This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
68.843%
0.055
5.152V
0.337
115.09V
2
0.090A
0.464
73.418%
0.100
5.151V
0.632
115.09V
3
0.550A
2.829
77.528%
0.335
5.143V
3.649
115.09V
4
1.000A
5.136
77.560%
0.403
5.136V
6.622
115.09V
5
1.500A
7.692
77.799%
0.437
5.127V
9.887
115.09V
6
3.000A
15.290
76.032%
0.481
5.096V
20.110
115.08V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
62.534%
0.018
5.152V
0.371
230.26V
2
0.090A
0.464
68.945%
0.033
5.151V
0.673
230.26V
3
0.550A
2.829
76.171%
0.161
5.142V
3.714
230.24V
4
1.000A
5.136
77.013%
0.242
5.135V
6.669
230.24V
5
1.500A
7.690
76.977%
0.297
5.126V
9.990
230.25V
6
3.001A
15.306
78.044%
0.371
5.101V
19.612
230.25V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.333A
2.000A
1.984A
0.975A
49.518
83.324%
0
<6.0
43.89°C
0.934
11.973V
4.999V
3.320V
5.128V
59.428
39.40°C
115.09V
2
5.739A
3.002A
2.980A
1.172A
99.611
88.256%
0
<6.0
44.38°C
0.972
11.975V
4.996V
3.318V
5.119V
112.866
39.75°C
115.09V
3
9.480A
3.503A
3.465A
1.370A
149.523
89.764%
0
<6.0
45.16°C
0.981
11.976V
4.995V
3.317V
5.110V
166.574
40.07°C
115.08V
4
13.223A
4.004A
3.980A
1.568A
199.550
89.821%
939
19.8
40.60°C
0.985
11.976V
4.994V
3.316V
5.101V
222.163
45.94°C
115.09V
5
16.630A
5.007A
4.976A
1.768A
249.682
89.851%
1014
23.2
41.18°C
0.988
11.977V
4.994V
3.315V
5.093V
277.886
46.78°C
115.09V
6
20.034A
6.007A
5.973A
1.967A
299.761
89.414%
1338
33.2
41.95°C
0.987
11.978V
4.993V
3.315V
5.084V
335.249
47.87°C
115.09V
7
23.441A
7.010A
6.969A
2.168A
349.889
88.914%
1489
36.7
42.31°C
0.988
11.979V
4.992V
3.314V
5.074V
393.514
48.36°C
115.09V
8
26.851A
8.016A
7.966A
2.370A
400.017
88.317%
1797
41.5
42.71°C
0.989
11.978V
4.990V
3.313V
5.065V
452.931
48.86°C
115.09V
9
30.657A
8.523A
8.452A
2.373A
449.759
87.826%
2028
44.1
43.11°C
0.990
11.979V
4.989V
3.312V
5.059V
512.105
49.77°C
115.12V
10
34.231A
9.024A
8.971A
2.975A
499.788
87.232%
2082
44.1
44.26°C
0.991
11.980V
4.987V
3.310V
5.043V
572.942
51.03°C
115.13V
11
38.404A
9.027A
8.971A
2.978A
549.815
86.720%
2084
44.1
46.09°C
0.992
11.981V
4.986V
3.309V
5.038V
634.013
53.27°C
115.12V
CL1
0.140A
12.000A
11.998A
0.000A
101.367
83.622%
1245
31.4
41.74°C
0.973
11.977V
4.995V
3.313V
5.124V
121.220
46.13°C
115.18V
CL2
41.008A
1.004A
0.997A
1.000A
504.765
88.169%
2089
44.1
44.76°C
0.991
11.982V
4.992V
3.317V
5.088V
572.496
51.15°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.340A
2.000A
1.985A
0.975A
49.602
84.250%
0
<6.0
45.02°C
0.712
11.972V
4.999V
3.320V
5.127V
58.875
39.46°C
230.26V
2
5.745A
3.002A
2.982A
1.173A
99.691
89.362%
0
<6.0
45.34°C
0.856
11.975V
4.996V
3.318V
5.117V
111.559
39.59°C
230.27V
3
9.489A
3.503A
3.465A
1.370A
149.621
90.559%
935
19.7
40.45°C
0.907
11.975V
4.995V
3.317V
5.109V
165.219
46.43°C
230.28V
4
13.231A
4.005A
3.981A
1.569A
199.644
91.417%
941
19.9
40.85°C
0.934
11.975V
4.994V
3.316V
5.100V
218.388
46.93°C
230.28V
5
16.640A
5.007A
4.977A
1.768A
249.769
91.666%
1010
23.2
41.38°C
0.948
11.975V
4.994V
3.315V
5.092V
272.476
47.77°C
230.29V
6
20.042A
6.010A
5.973A
1.968A
299.844
91.419%
1375
33.2
41.89°C
0.958
11.977V
4.992V
3.314V
5.083V
327.988
48.39°C
230.29V
7
23.450A
7.013A
6.970A
2.169A
349.993
91.100%
1624
41.8
42.05°C
0.964
11.978V
4.992V
3.314V
5.072V
384.184
49.17°C
230.30V
8
26.857A
8.015A
7.969A
2.370A
400.091
90.837%
1846
42.3
42.74°C
0.969
11.978V
4.990V
3.313V
5.064V
440.449
49.90°C
230.30V
9
30.665A
8.520A
8.454A
2.373A
449.805
90.598%
2039
44.2
43.80°C
0.972
11.978V
4.989V
3.311V
5.058V
496.483
51.26°C
230.31V
10
34.239A
9.023A
8.972A
2.975A
499.846
90.273%
2078
45.4
44.20°C
0.975
11.979V
4.987V
3.310V
5.043V
553.705
52.40°C
230.31V
11
38.412A
9.027A
8.974A
2.978A
549.873
90.045%
2084
44.1
46.25°C
0.977
11.980V
4.985V
3.309V
5.038V
610.667
54.73°C
230.32V
CL1
0.144A
11.999A
12.001A
0.000A
101.419
84.659%
1277
30.1
41.70°C
0.866
11.976V
4.995V
3.313V
5.123V
119.797
47.97°C
230.32V
CL2
41.014A
1.003A
0.999A
1.000A
504.797
91.227%
2081
44.1
44.03°C
0.975
11.981V
4.992V
3.317V
5.088V
553.344
52.42°C
230.32V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.499A
0.477A
0.194A
19.373
73.341%
0
<6.0
0.816
11.967V
5.008V
3.326V
5.146V
26.415
115.08V
2
2.466A
0.997A
0.989A
0.389A
39.796
82.532%
0
<6.0
0.919
11.971V
5.004V
3.324V
5.140V
48.219
115.08V
3
3.668A
1.499A
1.471A
0.584A
59.298
86.131%
0
<6.0
0.949
11.973V
5.001V
3.321V
5.135V
68.846
115.08V
4
4.936A
2.000A
1.987A
0.780A
79.698
87.354%
0
<6.0
0.962
11.974V
4.999V
3.320V
5.129V
91.236
115.08V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
2.882A
0.501A
0.477A
0.195A
39.578
83.708%
0
<6.0
0.654
11.964V
5.007V
3.326V
5.143V
47.281
230.25V
2
4.149A
1.000A
0.990A
0.389A
59.961
87.164%
0
<6.0
0.749
11.971V
5.003V
3.324V
5.137V
68.791
230.25V
3
5.348A
1.499A
1.474A
0.585A
79.419
88.852%
0
<6.0
0.813
11.972V
5.000V
3.321V
5.132V
89.383
230.24V
4
6.615A
2.000A
1.986A
0.780A
99.793
89.979%
0
<6.0
0.855
11.974V
4.998V
3.319V
5.126V
110.907
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
11.8 mV
9.2 mV
14.2 mV
9.8 mV
Pass
20% Load
13.5 mV
10.8 mV
15.1 mV
10.1 mV
Pass
30% Load
12.5 mV
11.9 mV
15.7 mV
10.4 mV
Pass
40% Load
12.6 mV
12.8 mV
16.0 mV
10.4 mV
Pass
50% Load
13.4 mV
14.7 mV
16.8 mV
10.7 mV
Pass
60% Load
14.8 mV
16.5 mV
17.8 mV
11.2 mV
Pass
70% Load
15.7 mV
17.7 mV
19.1 mV
11.6 mV
Pass
80% Load
17.1 mV
20.8 mV
21.6 mV
12.6 mV
Pass
90% Load
17.8 mV
22.7 mV
23.4 mV
12.8 mV
Pass
100% Load
26.3 mV
23.7 mV
23.9 mV
14.6 mV
Pass
110% Load
27.4 mV
24.7 mV
24.8 mV
15.6 mV
Pass
Crossload 1
22.0 mV
21.9 mV
23.2 mV
10.2 mV
Pass
Crossload 2
24.8 mV
14.5 mV
17.7 mV
13.4 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.9 mV
9.0 mV
14.7 mV
9.2 mV
Pass
20% Load
12.7 mV
10.5 mV
16.3 mV
9.4 mV
Pass
30% Load
11.7 mV
11.3 mV
15.4 mV
10.1 mV
Pass
40% Load
12.3 mV
12.3 mV
17.1 mV
10.7 mV
Pass
50% Load
12.8 mV
14.4 mV
16.9 mV
10.6 mV
Pass
60% Load
13.4 mV
15.8 mV
18.6 mV
11.4 mV
Pass
70% Load
14.6 mV
18.0 mV
44.5 mV
28.1 mV
Pass
80% Load
16.1 mV
20.7 mV
22.0 mV
11.6 mV
Pass
90% Load
16.9 mV
21.4 mV
22.8 mV
11.9 mV
Pass
100% Load
26.8 mV
24.2 mV
22.9 mV
13.0 mV
Pass
110% Load
27.6 mV
24.7 mV
24.1 mV
13.6 mV
Pass
Crossload 1
20.9 mV
21.2 mV
22.7 mV
10.1 mV
Pass
Crossload 2
24.8 mV
14.3 mV
17.9 mV
12.5 mV
Pass
The results above are not used in the certification process
SeaSonic Focus SGX 500W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted