This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
66.667%
0.043
5.104V
0.345
115.05V
2
0.090A
0.460
72.785%
0.077
5.102V
0.632
115.05V
3
0.550A
2.795
79.246%
0.252
5.080V
3.527
115.06V
4
1.000A
5.060
79.585%
0.299
5.060V
6.358
115.05V
5
1.500A
7.556
79.545%
0.324
5.037V
9.499
115.05V
6
3.000A
14.887
76.777%
0.360
4.962V
19.390
115.04V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.524%
0.017
5.104V
0.393
230.20V
2
0.090A
0.460
65.341%
0.029
5.102V
0.704
230.02V
3
0.550A
2.794
75.087%
0.133
5.080V
3.721
230.20V
4
1.000A
5.060
77.655%
0.192
5.059V
6.516
230.20V
5
1.500A
7.555
77.774%
0.233
5.036V
9.714
230.18V
6
3.000A
14.895
76.739%
0.286
4.965V
19.410
230.20V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.560A
1.970A
1.968A
0.994A
64.889
85.816%
0
<6.0
48.34°C
0.946
12.160V
5.078V
3.351V
5.032V
75.614
40.47°C
115.06V
2
8.109A
2.961A
2.966A
1.197A
129.390
89.713%
687
13.7
40.88°C
0.977
12.145V
5.067V
3.338V
5.014V
144.226
49.23°C
115.06V
3
13.059A
3.462A
3.459A
1.402A
194.464
91.167%
585
9.6
41.09°C
0.985
12.134V
5.056V
3.325V
4.994V
213.306
50.02°C
115.06V
4
18.029A
3.966A
3.983A
1.609A
259.687
91.524%
580
9.5
41.71°C
0.994
12.118V
5.045V
3.314V
4.974V
283.738
51.23°C
115.05V
5
22.676A
4.969A
5.001A
1.817A
324.980
91.064%
575
9.5
42.30°C
0.994
12.104V
5.033V
3.299V
4.954V
356.870
52.44°C
115.05V
6
27.270A
5.976A
6.028A
2.027A
389.503
90.481%
830
19.4
42.53°C
0.994
12.090V
5.021V
3.285V
4.934V
430.481
53.45°C
115.05V
7
31.941A
6.990A
7.063A
2.239A
454.760
89.849%
1020
26.2
43.37°C
0.995
12.074V
5.008V
3.270V
4.914V
506.139
54.81°C
115.05V
8
36.617A
8.007A
8.111A
2.453A
520.081
89.129%
1150
30.0
43.57°C
0.996
12.062V
4.996V
3.255V
4.893V
583.514
55.46°C
115.04V
9
41.720A
8.530A
8.632A
2.457A
584.994
88.497%
1415
36.1
44.75°C
0.996
12.044V
4.985V
3.243V
4.885V
661.033
56.80°C
115.04V
10
46.549A
9.051A
9.196A
3.102A
649.842
87.655%
1430
36.3
45.63°C
0.997
12.033V
4.974V
3.229V
4.837V
741.364
58.22°C
115.04V
11
51.991A
9.066A
9.222A
3.108A
714.651
86.935%
1430
36.3
46.57°C
0.997
12.020V
4.966V
3.220V
4.827V
822.051
59.73°C
115.04V
CL1
0.142A
14.002A
13.999A
0.000A
118.128
82.280%
695
13.8
42.39°C
0.978
12.152V
5.033V
3.281V
5.092V
143.569
52.47°C
115.06V
CL2
54.172A
1.003A
0.999A
1.000A
665.100
88.437%
1430
36.3
45.34°C
0.997
12.033V
5.007V
3.275V
4.954V
752.060
58.34°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.557A
1.967A
1.968A
0.994A
64.854
86.629%
0
<6.0
46.76°C
0.790
12.163V
5.079V
3.352V
5.033V
74.864
40.25°C
230.03V
2
8.108A
2.961A
2.965A
1.197A
129.350
90.583%
687
13.7
40.75°C
0.884
12.143V
5.066V
3.337V
5.013V
142.797
47.78°C
230.21V
3
13.059A
3.461A
3.458A
1.402A
194.438
92.458%
585
9.6
41.34°C
0.911
12.133V
5.055V
3.325V
4.993V
210.299
48.89°C
230.03V
4
18.027A
3.964A
3.982A
1.609A
259.648
92.656%
580
9.5
41.65°C
0.916
12.118V
5.045V
3.314V
4.973V
280.227
49.80°C
230.20V
5
22.676A
4.968A
5.000A
1.817A
324.887
92.467%
575
9.5
42.31°C
0.955
12.100V
5.033V
3.300V
4.955V
351.356
50.94°C
230.21V
6
27.270A
5.979A
6.028A
2.027A
389.479
92.076%
830
19.4
42.55°C
0.972
12.089V
5.020V
3.284V
4.934V
422.997
51.67°C
230.20V
7
31.940A
6.991A
7.067A
2.240A
454.825
91.697%
1020
26.2
43.21°C
0.976
12.076V
5.008V
3.269V
4.913V
496.010
52.68°C
230.02V
8
36.617A
8.009A
8.113A
2.453A
520.126
91.168%
1150
30.0
43.63°C
0.983
12.063V
4.996V
3.254V
4.893V
570.514
53.67°C
230.02V
9
41.713A
8.528A
8.635A
2.458A
585.067
90.549%
1417
36.2
44.47°C
0.989
12.048V
4.985V
3.242V
4.883V
646.133
55.20°C
230.03V
10
46.554A
9.051A
9.200A
3.103A
649.898
89.922%
1430
36.3
45.78°C
0.991
12.033V
4.973V
3.228V
4.836V
722.733
57.16°C
230.19V
11
52.000A
9.067A
9.229A
3.109A
714.718
89.412%
1422
36.2
46.66°C
0.993
12.019V
4.965V
3.219V
4.826V
799.352
58.63°C
230.19V
CL1
0.144A
14.003A
14.000A
0.000A
118.147
82.901%
695
13.8
42.85°C
0.880
12.151V
5.032V
3.281V
5.092V
142.516
51.65°C
230.21V
CL2
54.178A
1.000A
1.001A
1.000A
665.109
90.773%
1425
36.3
45.35°C
0.992
12.032V
5.007V
3.275V
4.954V
732.720
57.27°C
230.19V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.186A
0.493A
0.475A
0.197A
19.568
68.093%
0
<6.0
0.870
12.192V
5.089V
3.366V
5.080V
28.737
115.06V
2
2.439A
0.983A
0.981A
0.395A
39.982
81.302%
0
<6.0
0.916
12.171V
5.085V
3.361V
5.067V
49.177
115.05V
3
3.625A
1.476A
1.461A
0.594A
59.505
85.335%
0
<6.0
0.943
12.165V
5.082V
3.356V
5.055V
69.731
115.05V
4
4.876A
1.970A
1.969A
0.794A
79.905
87.469%
0
<6.0
0.957
12.162V
5.078V
3.350V
5.042V
91.352
115.06V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.184A
0.490A
0.476A
0.197A
19.542
68.939%
0
<6.0
0.547
12.199V
5.092V
3.367V
5.083V
28.347
230.21V
2
2.434A
0.983A
0.982A
0.395A
39.936
82.281%
0
<6.0
0.696
12.174V
5.087V
3.361V
5.070V
48.536
230.20V
3
3.622A
1.475A
1.458A
0.594A
59.453
85.936%
0
<6.0
0.776
12.165V
5.082V
3.356V
5.056V
69.183
230.21V
4
4.871A
1.970A
1.969A
0.794A
79.822
88.120%
0
<6.0
0.825
12.158V
5.077V
3.350V
5.042V
90.583
230.21V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.0 mV
9.6 mV
9.3 mV
16.0 mV
Pass
20% Load
23.7 mV
10.5 mV
10.3 mV
17.6 mV
Pass
30% Load
26.9 mV
11.5 mV
11.1 mV
19.7 mV
Pass
40% Load
27.9 mV
13.2 mV
15.8 mV
19.7 mV
Pass
50% Load
31.0 mV
15.0 mV
17.7 mV
20.1 mV
Pass
60% Load
37.7 mV
17.3 mV
34.0 mV
21.8 mV
Pass
70% Load
36.5 mV
19.7 mV
16.9 mV
32.1 mV
Pass
80% Load
39.2 mV
21.4 mV
17.9 mV
27.9 mV
Pass
90% Load
41.0 mV
23.9 mV
28.2 mV
30.1 mV
Pass
100% Load
45.1 mV
29.9 mV
33.9 mV
28.4 mV
Pass
110% Load
47.2 mV
31.7 mV
39.7 mV
30.2 mV
Pass
Crossload 1
36.2 mV
17.4 mV
11.9 mV
15.1 mV
Pass
Crossload 2
37.4 mV
26.8 mV
38.9 mV
33.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
28.0 mV
6.3 mV
6.8 mV
4.1 mV
Pass
20% Load
21.4 mV
7.3 mV
9.0 mV
4.7 mV
Pass
30% Load
11.3 mV
9.3 mV
10.6 mV
7.2 mV
Pass
40% Load
11.5 mV
9.3 mV
10.2 mV
6.2 mV
Pass
50% Load
12.0 mV
11.1 mV
11.2 mV
6.9 mV
Pass
60% Load
12.3 mV
15.1 mV
14.1 mV
10.2 mV
Pass
70% Load
13.2 mV
13.5 mV
13.4 mV
8.4 mV
Pass
80% Load
14.1 mV
15.1 mV
15.2 mV
9.2 mV
Pass
90% Load
15.6 mV
16.4 mV
16.6 mV
10.3 mV
Pass
100% Load
16.9 mV
18.3 mV
17.0 mV
11.5 mV
Pass
110% Load
19.0 mV
19.6 mV
17.8 mV
12.0 mV
Pass
Crossload 1
21.7 mV
13.4 mV
14.6 mV
6.9 mV
Pass
Crossload 2
17.6 mV
13.0 mV
12.1 mV
9.1 mV
Pass
The results above are not used in the certification process
Thermaltake Toughpower Grand Gold 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted