This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
72.785%
0.021
5.108V
0.316
115.11V
2
0.090A
0.460
78.365%
0.039
5.106V
0.587
115.11V
3
0.550A
2.799
82.860%
0.197
5.087V
3.378
115.11V
4
1.000A
5.070
82.965%
0.300
5.069V
6.111
115.12V
5
1.500A
7.575
82.149%
0.373
5.049V
9.221
115.12V
6
3.000A
14.977
78.690%
0.469
4.992V
19.033
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.524%
0.008
5.108V
0.393
230.28V
2
0.090A
0.460
69.173%
0.013
5.106V
0.665
230.28V
3
0.550A
2.799
80.247%
0.067
5.088V
3.488
230.28V
4
1.000A
5.070
81.537%
0.116
5.069V
6.218
230.28V
5
1.500A
7.574
82.121%
0.163
5.048V
9.223
230.29V
6
3.000A
14.977
80.353%
0.274
4.992V
18.639
230.29V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.342A
1.982A
1.976A
0.988A
100.056
84.911%
633
14.2
39.06°C
0.954
12.372V
5.046V
3.335V
5.062V
117.837
42.72°C
115.12V
2
13.658A
2.976A
2.967A
1.189A
199.778
89.633%
633
14.2
39.72°C
0.950
12.365V
5.043V
3.332V
5.048V
222.885
44.14°C
115.12V
3
21.297A
3.472A
3.454A
1.391A
299.284
91.148%
633
14.2
40.50°C
0.967
12.362V
5.042V
3.330V
5.034V
328.351
45.69°C
115.12V
4
29.015A
3.969A
3.966A
1.594A
399.715
91.655%
633
14.2
41.86°C
0.978
12.356V
5.040V
3.328V
5.020V
436.107
47.78°C
115.12V
5
36.384A
4.965A
4.961A
1.798A
499.852
91.666%
633
14.2
42.30°C
0.983
12.350V
5.038V
3.325V
5.006V
545.298
48.86°C
115.12V
6
43.733A
5.961A
5.959A
2.004A
599.958
90.973%
975
27.0
42.90°C
0.988
12.351V
5.035V
3.322V
4.991V
659.490
49.87°C
115.12V
7
51.097A
6.957A
6.959A
2.211A
699.702
90.628%
1194
32.4
43.36°C
0.990
12.341V
5.032V
3.320V
4.976V
772.063
50.91°C
115.12V
8
58.531A
7.956A
7.959A
2.418A
800.159
90.229%
1451
36.9
44.16°C
0.992
12.331V
5.029V
3.317V
4.964V
886.807
52.59°C
115.12V
9
66.303A
8.457A
8.447A
2.421A
899.437
89.688%
1842
43.0
44.79°C
0.993
12.321V
5.027V
3.315V
4.958V
1002.852
53.81°C
115.11V
10
73.929A
8.958A
8.967A
3.045A
999.842
89.060%
2155
47.0
45.54°C
0.994
12.311V
5.024V
3.312V
4.926V
1122.665
55.55°C
115.10V
11
82.087A
8.959A
8.972A
3.049A
1099.874
88.506%
2159
47.0
46.68°C
0.994
12.306V
5.024V
3.310V
4.921V
1242.707
57.84°C
115.09V
CL1
0.141A
16.003A
15.999A
0.000A
135.390
82.180%
632
14.2
42.54°C
0.944
12.377V
5.027V
3.325V
5.089V
164.748
48.67°C
115.12V
CL2
82.823A
1.002A
0.999A
1.000A
1033.170
89.426%
2154
47.0
45.46°C
0.994
12.313V
5.031V
3.317V
5.016V
1155.333
55.43°C
115.09V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.343A
1.983A
1.977A
0.988A
100.087
84.884%
633
14.2
39.05°C
0.771
12.374V
5.045V
3.335V
5.062V
117.911
42.87°C
230.27V
2
13.654A
2.975A
2.971A
1.189A
199.786
90.261%
633
14.2
39.90°C
0.869
12.369V
5.042V
3.332V
5.047V
221.343
44.31°C
230.28V
3
21.281A
3.474A
3.453A
1.391A
299.277
91.943%
633
14.2
40.53°C
0.907
12.371V
5.040V
3.330V
5.034V
325.503
45.57°C
230.27V
4
28.993A
3.970A
3.967A
1.594A
399.698
92.836%
633
14.2
41.95°C
0.925
12.365V
5.038V
3.327V
5.020V
430.542
47.60°C
230.28V
5
36.362A
4.965A
4.962A
1.798A
499.829
93.109%
715
18.4
42.16°C
0.940
12.357V
5.036V
3.325V
5.006V
536.823
48.39°C
230.28V
6
43.739A
5.962A
5.960A
2.004A
599.942
93.126%
929
25.6
42.81°C
0.950
12.349V
5.033V
3.322V
4.991V
644.229
49.56°C
230.29V
7
51.105A
6.960A
6.959A
2.211A
699.693
92.995%
1142
31.1
43.04°C
0.955
12.339V
5.030V
3.319V
4.976V
752.396
50.79°C
230.29V
8
58.550A
7.959A
7.961A
2.418A
800.213
92.749%
1458
37.0
43.76°C
0.960
12.328V
5.027V
3.316V
4.963V
862.769
52.11°C
230.29V
9
66.324A
8.461A
8.449A
2.421A
899.496
92.495%
1798
42.3
44.46°C
0.965
12.318V
5.025V
3.314V
4.957V
972.476
53.91°C
230.29V
10
73.943A
8.963A
8.971A
3.046A
999.894
92.142%
2154
47.0
45.31°C
0.969
12.309V
5.022V
3.312V
4.926V
1085.171
55.50°C
230.28V
11
82.107A
8.965A
8.972A
3.049A
1099.876
91.908%
2156
47.0
46.66°C
0.972
12.303V
5.021V
3.310V
4.921V
1196.715
57.72°C
230.27V
CL1
0.147A
16.003A
15.998A
0.000A
135.396
82.674%
633
14.2
42.27°C
0.828
12.375V
5.024V
3.324V
5.088V
163.771
48.32°C
230.26V
CL2
82.828A
1.002A
1.000A
1.000A
1033.317
92.562%
2156
47.0
45.65°C
0.970
12.314V
5.031V
3.317V
5.014V
1116.352
55.88°C
230.26V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.164A
0.496A
0.477A
0.196A
19.504
60.233%
633
14.2
0.791
12.382V
5.042V
3.336V
5.100V
32.381
115.11V
2
2.397A
0.991A
0.988A
0.393A
39.973
73.824%
633
14.2
0.881
12.381V
5.045V
3.336V
5.091V
54.146
115.11V
3
3.559A
1.486A
1.468A
0.591A
59.461
79.502%
633
14.2
0.912
12.379V
5.048V
3.337V
5.081V
74.792
115.12V
4
4.784A
1.982A
1.978A
0.789A
79.813
82.713%
633
14.2
0.944
12.377V
5.047V
3.336V
5.071V
96.494
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.173A
0.494A
0.479A
0.196A
19.603
53.436%
633
14.2
0.455
12.375V
5.040V
3.335V
5.100V
36.685
230.27V
2
2.402A
0.992A
0.991A
0.393A
40.038
70.781%
633
14.2
0.575
12.377V
5.043V
3.335V
5.090V
56.566
230.27V
3
3.563A
1.486A
1.470A
0.591A
59.501
76.903%
633
14.2
0.662
12.376V
5.046V
3.336V
5.081V
77.371
230.28V
4
4.788A
1.983A
1.975A
0.789A
79.848
82.164%
633
14.2
0.724
12.376V
5.045V
3.335V
5.071V
97.181
230.28V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.9 mV
16.8 mV
17.3 mV
17.6 mV
Pass
20% Load
16.8 mV
17.4 mV
18.0 mV
15.8 mV
Pass
30% Load
18.9 mV
17.3 mV
19.7 mV
17.3 mV
Pass
40% Load
20.5 mV
18.2 mV
19.6 mV
17.0 mV
Pass
50% Load
22.3 mV
19.1 mV
20.6 mV
16.6 mV
Pass
60% Load
19.5 mV
19.5 mV
20.6 mV
18.2 mV
Pass
70% Load
21.5 mV
21.2 mV
23.2 mV
19.3 mV
Pass
80% Load
23.4 mV
21.2 mV
23.8 mV
19.8 mV
Pass
90% Load
25.8 mV
22.5 mV
25.2 mV
20.4 mV
Pass
100% Load
29.0 mV
25.1 mV
26.7 mV
22.2 mV
Pass
110% Load
30.1 mV
25.7 mV
27.0 mV
23.3 mV
Pass
Crossload 1
15.9 mV
21.9 mV
24.8 mV
17.0 mV
Pass
Crossload 2
28.7 mV
22.9 mV
21.5 mV
19.5 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.9 mV
16.5 mV
15.6 mV
12.9 mV
Pass
20% Load
13.2 mV
18.7 mV
17.2 mV
14.2 mV
Pass
30% Load
13.7 mV
18.9 mV
18.2 mV
16.0 mV
Pass
40% Load
16.1 mV
20.3 mV
20.3 mV
16.2 mV
Pass
50% Load
16.7 mV
20.8 mV
18.9 mV
18.4 mV
Pass
60% Load
17.2 mV
20.8 mV
20.3 mV
16.4 mV
Pass
70% Load
19.7 mV
21.8 mV
21.6 mV
17.2 mV
Pass
80% Load
21.4 mV
22.3 mV
23.5 mV
18.5 mV
Pass
90% Load
22.4 mV
23.9 mV
24.3 mV
18.4 mV
Pass
100% Load
27.4 mV
24.7 mV
24.0 mV
19.5 mV
Pass
110% Load
30.2 mV
24.4 mV
25.2 mV
19.9 mV
Pass
Crossload 1
17.1 mV
21.2 mV
23.9 mV
16.1 mV
Pass
Crossload 2
27.7 mV
21.7 mV
19.9 mV
17.4 mV
Pass
The results above are not used in the certification process
Cooler Master V1000 Platinum
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted