Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
SILVER
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
85.601%
Average Noise Output (>1450 Load Combinations)
30.07dBA
Average PF (>1450 Load Combinations)
0.974
Efficiency With 10W (≤500W) or 2% (>500W) Load
68.580%
Standby Power Consumption
0.0756W
12V Ripple (Full Load)
48.99mV
5V Ripple (Full Load)
24.23mV
3.3V Ripple (Full Load)
19.35mV
5VSB Ripple (Full Load)
39.17mV
12V Load Regulation
1.07%
5V Load Regulation
1.96%
3.3V Load Regulation
2.26%
5VSB Load Regulation
2.79%
Inrush Current
62.537A
Efficiency Rating
Noise Rating
A-
Average Efficiency (>1450 load combinations)
87.864%
Average Noise Output (>1450 Load Combinations)
29.96dBA
Average PF (>1450 Load Combinations)
0.896
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1812W
12V Ripple (Full Load)
50.85mV
5V Ripple (Full Load)
23.53mV
3.3V Ripple (Full Load)
18.94mV
5VSB Ripple (Full Load)
37.88mV
12V Load Regulation
1.09%
5V Load Regulation
1.94%
3.3V Load Regulation
2.26%
5VSB Load Regulation
2.79%
Inrush Current
71.267A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
17.20ms
AC Loss to PWR_OK Hold Up Time
15.80ms
PWR_OK Inactive to DC Loss Delay
1.40ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.2
AC Loss to PWR_OK Hold Up Time (ms)
15.8
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
60.622%
0.025
5.178V
0.386
115.13V
2
0.090A
0.467
69.806%
0.044
5.177V
0.669
115.13V
3
0.550A
2.842
78.835%
0.207
5.166V
3.605
115.13V
4
1.000A
5.156
79.543%
0.310
5.155V
6.482
115.12V
5
1.500A
7.715
79.643%
0.376
5.142V
9.687
115.13V
6
3.000A
15.314
77.579%
0.455
5.105V
19.740
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
47.177%
0.010
5.178V
0.496
230.29V
2
0.090A
0.467
59.566%
0.015
5.177V
0.784
230.28V
3
0.550A
2.842
77.186%
0.070
5.166V
3.682
230.29V
4
1.000A
5.156
79.068%
0.120
5.155V
6.521
230.29V
5
1.500A
7.715
79.799%
0.169
5.142V
9.668
230.29V
6
3.000A
15.314
79.401%
0.277
5.105V
19.287
230.29V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.319A
1.999A
1.966A
0.972A
49.779
82.806%
0
<6.0
40.22°C
0.913
12.149V
5.006V
3.356V
5.144V
60.115
34.60°C
115.13V
2
5.688A
3.005A
2.956A
1.169A
99.854
85.826%
0
<6.0
41.17°C
0.964
12.122V
4.995V
3.348V
5.131V
116.345
34.88°C
115.13V
3
9.393A
3.513A
3.444A
1.367A
149.764
87.212%
1044
24.2
35.47°C
0.968
12.110V
4.985V
3.340V
5.120V
171.725
42.51°C
115.13V
4
13.107A
4.020A
3.962A
1.566A
199.744
87.746%
1121
26.2
35.80°C
0.972
12.096V
4.975V
3.332V
5.109V
227.638
43.70°C
115.13V
5
16.500A
5.040A
4.965A
1.766A
249.881
87.604%
1251
29.1
36.05°C
0.977
12.083V
4.963V
3.323V
5.096V
285.238
44.55°C
115.13V
6
19.897A
6.058A
5.973A
1.968A
299.962
87.162%
1460
33.0
36.77°C
0.981
12.070V
4.952V
3.315V
5.084V
344.142
45.60°C
115.13V
7
23.302A
7.085A
6.985A
2.170A
350.078
86.543%
1487
33.1
37.36°C
0.984
12.058V
4.941V
3.306V
5.071V
404.515
46.52°C
115.12V
8
26.711A
8.116A
8.005A
2.374A
400.177
85.786%
1486
33.1
37.73°C
0.986
12.046V
4.930V
3.298V
5.057V
466.485
47.40°C
115.13V
9
30.524A
8.636A
8.508A
2.377A
449.881
84.931%
1488
33.1
38.53°C
0.988
12.035V
4.923V
3.292V
5.049V
529.701
48.80°C
115.12V
10
34.115A
9.160A
9.044A
2.986A
499.885
83.626%
1489
33.1
39.31°C
0.989
12.023V
4.914V
3.284V
5.026V
597.760
50.30°C
115.12V
11
38.310A
9.170A
9.057A
2.990A
549.897
81.932%
1489
33.1
40.30°C
0.989
12.012V
4.909V
3.279V
5.018V
671.163
51.75°C
115.12V
CL1
0.143A
14.005A
13.999A
0.000A
117.225
80.682%
1484
33.1
36.04°C
0.973
12.110V
4.931V
3.317V
5.136V
145.292
44.24°C
115.13V
CL2
41.594A
1.004A
1.000A
1.000A
513.715
84.298%
1490
33.1
39.89°C
0.989
12.029V
4.963V
3.309V
5.089V
609.402
50.91°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.320A
1.998A
1.966A
0.972A
49.785
84.197%
0
<6.0
39.94°C
0.600
12.150V
5.005V
3.356V
5.144V
59.129
34.11°C
230.29V
2
5.690A
3.004A
2.956A
1.170A
99.865
87.397%
0
<6.0
40.97°C
0.782
12.120V
4.994V
3.348V
5.131V
114.266
34.55°C
230.29V
3
9.397A
3.513A
3.442A
1.368A
149.775
88.999%
1021
24.1
35.06°C
0.852
12.107V
4.984V
3.339V
5.120V
168.288
42.00°C
230.29V
4
13.109A
4.023A
3.964A
1.566A
199.742
89.634%
1090
24.8
35.51°C
0.897
12.093V
4.974V
3.331V
5.109V
222.841
42.81°C
230.29V
5
16.505A
5.040A
4.967A
1.766A
249.872
89.662%
1246
28.5
36.25°C
0.921
12.079V
4.962V
3.322V
5.096V
278.681
43.89°C
230.29V
6
19.901A
6.062A
5.974A
1.968A
299.953
89.442%
1427
32.4
36.84°C
0.935
12.067V
4.951V
3.313V
5.083V
335.360
44.86°C
230.29V
7
23.308A
7.090A
6.990A
2.171A
350.074
89.040%
1489
33.1
37.03°C
0.945
12.054V
4.939V
3.304V
5.070V
393.163
45.60°C
230.28V
8
26.720A
8.119A
8.010A
2.374A
400.178
88.539%
1489
33.1
37.87°C
0.953
12.042V
4.928V
3.296V
5.056V
451.979
47.16°C
230.29V
9
30.538A
8.640A
8.514A
2.378A
449.887
88.031%
1494
33.2
38.12°C
0.957
12.030V
4.920V
3.289V
5.048V
511.055
48.20°C
230.29V
10
34.131A
9.166A
9.053A
2.987A
499.886
87.331%
1495
33.2
39.90°C
0.959
12.017V
4.912V
3.281V
5.024V
572.405
50.63°C
230.29V
11
38.326A
9.175A
9.064A
2.992A
549.904
86.459%
1490
33.1
40.46°C
0.964
12.007V
4.907V
3.276V
5.016V
636.027
51.91°C
230.29V
CL1
0.145A
14.004A
14.000A
0.000A
117.191
82.358%
1482
33.1
36.15°C
0.827
12.107V
4.929V
3.315V
5.135V
142.295
43.88°C
230.30V
CL2
41.595A
1.003A
1.001A
1.000A
513.516
87.965%
1494
33.2
39.31°C
0.960
12.024V
4.962V
3.308V
5.089V
583.772
50.37°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.500A
0.475A
0.194A
19.672
76.637%
0
<6.0
0.737
12.135V
5.017V
3.364V
5.170V
25.669
115.13V
2
2.451A
0.998A
0.982A
0.388A
40.067
82.408%
0
<6.0
0.877
12.143V
5.012V
3.360V
5.162V
48.620
115.13V
3
3.633A
1.497A
1.460A
0.582A
59.548
84.344%
0
<6.0
0.927
12.153V
5.007V
3.357V
5.154V
70.601
115.13V
4
4.893A
2.000A
1.969A
0.777A
79.953
85.365%
0
<6.0
0.950
12.129V
5.003V
3.353V
5.146V
93.660
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.201A
0.500A
0.476A
0.194A
19.688
77.787%
0
<6.0
0.356
12.135V
5.017V
3.364V
5.170V
25.310
230.30V
2
2.453A
0.997A
0.982A
0.388A
40.081
83.519%
0
<6.0
0.536
12.141V
5.012V
3.360V
5.162V
47.990
230.29V
3
3.634A
1.497A
1.460A
0.582A
59.552
85.929%
0
<6.0
0.647
12.151V
5.007V
3.356V
5.154V
69.304
230.29V
4
4.895A
2.001A
1.968A
0.778A
79.965
86.801%
0
<6.0
0.724
12.126V
5.002V
3.352V
5.145V
92.125
230.29V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
88.0 mV
20.8 mV
12.2 mV
19.3 mV
Pass
20% Load
88.9 mV
21.0 mV
13.3 mV
18.4 mV
Pass
30% Load
35.1 mV
19.6 mV
12.5 mV
20.6 mV
Pass
40% Load
32.5 mV
18.9 mV
12.6 mV
24.8 mV
Pass
50% Load
29.9 mV
18.3 mV
13.3 mV
27.4 mV
Pass
60% Load
29.7 mV
19.4 mV
15.6 mV
30.7 mV
Pass
70% Load
26.5 mV
18.5 mV
13.2 mV
27.1 mV
Pass
80% Load
34.2 mV
21.2 mV
18.4 mV
33.7 mV
Pass
90% Load
33.5 mV
21.3 mV
17.5 mV
33.9 mV
Pass
100% Load
49.0 mV
24.2 mV
19.4 mV
39.2 mV
Pass
110% Load
49.5 mV
24.8 mV
18.6 mV
39.3 mV
Pass
Crossload 1
43.2 mV
26.5 mV
20.6 mV
20.5 mV
Pass
Crossload 2
46.6 mV
22.5 mV
14.4 mV
35.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
89.1 mV
20.3 mV
11.9 mV
18.8 mV
Pass
20% Load
87.5 mV
20.4 mV
12.4 mV
18.0 mV
Pass
30% Load
34.7 mV
18.1 mV
11.9 mV
17.8 mV
Pass
40% Load
34.6 mV
18.7 mV
12.6 mV
22.0 mV
Pass
50% Load
32.6 mV
20.2 mV
12.7 mV
24.2 mV
Pass
60% Load
33.0 mV
18.9 mV
14.6 mV
26.4 mV
Pass
70% Load
33.6 mV
20.0 mV
15.5 mV
30.6 mV
Pass
80% Load
37.2 mV
20.2 mV
17.2 mV
33.0 mV
Pass
90% Load
33.6 mV
21.3 mV
17.2 mV
34.6 mV
Pass
100% Load
50.9 mV
23.5 mV
18.9 mV
37.9 mV
Pass
110% Load
50.6 mV
22.5 mV
17.9 mV
36.9 mV
Pass
Crossload 1
44.4 mV
27.2 mV
19.3 mV
18.5 mV
Pass
Crossload 2
50.9 mV
21.7 mV
15.5 mV
35.6 mV
Pass
The results above are not used in the certification process
Cooler Master MWE Bronze 500
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted