Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Efficiency Rating
SILVER
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
87.543%
Average Noise Output (>1450 Load Combinations)
36.74dBA
Average PF (>1450 Load Combinations)
0.939
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1829W
12V Ripple (Full Load)
42.51mV
5V Ripple (Full Load)
24.90mV
3.3V Ripple (Full Load)
27.68mV
5VSB Ripple (Full Load)
28.56mV
12V Load Regulation
1.27%
5V Load Regulation
2.91%
3.3V Load Regulation
2.83%
5VSB Load Regulation
4.10%
Inrush Current
0.000A
Hold-Up Time & Power Ok Signal
22.00ms
AC Loss to PWR_OK Hold Up Time
62.00ms
PWR_OK Inactive to DC Loss Delay
-40.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
22
AC Loss to PWR_OK Hold Up Time (ms)
62
PWR_OK Inactive to DC Loss Delay (ms)
-40
Vampire Power
Tables 230V
Graphs 230V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
47.368%
0.010
5.182V
0.494
230.33V
2
0.090A
0.467
59.566%
0.015
5.181V
0.784
230.33V
3
0.550A
2.840
77.048%
0.069
5.163V
3.686
230.32V
4
1.000A
5.147
78.797%
0.119
5.146V
6.532
230.32V
5
1.500A
7.690
79.377%
0.167
5.126V
9.688
230.32V
6
3.000A
15.199
78.588%
0.275
5.066V
19.340
230.32V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.572A
2.008A
1.963A
0.975A
64.764
85.598%
0
<6.0
40.43°C
0.719
12.087V
4.980V
3.355V
5.131V
75.661
34.03°C
230.31V
2
8.166A
3.021A
2.958A
1.174A
129.294
88.239%
0
<6.0
41.57°C
0.868
12.050V
4.964V
3.345V
5.113V
146.527
34.73°C
230.31V
3
13.143A
3.536A
3.445A
1.374A
194.414
89.345%
0
<6.0
42.45°C
0.923
12.054V
4.948V
3.335V
5.097V
217.600
35.48°C
230.31V
4
18.151A
4.051A
3.968A
1.575A
259.633
89.759%
1216
26.8
35.69°C
0.947
12.035V
4.935V
3.325V
5.080V
289.257
43.58°C
230.31V
5
22.835A
5.084A
4.977A
1.779A
324.931
89.510%
1463
32.7
36.11°C
0.961
12.018V
4.918V
3.314V
5.061V
363.011
44.29°C
230.31V
6
27.472A
6.121A
5.991A
1.983A
389.458
89.073%
1784
38.3
36.52°C
0.968
12.000V
4.901V
3.304V
5.043V
437.236
45.12°C
230.31V
7
32.185A
7.168A
7.014A
2.190A
454.779
88.417%
1315
28.9
37.34°C
0.973
11.983V
4.884V
3.293V
5.023V
514.358
46.32°C
230.32V
8
36.908A
8.220A
8.043A
2.399A
520.084
87.707%
2279
43.4
37.91°C
0.977
11.967V
4.867V
3.282V
5.003V
592.981
47.45°C
230.34V
9
42.051A
8.757A
8.555A
2.404A
585.017
86.965%
2383
44.4
38.88°C
0.980
11.950V
4.854V
3.273V
4.992V
672.706
48.95°C
230.32V
10
46.937A
9.297A
9.099A
3.028A
649.850
86.039%
2381
44.4
39.75°C
0.982
11.934V
4.841V
3.263V
4.956V
755.300
50.39°C
230.32V
11
52.435A
9.313A
9.120A
3.034A
714.671
85.053%
2385
44.4
40.45°C
0.983
11.919V
4.833V
3.255V
4.945V
840.266
51.93°C
230.33V
CL1
0.143A
14.002A
14.000A
0.000A
116.395
80.091%
1853
38.3
36.24°C
0.868
12.060V
4.876V
3.314V
5.132V
145.329
44.48°C
230.39V
CL2
54.008A
1.001A
0.998A
1.000A
658.380
86.769%
2380
44.4
39.56°C
0.982
11.945V
4.911V
3.290V
5.055V
758.769
50.62°C
230.32V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.193A
0.499A
0.475A
0.193A
19.492
77.276%
0
<6.0
0.375
12.072V
4.998V
3.365V
5.171V
25.224
230.31V
2
2.452A
1.001A
0.978A
0.388A
39.915
83.536%
0
<6.0
0.575
12.084V
4.991V
3.361V
5.160V
47.782
230.30V
3
3.637A
1.505A
1.457A
0.583A
59.361
85.820%
0
<6.0
0.694
12.089V
4.984V
3.357V
5.149V
69.169
230.30V
4
4.904A
2.008A
1.967A
0.779A
79.789
86.674%
0
<6.0
0.770
12.071V
4.978V
3.353V
5.137V
92.056
230.30V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
59.2 mV
19.8 mV
14.3 mV
13.9 mV
Pass
20% Load
72.9 mV
20.2 mV
15.2 mV
15.0 mV
Pass
30% Load
29.0 mV
16.8 mV
16.1 mV
19.2 mV
Pass
40% Load
27.9 mV
18.2 mV
15.8 mV
17.3 mV
Pass
50% Load
26.5 mV
18.3 mV
16.3 mV
17.6 mV
Pass
60% Load
25.4 mV
18.8 mV
18.6 mV
19.5 mV
Pass
70% Load
24.9 mV
19.7 mV
20.0 mV
19.9 mV
Pass
80% Load
26.6 mV
20.9 mV
23.6 mV
21.9 mV
Pass
90% Load
26.5 mV
22.2 mV
23.9 mV
24.4 mV
Pass
100% Load
42.5 mV
24.9 mV
27.7 mV
28.6 mV
Pass
110% Load
43.9 mV
24.6 mV
25.9 mV
29.1 mV
Pass
Crossload 1
75.2 mV
29.3 mV
28.6 mV
16.4 mV
Pass
Crossload 2
41.5 mV
21.3 mV
16.5 mV
24.1 mV
Pass
The results above are not used in the certification process
Cooler Master MWE 650 (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted