11.927V
4.962V
3.291V
4.917V
1263.513
57.98°C
115.08V
CL1
0.098A
18.028A
18.002A
0.002A
151.586
83.494%
878
21.3
44.90°C
0.988
12.074V
4.982V
3.365V
5.030V
181.553
53.64°C
115.12V
CL2
83.252A
1.003A
1.001A
1.001A
1007.857
88.429%
1156
27.0
45.83°C
0.996
11.948V
4.950V
3.256V
4.933V
1139.730
55.72°C
115.02V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.205A
0.492A
0.482A
0.196A
19.665
65.809%
0
0
0.839
12.129V
5.020V
3.313V
5.015V
29.882
115.10V
2
2.435A
0.991A
0.997A
0.396A
39.774
79.059%
0
0
0.925
12.123V
5.016V
3.312V
5.006V
50.309
115.10V
3
3.667A
1.487A
1.510A
0.601A
59.892
83.563%
0
0
0.948
12.117V
5.012V
3.312V
4.998V
71.673
115.10V
4
4.889A
1.995A
1.991A
0.801A
79.794
86.843%
0
0
0.977
12.112V
5.007V
3.310V
4.991V
91.883
115.10V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.9 mV
5.9 mV
5.9 mV
5.0 mV
Pass
20% Load
14.1 mV
5.2 mV
6.1 mV
5.5 mV
Pass
30% Load
18.8 mV
5.9 mV
7.4 mV
6.9 mV
Pass
40% Load
24.1 mV
6.2 mV
8.6 mV
7.7 mV
Pass
50% Load
22.7 mV
7.6 mV
10.6 mV
9.1 mV
Pass
60% Load
24.8 mV
7.5 mV
11.4 mV
9.7 mV
Pass
70% Load
28.3 mV
8.4 mV
12.6 mV
11.3 mV
Pass
80% Load
32.6 mV
10.4 mV
13.8 mV
13.3 mV
Pass
90% Load
38.9 mV
10.7 mV
15.9 mV
14.8 mV
Pass
100% Load
47.7 mV
14.0 mV
19.0 mV
18.3 mV
Pass
110% Load
61.1 mV
14.6 mV
21.3 mV
19.9 mV
Pass
Crossload 1
16.4 mV
8.7 mV
11.9 mV
9.4 mV
Pass
Crossload 2
45.7 mV
10.8 mV
17.8 mV
15.0 mV
Pass
The results above are not used in the certification process
Corsair HX1000i
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted