This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.102A
0.518
74.106%
0.075
5.110V
0.699
115.07V
2
0.252A
1.284
78.725%
0.162
5.104V
1.631
115.07V
3
1.002A
5.081
80.281%
0.377
5.071V
6.329
115.07V
4
3.002A
14.979
78.891%
0.495
4.990V
18.987
115.07V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
8.020A
1.983A
1.985A
0.986A
119.805
87.769%
769
27.4
38.52°C
0.982
12.246V
5.049V
3.323V
5.055V
136.500
43.85°C
115.10V
2
17.064A
2.969A
2.978A
1.190A
239.650
90.853%
1007
33.6
39.35°C
0.984
12.235V
5.049V
3.321V
5.036V
263.777
44.89°C
115.09V
3
26.481A
3.466A
3.494A
1.395A
359.845
91.406%
1349
42.1
39.98°C
0.989
12.226V
5.048V
3.319V
5.015V
393.679
45.86°C
115.08V
4
35.898A
3.964A
3.976A
1.600A
479.643
91.147%
1808
51.2
40.88°C
0.993
12.214V
5.047V
3.317V
4.994V
526.233
46.61°C
115.09V
5
44.991A
4.959A
4.974A
1.806A
599.565
90.641%
2061
52.4
41.67°C
0.995
12.204V
5.046V
3.315V
4.974V
661.470
48.01°C
115.10V
6
54.110A
5.943A
5.975A
2.015A
719.468
90.181%
2061
52.4
42.55°C
0.996
12.192V
5.046V
3.312V
4.953V
797.804
49.46°C
115.10V
7
63.229A
6.938A
6.978A
2.229A
839.365
89.649%
2061
52.4
43.70°C
0.997
12.182V
5.047V
3.310V
4.933V
936.282
51.95°C
115.11V
8
72.369A
7.925A
7.977A
2.441A
959.236
88.859%
2061
52.4
44.37°C
0.997
12.172V
5.047V
3.307V
4.909V
1079.504
53.82°C
115.12V
9
81.963A
8.433A
8.501A
2.448A
1079.285
88.017%
2061
52.4
45.23°C
0.998
12.160V
5.043V
3.305V
4.898V
1226.225
55.72°C
115.12V
10
91.313A
8.928A
8.991A
3.084A
1199.062
87.030%
2061
52.4
45.52°C
0.998
12.149V
5.043V
3.303V
4.857V
1377.763
56.76°C
115.12V
11
101.360A
8.937A
8.999A
3.091A
1319.107
86.320%
2061
52.4
45.58°C
0.998
12.129V
5.038V
3.300V
4.850V
1528.165
58.01°C
115.11V
CL1
0.099A
15.019A
15.006A
0.005A
127.176
84.037%
1349
42.1
39.53°C
0.991
12.256V
5.074V
3.314V
5.081V
151.333
44.95°C
115.11V
CL2
99.941A
1.003A
1.002A
1.002A
1225.824
87.099%
2061
52.4
43.49°C
0.998
12.132V
5.030V
3.312V
4.965V
1407.386
54.91°C
115.12V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.190A
0.492A
0.479A
0.197A
19.666
65.696%
732
24.3
0.852
12.252V
5.052V
3.329V
5.099V
29.935
115.10V
2
2.408A
0.985A
0.989A
0.391A
39.751
77.143%
732
24.3
0.929
12.250V
5.050V
3.326V
5.089V
51.529
115.10V
3
3.625A
1.478A
1.501A
0.591A
59.868
82.050%
732
24.3
0.954
12.251V
5.049V
3.324V
5.078V
72.965
115.10V
4
4.835A
1.982A
1.983A
0.785A
79.802
85.147%
750
25.1
0.975
12.249V
5.050V
3.324V
5.068V
93.723
115.10V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.2 mV
4.4 mV
6.0 mV
6.8 mV
Pass
20% Load
11.1 mV
4.6 mV
6.6 mV
9.2 mV
Pass
30% Load
10.5 mV
5.0 mV
7.0 mV
9.7 mV
Pass
40% Load
9.4 mV
4.9 mV
7.8 mV
11.5 mV
Pass
50% Load
9.8 mV
4.9 mV
7.9 mV
14.0 mV
Pass
60% Load
10.6 mV
5.7 mV
8.3 mV
16.3 mV
Pass
70% Load
11.8 mV
5.7 mV
9.5 mV
18.7 mV
Pass
80% Load
13.0 mV
8.1 mV
11.2 mV
21.7 mV
Pass
90% Load
14.0 mV
8.3 mV
11.8 mV
24.4 mV
Pass
100% Load
16.1 mV
10.5 mV
13.8 mV
28.5 mV
Pass
110% Load
31.0 mV
17.2 mV
14.3 mV
40.1 mV
Pass
Crossload 1
9.9 mV
5.9 mV
8.2 mV
7.7 mV
Pass
Crossload 2
15.6 mV
7.4 mV
12.7 mV
25.8 mV
Pass
The results above are not used in the certification process
SeaSonic Prime Gold 1200W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted