This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
Noise Graph
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU’s efficiency under high ambient temperatures
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
70.000%
0.020
5.134V
0.330
115.11V
2
0.090A
0.462
75.244%
0.038
5.133V
0.614
115.10V
3
0.550A
2.816
79.706%
0.192
5.119V
3.533
115.10V
4
1.000A
5.106
80.107%
0.293
5.106V
6.374
115.11V
5
1.500A
7.638
80.341%
0.363
5.091V
9.507
115.11V
6
3.000A
15.115
79.057%
0.458
5.038V
19.119
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232
62.703%
0.008
5.133V
0.370
230.25V
2
0.090A
0.462
70.000%
0.013
5.132V
0.660
230.25V
3
0.550A
2.816
77.512%
0.071
5.120V
3.633
230.25V
4
1.000A
5.107
78.897%
0.122
5.106V
6.473
230.25V
5
1.500A
7.638
79.829%
0.170
5.091V
9.568
230.25V
6
3.000A
15.134
80.282%
0.276
5.045V
18.851
230.25V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.340A
1.980A
1.987A
0.981A
74.427
86.705%
0
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.344A
1.979A
1.987A
0.981A
74.457
87.661%
0
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.187A
0.495A
0.480A
0.195A
19.562
72.984%
0
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.187A
0.494A
0.481A
0.195A
19.545
73.419%
0
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
3.3 mV
2.6 mV
2.9 mV
2.6 mV
Pass
20% Load
4.1 mV
3.6 mV
3.7 mV
2.9 mV
Pass
30% Load
4.2 mV
4.1 mV
4.5 mV
3.5 mV
Pass
40% Load
5.3 mV
5.1 mV
5.6 mV
3.2 mV
Pass
50% Load
5.3 mV
6.3 mV
6.9 mV
3.8 mV
Pass
60% Load
5.8 mV
7.0 mV
8.1 mV
5.0 mV
Pass
70% Load
6.2 mV
7.7 mV
9.3 mV
7.1 mV
Pass
80% Load
6.4 mV
8.5 mV
10.8 mV
7.4 mV
Pass
90% Load
6.7 mV
9.0 mV
12.0 mV
8.9 mV
Pass
100% Load
9.1 mV
10.0 mV
13.2 mV
9.8 mV
Pass
107% Load
9.8 mV
9.8 mV
12.7 mV
11.3 mV
Pass
Crossload 1
4.7 mV
5.5 mV
6.4 mV
20.5 mV
Pass
Crossload 2
9.5 mV
9.2 mV
9.8 mV
7.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
3.7 mV
2.9 mV
2.8 mV
2.6 mV
Pass
20% Load
4.0 mV
3.4 mV
3.8 mV
3.1 mV
Pass
30% Load
4.7 mV
4.1 mV
4.5 mV
3.0 mV
Pass
40% Load
5.1 mV
4.9 mV
5.6 mV
3.1 mV
Pass
50% Load
5.1 mV
6.3 mV
6.8 mV
3.5 mV
Pass
60% Load
5.7 mV
6.9 mV
8.0 mV
4.1 mV
Pass
70% Load
6.1 mV
7.4 mV
8.2 mV
7.0 mV
Pass
80% Load
6.0 mV
8.5 mV
10.7 mV
6.5 mV
Pass
90% Load
6.5 mV
9.1 mV
11.0 mV
7.3 mV
Pass
100% Load
8.9 mV
9.7 mV
13.0 mV
8.6 mV
Pass
110% Load
9.3 mV
10.1 mV
12.0 mV
9.2 mV
Pass
Crossload 1
4.2 mV
5.4 mV
6.6 mV
19.5 mV
Pass
Crossload 2
9.2 mV
9.5 mV
10.1 mV
5.4 mV
Pass
The results above are not used in the certification process
Super Flower Leadex III Gold 750W rev.1
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted