This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.102A
0.514
76.602%
0.065
5.055V
0.671
115.04V
2
0.252A
1.274
80.025%
0.143
5.052V
1.592
115.04V
3
1.002A
5.049
81.778%
0.336
5.037V
6.174
115.06V
4
3.002A
14.989
80.960%
0.445
4.993V
18.514
115.03V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.411A
1.985A
1.989A
0.996A
74.811
84.958%
0
0
41.68°C
0.943
12.061V
5.043V
3.315V
5.025V
88.056
37.94°C
115.09V
2
9.877A
2.971A
2.986A
1.195A
149.775
89.254%
0
0
43.16°C
0.987
12.040V
5.039V
3.311V
5.019V
167.807
38.70°C
115.09V
3
15.710A
3.477A
3.503A
1.396A
224.909
90.474%
0
0
43.61°C
0.991
12.019V
5.035V
3.308V
5.012V
248.589
39.86°C
115.09V
4
21.557A
3.975A
3.990A
1.596A
299.797
90.750%
0
0
44.73°C
0.994
11.997V
5.032V
3.305V
5.006V
330.356
40.43°C
115.08V
5
27.079A
4.972A
4.996A
1.799A
374.762
90.524%
0
0
45.35°C
0.996
11.975V
5.029V
3.301V
5.000V
413.992
41.28°C
115.08V
6
32.617A
5.972A
6.002A
2.001A
449.697
90.012%
612
17.5
42.06°C
0.996
11.954V
5.024V
3.298V
4.995V
499.599
65.41°C
115.08V
7
38.171A
6.977A
7.011A
2.202A
524.717
89.464%
716
18.8
42.09°C
0.996
11.936V
5.020V
3.294V
4.991V
586.511
65.26°C
115.08V
8
43.756A
7.975A
8.020A
2.405A
599.658
88.790%
821
20.1
42.95°C
0.997
11.913V
5.017V
3.291V
4.985V
675.369
66.44°C
115.08V
9
49.795A
8.479A
8.540A
2.406A
674.686
88.067%
906
21.4
43.83°C
0.997
11.891V
5.013V
3.288V
4.983V
766.104
68.53°C
115.08V
10
55.599A
8.989A
9.039A
3.016A
749.551
87.196%
1075
24.8
45.21°C
0.997
11.868V
5.009V
3.285V
4.968V
859.618
71.62°C
115.08V
11
62.033A
8.994A
9.046A
3.021A
824.440
86.286%
1160
27.0
46.55°C
0.997
11.844V
5.007V
3.282V
4.965V
955.479
74.79°C
115.08V
CL1
0.098A
18.027A
18.002A
0.004A
150.937
81.569%
767
19.2
44.85°C
0.988
12.018V
5.018V
3.293V
5.077V
185.043
61.99°C
115.11V
CL2
62.448A
1.003A
1.003A
1.002A
754.610
87.769%
1108
25.8
45.57°C
0.997
11.870V
5.020V
3.296V
5.001V
859.771
68.11°C
115.08V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.209A
0.491A
0.478A
0.196A
19.658
67.092%
0
0
0.839
12.082V
5.047V
3.318V
5.041V
29.300
115.09V
2
2.447A
0.990A
0.993A
0.397A
39.837
79.572%
0
0
0.937
12.076V
5.045V
3.316V
5.036V
50.064
115.09V
3
3.684A
1.476A
1.505A
0.596A
59.893
83.128%
0
0
0.940
12.068V
5.043V
3.316V
5.032V
72.049
115.09V
4
4.908A
1.985A
1.990A
0.796A
79.806
85.455%
0
0
0.952
12.061V
5.043V
3.315V
5.029V
93.390
115.09V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.6 mV
13.5 mV
6.9 mV
6.4 mV
Pass
20% Load
7.9 mV
13.4 mV
7.9 mV
6.1 mV
Pass
30% Load
9.4 mV
14.8 mV
9.8 mV
7.5 mV
Pass
40% Load
10.6 mV
14.5 mV
11.1 mV
6.8 mV
Pass
50% Load
11.7 mV
15.0 mV
11.8 mV
7.8 mV
Pass
60% Load
12.8 mV
15.4 mV
14.3 mV
8.1 mV
Pass
70% Load
14.6 mV
16.3 mV
17.0 mV
8.6 mV
Pass
80% Load
16.2 mV
17.1 mV
15.4 mV
9.7 mV
Pass
90% Load
17.6 mV
17.8 mV
16.3 mV
10.8 mV
Pass
100% Load
20.2 mV
19.2 mV
17.8 mV
12.9 mV
Pass
107% Load
22.5 mV
20.7 mV
19.6 mV
14.4 mV
Pass
Crossload 1
10.9 mV
16.0 mV
10.9 mV
8.0 mV
Pass
Crossload 2
19.7 mV
19.4 mV
17.2 mV
13.2 mV
Pass
The results above are not used in the certification process
Corsair RM750i
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case