This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.047A
0.242
69.341%
0.029
5.147V
0.349
115.08V
2
0.093A
0.479
75.791%
0.053
5.146V
0.632
115.08V
3
0.552A
2.833
81.245%
0.228
5.133V
3.487
115.08V
4
2.502A
12.703
78.423%
0.421
5.077V
16.198
115.07V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.323A
1.973A
1.963A
0.976A
49.776
86.006%
580
20.8
37.07°C
0.930
12.140V
5.066V
3.358V
5.109V
57.875
41.44°C
115.05V
2
5.679A
2.958A
2.952A
1.177A
99.758
90.413%
580
20.8
38.46°C
0.963
12.135V
5.059V
3.348V
5.094V
110.336
43.09°C
115.04V
3
9.384A
3.465A
3.470A
1.376A
149.914
91.522%
580
20.8
39.29°C
0.972
12.130V
5.052V
3.340V
5.080V
163.801
44.16°C
115.04V
4
13.081A
3.963A
3.959A
1.576A
199.768
91.853%
600
21.4
39.20°C
0.973
12.124V
5.045V
3.333V
5.066V
217.487
44.62°C
115.04V
5
16.445A
4.970A
4.964A
1.781A
249.787
91.768%
720
24.5
39.58°C
0.976
12.118V
5.034V
3.322V
5.051V
272.194
45.44°C
115.06V
6
19.806A
5.971A
5.975A
1.985A
299.700
91.446%
920
31.7
40.27°C
0.981
12.113V
5.024V
3.313V
5.036V
327.734
46.44°C
115.05V
7
23.178A
6.981A
6.990A
2.191A
349.729
91.042%
930
32.1
41.48°C
0.985
12.107V
5.017V
3.303V
5.021V
384.142
48.22°C
115.07V
8
26.542A
7.991A
8.013A
2.396A
399.654
89.748%
940
32.3
41.99°C
0.990
12.104V
5.007V
3.293V
5.005V
445.307
50.47°C
115.07V
9
30.346A
8.502A
8.558A
2.402A
449.682
89.381%
940
32.3
42.92°C
0.992
12.097V
4.999V
3.282V
4.995V
503.106
53.08°C
115.08V
10
34.101A
9.028A
9.064A
2.504A
499.564
88.876%
940
32.3
43.77°C
0.994
12.092V
4.989V
3.276V
4.984V
562.091
54.59°C
115.08V
11
38.249A
9.038A
9.080A
2.512A
549.573
88.290%
940
32.3
44.78°C
0.995
12.088V
4.983V
3.269V
4.976V
622.462
59.10°C
115.08V
CL1
0.099A
12.011A
12.003A
0.005A
101.674
86.913%
940
32.3
43.57°C
0.966
12.139V
5.038V
3.327V
5.107V
116.984
50.52°C
115.08V
CL2
40.958A
1.003A
1.001A
1.003A
508.577
89.619%
940
32.3
44.27°C
0.994
12.090V
5.012V
3.301V
5.048V
567.489
57.19°C
115.08V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.207A
0.491A
0.475A
0.191A
19.73
76.855%
580
20.8
0.844
12.142V
5.074V
3.367V
5.139V
25.67
115.06V
2
2.429A
0.978A
0.980A
0.386A
39.72
85.084%
580
20.8
0.918
12.139V
5.070V
3.361V
5.129V
46.68
115.06V
3
3.660A
1.473A
1.485A
0.586A
59.88
88.300%
580
20.8
0.940
12.138V
5.066V
3.359V
5.120V
67.81
115.05V
4
4.878A
1.973A
1.965A
0.781A
79.77
89.794%
580
20.8
0.961
12.136V
5.063V
3.354V
5.111V
88.84
115.05V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.0 mV
9.4 mV
9.1 mV
9.7 mV
Pass
20% Load
21.0 mV
10.8 mV
11.4 mV
9.8 mV
Pass
30% Load
23.7 mV
13.8 mV
12.8 mV
10.8 mV
Pass
40% Load
26.0 mV
16.4 mV
14.0 mV
19.3 mV
Pass
50% Load
28.7 mV
18.4 mV
15.3 mV
14.3 mV
Pass
60% Load
30.5 mV
19.2 mV
17.0 mV
15.8 mV
Pass
70% Load
33.1 mV
18.6 mV
18.5 mV
17.6 mV
Pass
80% Load
37.9 mV
23.9 mV
20.2 mV
19.0 mV
Pass
90% Load
38.9 mV
26.6 mV
21.3 mV
19.3 mV
Pass
100% Load
41.6 mV
29.5 mV
25.4 mV
21.3 mV
Pass
110% Load
43.0 mV
29.8 mV
26.5 mV
21.4 mV
Pass
Crossload 1
29.3 mV
16.6 mV
19.9 mV
11.5 mV
Pass
Crossload 2
34.8 mV
23.7 mV
20.9 mV
15.4 mV
Pass
The results above are not used in the certification process
Enermax Platimax D.F. 500W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted