Thermal Control DF1202512SELN (120mm, 12V, 0.25A, Rifle Bearing Fan)
5VSB Circuit
Rectifier
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 230V
Efficiency Rating
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
86.127%
Average Noise Output (>1450 Load Combinations)
31.55dBA
Average PF (>1450 Load Combinations)
0.909
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1894W
12V Ripple (Full Load)
47.73mV
5V Ripple (Full Load)
23.21mV
3.3V Ripple (Full Load)
24.34mV
5VSB Ripple (Full Load)
27.89mV
12V Load Regulation
1.52%
5V Load Regulation
2.57%
3.3V Load Regulation
2.77%
5VSB Load Regulation
3.41%
Inrush Current
57.370A
Hold-Up Time & Power Ok Signal
21.00ms
AC Loss to PWR_OK Hold Up Time
19.40ms
PWR_OK Inactive to DC Loss Delay
1.60ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21
AC Loss to PWR_OK Hold Up Time (ms)
19.4
PWR_OK Inactive to DC Loss Delay (ms)
1.6
Vampire Power
Tables 230V
Graphs 230V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
46.521%
0.010
5.177V
0.503
230.25V
2
0.090A
0.466
58.987%
0.015
5.176V
0.790
230.25V
3
0.550A
2.840
76.550%
0.068
5.162V
3.710
230.31V
4
1.000A
5.149
78.443%
0.115
5.148V
6.564
230.31V
5
1.500A
7.701
79.082%
0.161
5.133V
9.738
230.31V
6
3.000A
15.262
78.452%
0.261
5.087V
19.454
230.29V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.306A
2.010A
1.945A
0.974A
49.644
83.549%
0
<6.0
40.85°C
0.616
12.163V
4.976V
3.389V
5.137V
59.419
34.06°C
230.25V
2
5.683A
3.024A
2.929A
1.172A
99.749
86.578%
0
<6.0
41.58°C
0.802
12.115V
4.961V
3.378V
5.121V
115.213
34.47°C
230.25V
3
9.391A
3.539A
3.414A
1.371A
149.640
87.871%
1315
31.8
35.05°C
0.863
12.101V
4.946V
3.367V
5.107V
170.295
42.94°C
230.25V
4
13.115A
4.055A
3.932A
1.571A
199.631
88.347%
1431
32.8
35.59°C
0.917
12.080V
4.932V
3.357V
5.094V
225.962
43.81°C
230.25V
5
16.519A
5.086A
4.929A
1.773A
249.756
88.128%
1450
33.0
36.05°C
0.938
12.062V
4.917V
3.346V
5.078V
283.401
44.86°C
230.25V
6
19.927A
6.119A
5.937A
1.976A
299.830
87.617%
1450
33.0
36.96°C
0.949
12.045V
4.903V
3.336V
5.062V
342.206
46.26°C
230.24V
7
23.348A
7.161A
6.946A
2.181A
349.940
86.906%
1450
33.0
37.21°C
0.956
12.028V
4.889V
3.325V
5.046V
402.663
47.49°C
230.24V
8
26.777A
8.208A
7.963A
2.387A
400.045
85.845%
1454
33.0
37.65°C
0.962
12.012V
4.874V
3.314V
5.029V
466.007
48.57°C
230.24V
9
30.619A
8.741A
8.470A
2.391A
449.757
84.641%
1454
33.0
38.31°C
0.968
11.994V
4.864V
3.305V
5.020V
531.373
49.62°C
230.24V
10
34.233A
9.275A
9.010A
3.006A
499.741
83.664%
1451
33.0
39.37°C
0.972
11.978V
4.852V
3.296V
4.990V
597.320
50.92°C
230.24V
11
38.452A
9.290A
9.030A
3.011A
549.718
83.040%
1455
33.0
40.28°C
0.974
11.963V
4.845V
3.289V
4.984V
661.991
52.36°C
230.24V
CL1
0.133A
13.002A
12.998A
0.000A
108.525
81.791%
1444
32.9
36.15°C
0.832
12.103V
4.882V
3.342V
5.133V
132.685
44.76°C
230.24V
CL2
41.001A
0.999A
0.999A
0.000A
499.637
84.382%
1452
33.0
39.18°C
0.972
11.985V
4.920V
3.329V
5.103V
592.110
50.86°C
230.23V
The results above are not used in the certification process
Light Load Tests 230V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.189A
0.501A
0.471A
0.194A
19.552
78.139%
0
<6.0
0.346
12.152V
4.991V
3.398V
5.168V
25.022
230.25V
2
2.440A
1.001A
0.972A
0.388A
39.980
83.330%
0
<6.0
0.548
12.168V
4.984V
3.394V
5.159V
47.978
230.26V
3
3.626A
1.507A
1.443A
0.583A
59.429
84.874%
0
<6.0
0.669
12.144V
4.978V
3.389V
5.149V
70.020
230.26V
4
4.886A
2.010A
1.949A
0.778A
79.861
86.088%
0
<6.0
0.745
12.131V
4.972V
3.385V
5.139V
92.767
230.26V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
66.2 mV
17.9 mV
12.8 mV
20.0 mV
Pass
20% Load
80.5 mV
18.9 mV
15.2 mV
19.6 mV
Pass
30% Load
32.2 mV
18.2 mV
15.0 mV
16.2 mV
Pass
40% Load
33.1 mV
18.8 mV
15.7 mV
18.2 mV
Pass
50% Load
32.6 mV
19.3 mV
18.0 mV
19.3 mV
Pass
60% Load
32.7 mV
19.9 mV
18.6 mV
21.4 mV
Pass
70% Load
32.2 mV
20.9 mV
20.0 mV
22.0 mV
Pass
80% Load
32.3 mV
20.2 mV
21.8 mV
24.2 mV
Pass
90% Load
32.9 mV
21.0 mV
21.8 mV
25.3 mV
Pass
100% Load
47.7 mV
23.2 mV
24.3 mV
27.9 mV
Pass
110% Load
47.7 mV
24.0 mV
23.9 mV
29.1 mV
Pass
Crossload 1
37.1 mV
23.6 mV
20.8 mV
16.0 mV
Pass
Crossload 2
45.5 mV
22.0 mV
20.4 mV
25.0 mV
Pass
The results above are not used in the certification process
Cooler Master MWE 500
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted