ErP Lot 6 2010: ✓
ErP Lot 6 2013: Partially
ErP Lot 3 2014: ✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
PLATINUM
Noise Rating
A-
Average Efficiency (>1450 load combinations)
89.161%
Average Noise Output (>1450 Load Combinations)
29.84dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1190W
12V Ripple (Full Load)
12.32mV
5V Ripple (Full Load)
8.35mV
3.3V Ripple (Full Load)
9.35mV
5VSB Ripple (Full Load)
10.17mV
12V Load Regulation
0.30%
5V Load Regulation
0.12%
3.3V Load Regulation
0.12%
5VSB Load Regulation
2.96%
Inrush Current
33.080A
Efficiency Rating
Noise Rating
A-
Average Efficiency (>1450 load combinations)
91.143%
Average Noise Output (>1450 Load Combinations)
29.28dBA
Average PF (>1450 Load Combinations)
0.957
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.2273W
12V Ripple (Full Load)
11.61mV
5V Ripple (Full Load)
7.64mV
3.3V Ripple (Full Load)
7.00mV
5VSB Ripple (Full Load)
8.73mV
12V Load Regulation
0.27%
5V Load Regulation
0.12%
3.3V Load Regulation
0.09%
5VSB Load Regulation
2.92%
Inrush Current
63.670A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
18.44ms
AC Loss to PWR_OK Hold Up Time
16.64ms
PWR_OK Inactive to DC Loss Delay
1.80ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
18.44
AC Loss to PWR_OK Hold Up Time (ms)
16.64
PWR_OK Inactive to DC Loss Delay (ms)
1.80
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
55.759%
0.046
5.108V
0.382
115.09V
2
0.087A
0.445
66.717%
0.078
5.107V
0.667
115.10V
3
0.532A
2.709
76.720%
0.292
5.093V
3.531
115.10V
4
3.003A
14.928
76.409%
0.492
4.971V
19.537
115.08V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
43.030%
0.018
5.107V
0.495
230.27V
2
0.087A
0.446
56.815%
0.028
5.107V
0.785
230.27V
3
0.532A
2.709
73.196%
0.123
5.093V
3.701
230.27V
4
3.001A
15.025
77.146%
0.353
5.006V
19.476
230.26V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.407A
1.986A
1.989A
0.985A
74.783
84.566%
1339
33.3
37.52°C
0.966
12.074V
5.028V
3.316V
5.067V
88.431
39.43°C
115.11V
2
9.856A
2.981A
2.984A
1.185A
149.782
89.023%
1339
33.3
38.20°C
0.981
12.064V
5.030V
3.316V
5.055V
168.251
39.88°C
115.11V
3
15.662A
3.483A
3.494A
1.386A
224.890
90.372%
1364
33.5
38.81°C
0.989
12.055V
5.028V
3.315V
5.043V
248.848
40.79°C
115.11V
4
21.454A
3.977A
3.980A
1.590A
299.743
90.770%
1384
33.8
39.58°C
0.992
12.052V
5.026V
3.314V
5.032V
330.223
41.87°C
115.11V
5
26.911A
4.973A
4.976A
1.791A
374.723
90.617%
1415
35.2
40.00°C
0.993
12.049V
5.026V
3.314V
5.019V
413.525
42.87°C
115.11V
6
32.362A
5.965A
5.972A
1.996A
449.637
90.239%
1448
37.6
41.41°C
0.994
12.047V
5.028V
3.314V
5.004V
498.276
44.55°C
115.10V
7
37.813A
6.968A
6.969A
2.200A
524.645
89.742%
1476
36.9
41.98°C
0.995
12.047V
5.028V
3.314V
4.992V
584.618
45.74°C
115.10V
8
43.265A
7.955A
7.963A
2.409A
599.558
89.013%
1530
37.1
42.69°C
0.995
12.046V
5.028V
3.315V
4.978V
673.564
46.98°C
115.10V
9
49.156A
8.463A
8.480A
2.409A
674.644
88.400%
1583
38.1
43.59°C
0.995
12.044V
5.026V
3.313V
4.973V
763.171
48.51°C
115.10V
10
54.786A
8.962A
8.965A
3.031A
749.496
87.559%
1631
39.9
44.87°C
0.996
12.043V
5.024V
3.312V
4.946V
855.994
50.52°C
115.10V
11
61.015A
8.968A
8.972A
3.032A
824.382
86.870%
1667
40.1
46.45°C
0.996
12.041V
5.021V
3.309V
4.942V
948.987
52.60°C
115.10V
CL1
0.099A
14.025A
14.005A
0.004A
119.170
82.812%
1544
37.4
43.16°C
0.977
12.071V
5.069V
3.346V
5.081V
143.905
45.77°C
115.12V
CL2
62.452A
1.004A
1.003A
1.002A
765.148
88.041%
1596
38.2
44.76°C
0.996
12.038V
4.995V
3.290V
5.027V
869.081
49.69°C
115.11V
The results above are not used in the certification process
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.207A
0.493A
0.481A
0.195A
19.648
71.176%
0
0
0.846
12.082V
5.025V
3.314V
5.097V
27.605
115.12V
2
2.443A
0.990A
0.994A
0.391A
39.770
80.573%
0
0
0.929
12.079V
5.026V
3.315V
5.089V
49.359
115.12V
3
3.678A
1.487A
1.506A
5.080A
59.887
85.302%
0
0
0.965
12.076V
5.028V
3.315V
5.080V
70.206
115.11V
4
4.905A
1.984A
1.989A
0.786A
79.772
86.991%
0
0
0.966
12.073V
5.028V
3.315V
5.071V
91.701
115.11V
The results above are not used in the certification process
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
4.3 mV
4.1 mV
5.4 mV
4.5 mV
Pass
20% Load
5.6 mV
4.2 mV
6.0 mV
4.9 mV
Pass
30% Load
7.0 mV
4.6 mV
6.0 mV
5.2 mV
Pass
40% Load
7.6 mV
4.7 mV
6.5 mV
5.4 mV
Pass
50% Load
8.6 mV
5.2 mV
6.6 mV
5.8 mV
Pass
60% Load
9.3 mV
5.8 mV
7.2 mV
5.9 mV
Pass
70% Load
9.8 mV
7.0 mV
6.7 mV
6.4 mV
Pass
80% Load
11.0 mV
6.9 mV
7.5 mV
7.9 mV
Pass
90% Load
11.5 mV
7.9 mV
8.0 mV
9.3 mV
Pass
100% Load
12.3 mV
8.4 mV
9.4 mV
10.2 mV
Pass
107% Load
12.8 mV
9.0 mV
9.8 mV
10.2 mV
Pass
Crossload 1
6.8 mV
5.8 mV
8.3 mV
11.6 mV
Pass
Crossload 2
11.7 mV
8.4 mV
8.8 mV
8.2 mV
Pass
The results above are not used in the certification process
The results above are not used in the certification process
Super Flower Leadex II 750W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted