This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
69.538%
0.040
5.029V
0.325
115.10V
2
0.090A
0.452
75.083%
0.072
5.028V
0.602
115.10V
3
0.550A
2.761
80.566%
0.289
5.019V
3.427
115.10V
4
1.000A
5.011
80.653%
0.375
5.010V
6.213
115.11V
5
1.500A
7.501
80.491%
0.421
5.000V
9.319
115.10V
6
3.000A
14.912
77.140%
0.483
4.970V
19.331
115.09V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.549A
2.004A
1.980A
0.999A
64.767
83.853%
0
<6.0
45.23°C
0.971
12.166V
4.988V
3.329V
5.008V
77.239
39.22°C
115.11V
2
8.094A
3.011A
2.974A
1.200A
129.287
88.113%
0
<6.0
46.23°C
0.976
12.156V
4.983V
3.326V
5.001V
146.728
39.44°C
115.10V
3
13.041A
3.517A
3.457A
1.402A
194.397
89.204%
436
7.6
40.71°C
0.978
12.146V
4.978V
3.324V
4.994V
217.923
48.05°C
115.10V
4
17.997A
4.024A
3.972A
1.605A
259.613
89.474%
436
7.6
40.82°C
0.983
12.136V
4.972V
3.321V
4.986V
290.155
49.23°C
115.10V
5
22.633A
5.036A
4.970A
1.808A
324.922
89.269%
436
7.6
41.60°C
0.987
12.125V
4.965V
3.318V
4.979V
363.980
50.89°C
115.10V
6
27.211A
6.050A
5.973A
2.012A
389.439
88.738%
608
8.9
42.64°C
0.989
12.114V
4.959V
3.315V
4.971V
438.863
52.36°C
115.10V
7
31.863A
7.070A
6.975A
2.217A
454.752
88.119%
1006
19.8
43.38°C
0.990
12.103V
4.952V
3.312V
4.963V
516.065
53.54°C
115.11V
8
36.523A
8.092A
7.980A
2.422A
520.077
87.338%
1431
31.4
44.12°C
0.991
12.093V
4.944V
3.308V
4.955V
595.473
54.70°C
115.16V
9
41.585A
8.608A
8.471A
2.424A
584.978
86.624%
1785
37.1
45.08°C
0.992
12.083V
4.937V
3.306V
4.952V
675.304
56.26°C
115.10V
10
46.398A
9.127A
8.994A
3.039A
649.821
85.780%
1790
37.2
46.71°C
0.993
12.072V
4.931V
3.302V
4.936V
757.546
58.45°C
115.10V
11
51.815A
9.136A
8.997A
3.041A
714.646
84.910%
1790
37.2
47.15°C
0.993
12.061V
4.927V
3.300V
4.933V
841.654
59.71°C
115.09V
CL1
0.138A
12.000A
11.998A
0.000A
101.114
82.959%
435
7.6
43.96°C
0.984
12.152V
4.970V
3.317V
5.015V
121.884
54.14°C
115.10V
CL2
54.005A
1.002A
0.998A
1.000A
665.364
86.336%
1793
37.2
46.76°C
0.993
12.075V
4.951V
3.314V
4.986V
770.670
58.54°C
115.09V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.187A
0.501A
0.477A
0.199A
19.540
69.602%
0
<6.0
0.869
12.173V
4.994V
3.332V
5.027V
28.074
115.13V
2
2.434A
1.002A
0.988A
0.398A
39.914
80.025%
0
<6.0
0.947
12.171V
4.991V
3.331V
5.022V
49.877
115.13V
3
3.614A
1.504A
1.472A
0.598A
59.379
83.851%
0
<6.0
0.971
12.168V
4.989V
3.329V
5.017V
70.815
115.11V
4
4.866A
2.007A
1.979A
0.798A
79.790
85.931%
0
<6.0
0.979
12.165V
4.987V
3.328V
5.012V
92.854
115.11V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.1 mV
12.5 mV
22.6 mV
6.5 mV
Pass
20% Load
8.7 mV
15.2 mV
21.4 mV
8.3 mV
Pass
30% Load
8.2 mV
19.3 mV
26.5 mV
9.9 mV
Pass
40% Load
11.2 mV
30.1 mV
22.9 mV
12.9 mV
Pass
50% Load
11.7 mV
34.5 mV
24.8 mV
17.4 mV
Pass
60% Load
11.6 mV
39.8 mV
26.3 mV
15.5 mV
Pass
70% Load
11.5 mV
17.3 mV
29.0 mV
18.4 mV
Pass
80% Load
13.0 mV
13.9 mV
22.7 mV
20.4 mV
Pass
90% Load
13.9 mV
15.9 mV
23.0 mV
21.3 mV
Pass
100% Load
19.1 mV
17.6 mV
29.9 mV
29.7 mV
Pass
110% Load
25.1 mV
28.3 mV
47.1 mV
43.3 mV
Pass
Crossload 1
12.7 mV
13.7 mV
24.3 mV
9.3 mV
Pass
Crossload 2
20.5 mV
15.5 mV
28.8 mV
21.4 mV
Pass
The results above are not used in the certification process
Corsair Vengeance 650M
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted