ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
BRONZE
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
82.415%
Average Noise Output (>1450 Load Combinations)
33.90dBA
Average PF (>1450 Load Combinations)
0.984
Efficiency With 10W (≤500W) or 2% (>500W) Load
58.384%
Standby Power Consumption
0.0588W
12V Ripple (Full Load)
39.42mV
5V Ripple (Full Load)
34.08mV
3.3V Ripple (Full Load)
41.02mV
5VSB Ripple (Full Load)
19.42mV
12V Load Regulation
1.32%
5V Load Regulation
2.04%
3.3V Load Regulation
1.97%
5VSB Load Regulation
3.52%
Inrush Current
97.207A
Efficiency Rating
BRONZE
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
84.696%
Average Noise Output (>1450 Load Combinations)
33.67dBA
Average PF (>1450 Load Combinations)
0.944
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1446W
12V Ripple (Full Load)
33.36mV
5V Ripple (Full Load)
27.36mV
3.3V Ripple (Full Load)
37.68mV
5VSB Ripple (Full Load)
17.26mV
12V Load Regulation
1.27%
5V Load Regulation
2.23%
3.3V Load Regulation
1.88%
5VSB Load Regulation
3.42%
Inrush Current
80.321A
Hold-Up Time & Power Ok Signal
16.90ms
AC Loss to PWR_OK Hold Up Time
28.30ms
PWR_OK Inactive to DC Loss Delay
-11.40ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.90
AC Loss to PWR_OK Hold Up Time (ms)
28.30
PWR_OK Inactive to DC Loss Delay (ms)
-11.40
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
64.641%
0.029
5.188V
0.362
115.38V
2
0.090A
0.468
69.851%
0.053
5.186V
0.670
115.37V
3
0.550A
2.843
76.322%
0.242
5.168V
3.725
115.37V
4
1.000A
5.149
76.383%
0.341
5.148V
6.741
115.35V
5
1.500A
7.689
76.447%
0.399
5.125V
10.058
115.36V
6
2.501A
12.676
75.336%
0.457
5.069V
16.826
115.35V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.234
50.540%
0.013
5.188V
0.463
230.93V
2
0.090A
0.467
59.795%
0.021
5.186V
0.781
230.93V
3
0.550A
2.843
72.378%
0.101
5.167V
3.928
230.93V
4
1.000A
5.150
74.304%
0.167
5.149V
6.931
230.92V
5
1.500A
7.694
75.195%
0.225
5.129V
10.232
230.93V
6
2.501A
12.704
75.319%
0.305
5.080V
16.867
230.92V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.250A
1.980A
1.973A
0.973A
49.705
77.636%
1005
19.1
34.32°C
0.898
12.488V
5.057V
3.342V
5.139V
64.023
37.96°C
115.30V
2
5.525A
2.974A
2.967A
1.171A
99.826
82.911%
1245
24.8
34.70°C
0.949
12.474V
5.047V
3.336V
5.123V
120.401
38.69°C
115.23V
3
9.141A
3.466A
3.454A
1.370A
149.733
84.724%
1400
28.4
35.07°C
0.973
12.441V
5.051V
3.330V
5.110V
176.731
39.48°C
115.16V
4
12.768A
3.964A
3.970A
1.571A
199.742
85.124%
1670
33.4
35.78°C
0.983
12.417V
5.048V
3.323V
5.092V
234.649
40.58°C
115.18V
5
16.058A
4.970A
4.977A
1.774A
249.849
84.887%
1815
35.0
36.13°C
0.987
12.413V
5.033V
3.316V
5.075V
294.331
41.32°C
115.11V
6
19.356A
5.981A
5.981A
1.977A
299.940
84.379%
1847
35.3
36.51°C
0.989
12.406V
5.018V
3.309V
5.061V
355.466
42.34°C
115.03V
7
22.660A
6.999A
6.994A
2.184A
350.056
83.650%
1850
35.4
37.20°C
0.990
12.398V
5.003V
3.302V
5.040V
418.476
44.69°C
114.95V
8
25.967A
8.026A
8.014A
2.392A
400.176
82.716%
1870
35.6
37.81°C
0.990
12.391V
4.986V
3.294V
5.018V
483.795
47.55°C
114.96V
9
29.719A
8.526A
8.518A
2.397A
449.860
81.858%
1850
35.4
38.33°C
0.990
12.360V
4.987V
3.288V
5.009V
549.563
49.48°C
114.88V
10
33.511A
9.024A
9.057A
2.504A
500.192
80.751%
1850
35.4
39.04°C
0.989
12.323V
4.989V
3.280V
4.995V
619.426
53.22°C
114.79V
11
37.708A
8.995A
9.072A
2.507A
549.780
79.751%
1848
35.3
39.39°C
0.989
12.267V
5.005V
3.273V
4.987V
689.368
56.48°C
114.75V
CL1
0.138A
12.002A
12.001A
0.000A
96.683
72.190%
1945
36.3
36.75°C
0.960
13.205V
4.583V
3.321V
5.151V
133.928
42.84°C
115.21V
CL2
40.006A
1.002A
0.998A
1.000A
487.910
81.798%
1805
34.9
39.65°C
0.990
11.854V
5.298V
3.295V
5.081V
596.479
52.97°C
114.83V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.251A
1.979A
1.974A
0.973A
49.714
78.591%
970
18.8
34.11°C
0.685
12.487V
5.057V
3.343V
5.139V
63.257
38.27°C
230.90V
2
5.526A
2.973A
2.967A
1.171A
99.832
84.223%
1260
25.3
34.83°C
0.852
12.474V
5.047V
3.336V
5.123V
118.533
39.45°C
230.87V
3
9.141A
3.466A
3.454A
1.370A
149.729
86.214%
1455
29.3
35.14°C
0.905
12.441V
5.050V
3.330V
5.110V
173.671
40.88°C
230.83V
4
12.767A
3.964A
3.971A
1.571A
199.742
86.794%
1675
33.4
35.64°C
0.937
12.418V
5.047V
3.323V
5.092V
230.133
41.90°C
230.79V
5
16.059A
4.970A
4.973A
1.774A
249.832
86.730%
1810
35.0
36.05°C
0.954
12.412V
5.033V
3.316V
5.075V
288.056
42.64°C
230.75V
6
19.351A
5.981A
5.982A
1.977A
299.908
86.459%
1825
35.1
36.38°C
0.963
12.407V
5.018V
3.310V
5.061V
346.877
43.46°C
230.71V
7
22.656A
6.998A
6.995A
2.183A
350.022
85.993%
1848
35.3
37.27°C
0.970
12.399V
5.003V
3.302V
5.040V
407.034
44.78°C
230.67V
8
25.959A
8.024A
8.012A
2.392A
400.097
85.445%
1860
35.5
38.51°C
0.975
12.392V
4.987V
3.294V
5.019V
468.251
46.29°C
230.72V
9
29.712A
8.523A
8.517A
2.396A
449.793
84.992%
1850
35.4
38.88°C
0.978
12.361V
4.988V
3.288V
5.011V
529.220
47.39°C
230.68V
10
33.493A
9.021A
9.052A
2.502A
500.110
84.438%
1850
35.4
39.57°C
0.980
12.328V
4.989V
3.281V
4.997V
592.282
48.86°C
230.64V
11
37.696A
8.993A
9.070A
2.506A
549.720
83.892%
1848
35.3
41.01°C
0.982
12.269V
5.006V
3.275V
4.990V
655.274
50.66°C
230.59V
CL1
0.141A
12.002A
11.997A
0.000A
96.674
73.439%
1950
36.3
36.67°C
0.870
13.205V
4.581V
3.320V
5.150V
131.638
42.76°C
230.94V
CL2
40.006A
1.002A
1.000A
1.000A
488.152
85.247%
1810
35.0
39.15°C
0.980
11.860V
5.295V
3.295V
5.081V
572.634
48.35°C
230.65V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.163A
0.491A
0.476A
0.193A
19.565
68.161%
845
14.3
0.810
12.439V
5.102V
3.349V
5.177V
28.704
115.35V
2
2.385A
0.983A
0.987A
0.387A
39.986
77.186%
865
14.8
0.896
12.445V
5.090V
3.346V
5.165V
51.805
115.32V
3
3.541A
1.477A
1.464A
0.582A
59.475
80.623%
890
15.3
0.907
12.448V
5.080V
3.343V
5.154V
73.769
115.29V
4
4.762A
1.972A
1.977A
0.778A
79.882
82.293%
1175
23.0
0.931
12.448V
5.072V
3.339V
5.144V
97.070
115.26V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.167A
0.491A
0.477A
0.193A
19.615
69.240%
850
14.4
0.412
12.436V
5.102V
3.349V
5.176V
28.329
230.93V
2
2.388A
0.984A
0.987A
0.387A
40.026
78.197%
865
14.8
0.600
12.444V
5.090V
3.346V
5.165V
51.186
230.91V
3
3.542A
1.477A
1.467A
0.582A
59.497
81.805%
885
15.2
0.748
12.448V
5.080V
3.343V
5.153V
72.730
230.90V
4
4.762A
1.973A
1.977A
0.778A
79.894
83.756%
985
18.9
0.833
12.449V
5.072V
3.340V
5.143V
95.389
230.71V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.8 mV
6.4 mV
19.7 mV
8.1 mV
Pass
20% Load
9.3 mV
7.6 mV
21.4 mV
11.1 mV
Pass
30% Load
13.0 mV
9.9 mV
23.3 mV
13.9 mV
Pass
40% Load
14.4 mV
11.9 mV
25.2 mV
11.3 mV
Pass
50% Load
14.8 mV
13.7 mV
26.9 mV
13.0 mV
Pass
60% Load
18.1 mV
16.0 mV
29.4 mV
17.9 mV
Pass
70% Load
26.8 mV
21.3 mV
32.3 mV
16.4 mV
Pass
80% Load
34.9 mV
25.1 mV
36.0 mV
18.1 mV
Pass
90% Load
39.5 mV
29.0 mV
38.4 mV
19.4 mV
Pass
100% Load
39.4 mV
34.1 mV
41.0 mV
19.4 mV
Pass
110% Load
46.1 mV
39.6 mV
41.7 mV
25.6 mV
Pass
Crossload 1
23.9 mV
86.2 mV
25.6 mV
8.6 mV
Fail
Crossload 2
39.9 mV
34.2 mV
29.7 mV
15.1 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.9 mV
6.4 mV
19.1 mV
7.1 mV
Pass
20% Load
9.7 mV
7.8 mV
20.5 mV
8.9 mV
Pass
30% Load
10.9 mV
9.3 mV
23.3 mV
11.5 mV
Pass
40% Load
12.8 mV
11.7 mV
25.1 mV
9.9 mV
Pass
50% Load
14.2 mV
13.7 mV
27.3 mV
12.3 mV
Pass
60% Load
18.8 mV
16.3 mV
30.0 mV
16.0 mV
Pass
70% Load
22.1 mV
18.7 mV
31.8 mV
13.4 mV
Pass
80% Load
23.6 mV
20.4 mV
34.5 mV
15.7 mV
Pass
90% Load
29.5 mV
23.8 mV
35.5 mV
17.4 mV
Pass
100% Load
33.4 mV
27.4 mV
37.7 mV
17.3 mV
Pass
110% Load
40.6 mV
32.6 mV
38.5 mV
18.9 mV
Pass
Crossload 1
40.0 mV
98.0 mV
25.1 mV
10.1 mV
Fail
Crossload 2
36.3 mV
37.1 mV
27.8 mV
11.7 mV
Pass
The results above are not used in the certification process
Casecom CK-A500 (#2)
Top side
Back side
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted