Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan )
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Efficiency Rating
BRONZE
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
87.274%
Average Noise Output (>1450 Load Combinations)
37.41dBA
Average PF (>1450 Load Combinations)
0.917
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1788W
12V Ripple (Full Load)
44.67mV
5V Ripple (Full Load)
29.25mV
3.3V Ripple (Full Load)
28.32mV
5VSB Ripple (Full Load)
32.03mV
12V Load Regulation
1.46%
5V Load Regulation
2.96%
3.3V Load Regulation
2.94%
5VSB Load Regulation
3.73%
Inrush Current
65.413A
Hold-Up Time & Power Ok Signal
28.00ms
AC Loss to PWR_OK Hold Up Time
72.00ms
PWR_OK Inactive to DC Loss Delay
-44.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
129.90%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
28.0
AC Loss to PWR_OK Hold Up Time (ms)
72.0
PWR_OK Inactive to DC Loss Delay (ms)
-44.0
Vampire Power
Tables 230V
Graphs 230V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233
47.262%
0.010
5.179V
0.493
230.33V
2
0.090A
0.466
59.744%
0.015
5.178V
0.780
230.33V
3
0.550A
2.841
77.390%
0.069
5.164V
3.671
230.31V
4
1.000A
5.151
79.124%
0.119
5.150V
6.510
230.32V
5
1.500A
7.703
79.716%
0.168
5.134V
9.663
230.32V
6
3.000A
15.261
79.089%
0.277
5.087V
19.296
230.32V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.960A
2.019A
1.982A
0.974A
69.611
77.066%
1195
26.3
34.19°C
0.720
12.125V
4.954V
3.326V
5.136V
90.327
40.69°C
230.30V
2
8.987A
3.038A
2.983A
1.172A
139.697
85.985%
1325
29.2
34.56°C
0.840
12.107V
4.937V
3.316V
5.120V
162.467
41.64°C
230.30V
3
14.373A
3.554A
3.475A
1.372A
209.595
89.646%
1233
27.6
35.12°C
0.894
12.078V
4.925V
3.307V
5.104V
233.802
42.67°C
230.30V
4
19.776A
4.072A
4.001A
1.573A
279.621
89.929%
1466
32.7
35.67°C
0.924
12.056V
4.912V
3.298V
5.088V
310.936
43.65°C
230.30V
5
24.853A
5.107A
5.017A
1.775A
349.721
89.698%
1822
38.1
36.21°C
0.941
12.040V
4.895V
3.287V
5.071V
389.888
44.56°C
230.30V
6
29.952A
6.150A
6.043A
1.979A
419.848
89.344%
1949
40.2
36.67°C
0.952
12.021V
4.878V
3.276V
5.053V
469.922
45.68°C
230.30V
7
35.064A
7.200A
7.077A
2.185A
489.980
88.758%
2167
42.7
37.28°C
0.959
12.003V
4.861V
3.265V
5.035V
552.038
47.07°C
230.30V
8
40.192A
8.259A
8.115A
2.392A
560.106
88.054%
2334
44.2
37.97°C
0.965
11.985V
4.844V
3.253V
5.017V
636.096
48.51°C
230.30V
9
45.729A
8.798A
8.632A
2.398A
629.841
87.352%
2444
45.9
38.65°C
0.969
11.969V
4.831V
3.244V
5.006V
721.040
49.76°C
230.31V
10
51.057A
9.343A
9.185A
3.016A
699.896
86.471%
2446
45.9
39.82°C
0.971
11.951V
4.817V
3.234V
4.975V
809.398
51.31°C
230.32V
11
56.995A
9.361A
9.208A
3.023A
769.942
85.394%
2443
45.9
40.42°C
0.972
11.935V
4.808V
3.225V
4.963V
901.631
52.76°C
230.32V
CL1
0.147A
14.001A
14.001A
0.000A
115.761
77.104%
2251
43.0
36.55°C
0.822
12.102V
4.855V
3.286V
5.131V
150.136
44.50°C
230.32V
CL2
58.017A
1.003A
0.999A
1.000A
707.102
87.228%
2445
45.9
39.89°C
0.972
11.960V
4.888V
3.262V
5.057V
810.637
51.24°C
230.34V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.192A
0.501A
0.478A
0.194A
19.532
78.003%
0
<6.0
0.364
12.115V
4.975V
3.338V
5.170V
25.040
230.30V
2
2.444A
1.006A
0.986A
0.388A
39.925
84.159%
0
<6.0
0.547
12.126V
4.970V
3.334V
5.160V
47.440
230.31V
3
3.626A
1.513A
1.469A
0.583A
59.369
74.853%
1113
24.0
0.689
12.127V
4.959V
3.329V
5.151V
79.314
230.31V
4
4.884A
2.019A
1.983A
0.778A
79.797
78.817%
1184
25.9
0.747
12.122V
4.953V
3.325V
5.141V
101.243
230.30V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.6 mV
21.4 mV
16.4 mV
18.9 mV
Pass
20% Load
18.0 mV
20.9 mV
16.2 mV
19.9 mV
Pass
30% Load
34.2 mV
22.3 mV
17.0 mV
21.5 mV
Pass
40% Load
32.0 mV
22.6 mV
17.7 mV
22.8 mV
Pass
50% Load
29.0 mV
22.3 mV
17.5 mV
22.5 mV
Pass
60% Load
27.8 mV
22.5 mV
21.0 mV
24.7 mV
Pass
70% Load
27.0 mV
24.1 mV
21.5 mV
25.7 mV
Pass
80% Load
27.8 mV
24.6 mV
24.9 mV
26.4 mV
Pass
90% Load
28.4 mV
24.3 mV
26.5 mV
26.3 mV
Pass
100% Load
44.7 mV
29.3 mV
28.3 mV
32.0 mV
Pass
110% Load
48.0 mV
27.9 mV
28.0 mV
32.9 mV
Pass
Crossload 1
42.5 mV
27.0 mV
32.4 mV
19.9 mV
Pass
Crossload 2
44.7 mV
26.9 mV
18.2 mV
29.5 mV
Pass
The results above are not used in the certification process
Cooler Master MWE 700
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted