Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
SILVER
Noise Rating
A-
Average Efficiency (>1450 load combinations)
85.897%
Average Noise Output (>1450 Load Combinations)
25.27dBA
Average PF (>1450 Load Combinations)
0.976
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.319%
Standby Power Consumption
0.0753W
12V Ripple (Full Load)
42.75mV
5V Ripple (Full Load)
29.43mV
3.3V Ripple (Full Load)
32.65mV
5VSB Ripple (Full Load)
30.26mV
12V Load Regulation
1.40%
5V Load Regulation
2.09%
3.3V Load Regulation
2.29%
5VSB Load Regulation
2.98%
Inrush Current
34.764A
Efficiency Rating
Noise Rating
A
Average Efficiency (>1450 load combinations)
88.179%
Average Noise Output (>1450 Load Combinations)
24.66dBA
Average PF (>1450 Load Combinations)
0.904
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1873W
12V Ripple (Full Load)
42.41mV
5V Ripple (Full Load)
28.28mV
3.3V Ripple (Full Load)
31.74mV
5VSB Ripple (Full Load)
30.07mV
12V Load Regulation
1.44%
5V Load Regulation
2.07%
3.3V Load Regulation
2.23%
5VSB Load Regulation
2.89%
Inrush Current
67.384A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
20.90ms
AC Loss to PWR_OK Hold Up Time
19.30ms
PWR_OK Inactive to DC Loss Delay
1.60ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20.9
AC Loss to PWR_OK Hold Up Time (ms)
19.3
PWR_OK Inactive to DC Loss Delay (ms)
1.6
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
59.744%
0.224
5.135V
0.390
115.12V
2
0.090A
0.466
69.037%
0.043
5.170V
0.675
115.12V
3
0.550A
2.838
78.355%
0.203
5.159V
3.622
115.12V
4
1.000A
5.150
79.024%
0.305
5.148V
6.517
115.12V
5
1.500A
7.706
79.166%
0.373
5.136V
9.734
115.12V
6
3.000A
15.296
77.120%
0.464
5.099V
19.834
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
46.230%
0.010
5.172V
0.504
230.29V
2
0.090A
0.466
58.838%
0.015
5.171V
0.792
230.29V
3
0.550A
2.839
76.544%
0.070
5.160V
3.709
230.29V
4
1.000A
5.150
78.422%
0.119
5.149V
6.567
230.29V
5
1.500A
7.707
79.095%
0.168
5.137V
9.744
230.29V
6
3.000A
15.299
78.804%
0.277
5.100V
19.414
230.29V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.720A
1.998A
1.960A
0.974A
54.538
83.870%
0
<6.0
40.73°C
0.915
12.108V
5.010V
3.363V
5.137V
65.027
35.29°C
115.12V
2
6.510A
3.003A
2.949A
1.171A
109.433
84.407%
929
20.6
35.44°C
0.967
12.064V
4.997V
3.354V
5.124V
129.649
41.40°C
115.12V
3
10.697A
3.509A
3.437A
1.370A
164.925
87.752%
861
17.6
36.01°C
0.967
12.052V
4.988V
3.346V
5.111V
187.944
42.36°C
115.12V
4
14.849A
4.019A
3.953A
1.569A
219.739
88.378%
970
21.7
36.59°C
0.974
12.023V
4.979V
3.339V
5.098V
248.636
43.41°C
115.12V
5
18.665A
5.036A
4.954A
1.770A
274.645
88.321%
1040
24.2
37.26°C
0.981
12.008V
4.967V
3.331V
5.085V
310.963
44.36°C
115.12V
6
22.490A
6.057A
5.960A
1.972A
329.558
87.954%
1241
28.9
38.10°C
0.985
11.994V
4.955V
3.322V
5.071V
374.694
45.98°C
115.12V
7
26.358A
7.083A
6.969A
2.176A
384.879
87.428%
1351
31.6
38.53°C
0.987
11.980V
4.943V
3.314V
5.057V
440.222
46.97°C
115.12V
8
30.234A
8.114A
7.988A
2.380A
440.194
86.630%
1474
33.1
39.03°C
0.988
11.966V
4.931V
3.305V
5.043V
508.133
47.84°C
115.12V
9
34.486A
8.636A
8.489A
2.385A
494.721
85.890%
1477
33.1
39.41°C
0.990
11.953V
4.922V
3.298V
5.034V
575.991
48.91°C
115.12V
10
38.551A
9.164A
9.027A
2.995A
549.939
84.885%
1480
33.1
39.86°C
0.991
11.938V
4.912V
3.290V
5.010V
647.864
49.82°C
115.13V
11
43.224A
9.175A
9.040A
3.000A
605.162
83.724%
1482
33.1
40.31°C
0.991
11.925V
4.906V
3.285V
5.002V
722.810
51.81°C
115.14V
CL1
0.151A
14.004A
14.001A
0.000A
117.525
78.741%
1414
32.2
37.25°C
0.963
12.049V
4.939V
3.324V
5.124V
149.256
44.01°C
115.14V
CL2
45.851A
1.003A
1.000A
1.000A
561.012
85.608%
1480
33.1
39.44°C
0.992
11.944V
4.961V
3.316V
5.077V
655.327
49.54°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.721A
1.998A
1.961A
0.974A
54.551
85.267%
0
0
40.47°C
0.609
12.108V
5.009V
3.363V
5.137V
63.977
34.85°C
230.32V
2
6.510A
3.002A
2.951A
1.171A
109.424
85.967%
896
20.9
35.76°C
0.796
12.062V
4.998V
3.354V
5.123V
127.286
41.56°C
230.33V
3
10.701A
3.510A
3.436A
1.370A
164.929
89.453%
870
18.5
36.44°C
0.868
12.048V
4.987V
3.346V
5.111V
184.376
42.66°C
230.33V
4
14.853A
4.019A
3.953A
1.569A
219.740
90.237%
970
21.7
36.96°C
0.909
12.020V
4.978V
3.339V
5.099V
243.513
43.51°C
230.33V
5
18.670A
5.036A
4.956A
1.770A
274.646
90.333%
1111
24.6
37.29°C
0.929
12.005V
4.966V
3.330V
5.085V
304.038
44.28°C
230.33V
6
22.495A
6.058A
5.962A
1.972A
329.555
90.198%
1197
28.1
37.94°C
0.944
11.991V
4.954V
3.322V
5.071V
365.370
45.60°C
230.33V
7
26.366A
7.084A
6.974A
2.176A
384.877
89.905%
1328
30.3
38.60°C
0.951
11.976V
4.942V
3.313V
5.057V
428.092
47.04°C
230.33V
8
30.240A
8.115A
7.990A
2.380A
440.178
89.455%
1429
32.5
38.94°C
0.957
11.963V
4.931V
3.304V
5.043V
492.064
47.89°C
230.33V
9
34.499A
8.637A
8.491A
2.384A
494.701
89.032%
1475
33.1
39.36°C
0.963
11.948V
4.922V
3.297V
5.034V
555.643
48.81°C
230.33V
10
38.562A
9.164A
9.028A
2.995A
549.923
88.423%
1475
33.1
39.87°C
0.967
11.934V
4.912V
3.290V
5.011V
621.921
49.88°C
230.33V
11
43.240A
9.177A
9.045A
2.999A
605.142
87.884%
1475
33.1
40.22°C
0.970
11.920V
4.905V
3.284V
5.003V
688.570
51.43°C
230.33V
CL1
0.149A
14.001A
14.000A
0.000A
117.496
80.412%
1385
31.8
37.51°C
0.826
12.046V
4.940V
3.324V
5.125V
146.118
44.32°C
230.33V
CL2
45.845A
1.002A
1.001A
1.000A
560.804
89.224%
1473
33.1
39.80°C
0.968
11.941V
4.962V
3.317V
5.077V
628.537
49.84°C
230.33V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.199A
0.499A
0.475A
0.194A
19.600
77.428%
0
<6.0
0.715
12.087V
5.021V
3.370V
5.164V
25.314
115.12V
2
2.454A
0.997A
0.979A
0.388A
39.988
83.343%
0
<6.0
0.880
12.098V
5.017V
3.367V
5.156V
47.980
115.12V
3
3.652A
1.498A
1.456A
0.583A
59.506
74.972%
764
17.9
0.938
12.075V
5.012V
3.364V
5.148V
79.371
115.12V
4
4.913A
1.999A
1.963A
0.778A
79.904
80.197%
856
17.2
0.950
12.071V
5.006V
3.359V
5.139V
99.635
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.202A
0.498A
0.474A
0.194A
19.630
77.894%
0
<6.0
0.343
12.087V
5.024V
3.372V
5.164V
25.201
230.30V
2
2.456A
0.996A
0.979A
0.388A
40.012
84.255%
0
<6.0
0.517
12.099V
5.019V
3.368V
5.155V
47.489
230.33V
3
3.654A
1.497A
1.455A
0.583A
59.521
76.070%
771
18.2
0.668
12.075V
5.012V
3.364V
5.147V
78.245
230.33V
4
4.912A
2.000A
1.965A
0.779A
79.906
81.593%
818
18.5
0.731
12.070V
5.006V
3.360V
5.139V
97.933
230.33V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
86.6 mV
22.3 mV
16.8 mV
17.9 mV
Pass
20% Load
16.8 mV
20.6 mV
18.2 mV
23.7 mV
Pass
30% Load
29.9 mV
21.9 mV
18.5 mV
21.1 mV
Pass
40% Load
30.3 mV
22.1 mV
19.1 mV
22.9 mV
Pass
50% Load
29.5 mV
23.4 mV
21.3 mV
22.7 mV
Pass
60% Load
28.5 mV
23.2 mV
22.1 mV
23.7 mV
Pass
70% Load
27.0 mV
23.2 mV
24.5 mV
23.7 mV
Pass
80% Load
43.8 mV
24.9 mV
29.5 mV
26.0 mV
Pass
90% Load
27.1 mV
27.4 mV
28.9 mV
25.7 mV
Pass
100% Load
42.8 mV
29.4 mV
32.7 mV
30.3 mV
Pass
110% Load
45.1 mV
29.9 mV
32.0 mV
31.0 mV
Pass
Crossload 1
25.1 mV
32.7 mV
33.8 mV
23.7 mV
Pass
Crossload 2
40.9 mV
26.1 mV
25.3 mV
28.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
86.3 mV
21.7 mV
17.6 mV
17.0 mV
Pass
20% Load
11.8 mV
20.6 mV
34.2 mV
19.6 mV
Pass
30% Load
31.7 mV
22.7 mV
18.4 mV
19.9 mV
Pass
40% Load
30.8 mV
21.2 mV
19.7 mV
19.9 mV
Pass
50% Load
29.2 mV
22.7 mV
20.5 mV
21.8 mV
Pass
60% Load
29.2 mV
22.4 mV
22.8 mV
24.3 mV
Pass
70% Load
27.3 mV
23.9 mV
24.8 mV
24.8 mV
Pass
80% Load
38.1 mV
26.8 mV
28.4 mV
25.7 mV
Pass
90% Load
27.9 mV
24.6 mV
29.7 mV
27.5 mV
Pass
100% Load
42.4 mV
28.3 mV
31.7 mV
30.1 mV
Pass
110% Load
43.4 mV
27.8 mV
31.3 mV
30.7 mV
Pass
Crossload 1
20.8 mV
32.5 mV
32.9 mV
23.4 mV
Pass
Crossload 2
40.9 mV
26.1 mV
23.3 mV
25.8 mV
Pass
The results above are not used in the certification process
Cooler Master MWE Bronze 550
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted