This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
72.930%
0.037
5.090V
0.314
115.11V
2
0.090A
0.458
76.717%
0.069
5.089V
0.597
115.11V
3
0.550A
2.795
80.132%
0.278
5.081V
3.488
115.11V
4
1.000A
5.074
80.668%
0.358
5.073V
6.290
115.11V
5
1.500A
7.597
79.119%
0.404
5.064V
9.602
115.11V
6
3.000A
15.116
78.204%
0.459
5.038V
19.329
115.10V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
65.057%
0.012
5.090V
0.352
230.26V
2
0.090A
0.458
71.900%
0.022
5.089V
0.637
230.26V
3
0.550A
2.795
78.051%
0.117
5.081V
3.581
230.26V
4
1.000A
5.074
79.830%
0.186
5.074V
6.356
230.26V
5
1.500A
7.598
79.719%
0.244
5.065V
9.531
230.26V
6
3.000A
15.117
79.400%
0.337
5.039V
19.039
230.26V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.160A
1.984A
1.997A
0.988A
59.979
82.585%
618
9.7
36.41°C
0.958
12.144V
5.042V
3.304V
5.063V
72.627
37.88°C
115.10V
2
7.319A
2.978A
2.998A
1.188A
119.712
86.719%
633
10.0
36.95°C
0.969
12.134V
5.038V
3.301V
5.053V
138.046
38.85°C
115.10V
3
11.845A
3.476A
3.485A
1.388A
179.607
87.782%
628
9.9
37.15°C
0.977
12.124V
5.035V
3.299V
5.043V
204.605
39.52°C
115.09V
4
16.380A
3.976A
4.003A
1.590A
239.651
87.871%
633
10.0
37.54°C
0.983
12.115V
5.032V
3.297V
5.033V
272.732
40.20°C
115.09V
5
20.589A
4.973A
5.004A
1.793A
299.746
87.443%
635
10.1
37.74°C
0.987
12.106V
5.028V
3.295V
5.021V
342.790
40.71°C
115.09V
6
24.806A
5.971A
6.013A
1.997A
359.864
86.719%
630
10.0
38.20°C
0.989
12.096V
5.025V
3.293V
5.010V
414.978
41.53°C
115.09V
7
28.998A
6.970A
7.017A
2.201A
419.603
85.689%
820
14.8
38.80°C
0.991
12.087V
5.022V
3.292V
4.998V
489.684
42.59°C
115.08V
8
33.262A
7.971A
8.024A
2.407A
480.104
84.636%
1110
24.7
39.32°C
0.992
12.077V
5.019V
3.289V
4.986V
567.255
43.41°C
115.09V
9
37.876A
8.475A
8.517A
2.411A
539.446
83.613%
1370
31.8
40.00°C
0.993
12.064V
5.016V
3.287V
4.979V
645.173
44.42°C
115.08V
10
42.329A
8.977A
9.040A
3.024A
599.849
82.433%
1806
39.2
40.22°C
0.994
12.052V
5.013V
3.285V
4.961V
727.685
44.89°C
115.08V
11
47.356A
8.983A
9.044A
3.028A
659.885
81.260%
1806
39.2
40.64°C
0.995
12.040V
5.011V
3.284V
4.955V
812.067
45.82°C
115.08V
CL1
0.129A
14.000A
14.000A
0.000A
118.015
80.014%
628
9.9
37.88°C
0.970
12.122V
5.027V
3.291V
5.050V
147.493
40.83°C
115.09V
CL2
48.016A
1.002A
0.997A
1.000A
591.961
83.664%
1520
34.5
40.39°C
0.994
12.051V
5.019V
3.291V
5.010V
707.547
45.52°C
115.07V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.159A
1.983A
1.994A
0.988A
59.937
84.062%
624
9.9
36.47°C
0.834
12.141V
5.041V
3.303V
5.061V
71.301
38.37°C
230.26V
2
7.319A
2.977A
2.997A
1.188A
119.666
88.104%
615
9.7
36.65°C
0.916
12.130V
5.037V
3.300V
5.051V
135.824
38.95°C
230.26V
3
11.845A
3.476A
3.485A
1.389A
179.556
89.255%
628
9.9
37.15°C
0.941
12.120V
5.034V
3.298V
5.041V
201.173
39.77°C
230.26V
4
16.380A
3.976A
4.003A
1.591A
239.590
89.525%
620
9.8
37.53°C
0.959
12.112V
5.030V
3.296V
5.030V
267.624
40.56°C
230.26V
5
20.592A
4.974A
5.008A
1.794A
299.688
89.272%
630
10.0
37.88°C
0.965
12.101V
5.027V
3.294V
5.018V
335.701
41.31°C
230.26V
6
24.822A
5.970A
6.011A
1.998A
359.791
88.808%
614
9.7
38.13°C
0.971
12.086V
5.025V
3.292V
5.007V
405.133
41.76°C
230.27V
7
29.013A
6.971A
7.020A
2.203A
419.546
88.095%
755
14.3
38.47°C
0.977
12.079V
5.021V
3.290V
4.994V
476.243
42.39°C
230.26V
8
33.277A
7.973A
8.029A
2.409A
480.062
87.300%
1075
24.2
38.86°C
0.980
12.070V
5.018V
3.288V
4.982V
549.897
42.97°C
230.26V
9
37.889A
8.475A
8.521A
2.413A
539.410
86.581%
1412
32.7
39.01°C
0.982
12.059V
5.015V
3.286V
4.975V
623.015
43.35°C
230.26V
10
42.349A
8.981A
9.045A
3.027A
599.815
85.714%
1806
39.2
39.44°C
0.984
12.045V
5.012V
3.284V
4.957V
699.783
44.07°C
230.26V
11
47.378A
8.985A
9.049A
3.031A
659.856
84.923%
1806
39.2
40.35°C
0.986
12.034V
5.009V
3.282V
4.950V
777.007
45.48°C
230.26V
CL1
0.136A
14.001A
14.001A
0.000A
118.040
81.071%
640
10.0
37.50°C
0.919
12.130V
5.023V
3.290V
5.047V
145.601
41.47°C
230.27V
CL2
48.008A
1.000A
0.999A
1.000A
592.001
86.669%
1815
39.2
39.62°C
0.983
12.054V
5.017V
3.291V
5.008V
683.061
44.05°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.182A
0.495A
0.480A
0.197A
19.447
69.685%
618
9.7
0.898
12.149V
5.046V
3.307V
5.084V
27.907
115.10V
2
2.439A
0.990A
0.996A
0.394A
39.911
79.472%
626
9.9
0.928
12.146V
5.044V
3.305V
5.078V
50.220
115.10V
3
3.623A
1.487A
1.481A
0.592A
59.388
83.101%
622
9.8
0.957
12.143V
5.043V
3.304V
5.072V
71.465
115.10V
4
4.874A
1.983A
1.998A
0.790A
79.768
85.098%
622
9.8
0.965
12.140V
5.041V
3.303V
5.065V
93.737
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.180A
0.496A
0.482A
0.197A
19.433
71.220%
628
9.9
0.595
12.149V
5.045V
3.306V
5.082V
27.286
230.27V
2
2.438A
0.991A
0.997A
0.394A
39.898
80.749%
624
9.9
0.761
12.144V
5.043V
3.304V
5.076V
49.410
230.27V
3
3.621A
1.485A
1.481A
0.592A
59.340
84.612%
614
9.7
0.832
12.140V
5.042V
3.303V
5.070V
70.132
230.26V
4
4.875A
1.984A
1.995A
0.790A
79.719
86.081%
613
9.6
0.870
12.129V
5.041V
3.302V
5.065V
92.609
230.26V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.5 mV
6.3 mV
13.7 mV
8.3 mV
Pass
20% Load
10.6 mV
6.9 mV
15.7 mV
8.9 mV
Pass
30% Load
12.2 mV
6.6 mV
14.5 mV
9.0 mV
Pass
40% Load
13.5 mV
7.3 mV
15.5 mV
9.6 mV
Pass
50% Load
15.0 mV
7.3 mV
16.9 mV
16.7 mV
Pass
60% Load
18.5 mV
7.8 mV
16.3 mV
13.1 mV
Pass
70% Load
21.6 mV
9.5 mV
17.9 mV
15.0 mV
Pass
80% Load
25.2 mV
9.6 mV
19.8 mV
16.9 mV
Pass
90% Load
30.0 mV
9.2 mV
21.2 mV
17.2 mV
Pass
100% Load
47.1 mV
10.2 mV
22.1 mV
17.8 mV
Pass
110% Load
54.3 mV
11.0 mV
26.0 mV
18.2 mV
Pass
Crossload 1
15.4 mV
9.0 mV
22.0 mV
8.3 mV
Pass
Crossload 2
43.6 mV
9.8 mV
15.0 mV
13.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.3 mV
5.9 mV
11.1 mV
7.6 mV
Pass
20% Load
9.2 mV
6.8 mV
12.3 mV
8.4 mV
Pass
30% Load
11.7 mV
7.3 mV
12.8 mV
9.4 mV
Pass
40% Load
13.0 mV
7.5 mV
13.4 mV
9.5 mV
Pass
50% Load
14.3 mV
7.2 mV
14.3 mV
15.8 mV
Pass
60% Load
16.8 mV
8.4 mV
16.1 mV
13.4 mV
Pass
70% Load
19.3 mV
8.0 mV
19.0 mV
14.2 mV
Pass
80% Load
22.5 mV
8.6 mV
19.1 mV
16.5 mV
Pass
90% Load
25.9 mV
8.6 mV
20.8 mV
17.4 mV
Pass
100% Load
35.9 mV
9.9 mV
23.1 mV
17.4 mV
Pass
110% Load
41.4 mV
11.4 mV
23.8 mV
19.4 mV
Pass
Crossload 1
13.5 mV
8.5 mV
23.1 mV
8.1 mV
Pass
Crossload 2
33.8 mV
9.0 mV
16.8 mV
14.4 mV
Pass
The results above are not used in the certification process
be quiet! System Power U9 600W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted