This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
58.564%
0.036
5.098V
0.362
115.11V
2
0.087A
0.444
68.519%
0.063
5.097V
0.648
115.11V
3
0.542A
2.758
77.515%
0.272
5.087V
3.558
115.11V
4
1.002A
5.085
76.260%
0.381
5.074V
6.668
115.11V
5
1.502A
7.606
76.251%
0.438
5.065V
9.975
115.11V
6
2.501A
12.610
74.002%
0.496
5.042V
17.040
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
54.780%
0.012
5.098V
0.387
230.31V
2
0.087A
0.445
65.154%
0.020
5.097V
0.683
230.31V
3
0.542A
2.757
76.118%
0.102
5.086V
3.622
230.30V
4
1.002A
5.086
76.666%
0.174
5.075V
6.634
230.30V
5
1.502A
7.606
76.836%
0.235
5.065V
9.899
230.31V
6
2.501A
12.606
77.007%
0.320
5.040V
16.370
230.31V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.383A
1.965A
1.949A
0.986A
74.802
85.576%
758
21.2
40.10°C
0.968
12.141V
5.088V
3.384V
5.065V
87.410
46.01°C
115.13V
2
9.799A
2.947A
2.934A
1.186A
149.730
89.721%
758
21.2
40.87°C
0.986
12.132V
5.077V
3.372V
5.053V
166.884
47.23°C
115.14V
3
15.570A
3.458A
3.446A
1.385A
224.871
91.014%
755
21.3
41.17°C
0.989
12.124V
5.069V
3.363V
5.041V
247.072
48.03°C
115.13V
4
21.337A
3.955A
3.933A
1.590A
299.728
91.199%
753
21.4
41.65°C
0.990
12.116V
5.062V
3.354V
5.030V
328.653
49.03°C
115.13V
5
26.777A
4.951A
4.935A
1.790A
374.685
90.988%
753
21.4
42.20°C
0.990
12.107V
5.054V
3.342V
5.017V
411.797
50.47°C
115.12V
6
32.218A
5.949A
5.941A
1.996A
449.538
90.484%
750
21.4
42.61°C
0.989
12.098V
5.042V
3.330V
5.003V
496.813
52.52°C
115.12V
7
37.676A
6.958A
6.962A
2.200A
524.596
89.144%
935
25.5
43.16°C
0.988
12.090V
5.033V
3.317V
4.991V
588.482
54.89°C
115.19V
8
43.135A
7.967A
7.984A
2.410A
599.516
88.351%
1165
31.7
43.68°C
0.989
12.081V
5.023V
3.305V
4.978V
678.562
55.66°C
115.13V
9
49.035A
8.477A
8.526A
2.411A
674.541
87.564%
1380
36.6
44.89°C
0.991
12.072V
5.015V
3.295V
4.971V
770.340
57.42°C
115.21V
10
54.892A
8.995A
9.039A
2.516A
749.369
86.771%
1467
39.9
46.27°C
0.992
12.063V
5.006V
3.285V
4.962V
863.616
59.21°C
115.17V
11
58.432A
9.011A
9.058A
2.520A
824.240
85.736%
1465
39.9
47.06°C
0.993
12.613V
5.000V
3.279V
4.953V
961.372
60.50°C
115.18V
CL1
0.100A
14.028A
14.006A
0.004A
118.532
83.662%
763
20.8
45.12°C
0.983
12.123V
5.048V
3.319V
5.064V
141.679
55.65°C
115.24V
CL2
61.934A
1.003A
1.002A
1.002A
760.950
87.276%
1470
39.9
46.02°C
0.992
12.070V
5.037V
3.331V
5.006V
871.887
58.07°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.387A
1.963A
1.952A
0.986A
74.817
83.238%
758
21.2
40.08°C
0.834
12.135V
5.087V
3.383V
5.062V
89.883
45.58°C
230.24V
2
9.798A
2.949A
2.934A
1.186A
149.753
89.558%
755
21.3
40.82°C
0.923
12.135V
5.077V
3.372V
5.050V
167.214
46.86°C
230.23V
3
15.571A
3.456A
3.445A
1.386A
224.892
91.472%
755
21.3
41.11°C
0.951
12.126V
5.068V
3.361V
5.039V
245.859
47.67°C
230.24V
4
21.338A
3.952A
3.935A
1.591A
299.768
92.099%
753
21.4
41.81°C
0.963
12.118V
5.061V
3.353V
5.028V
325.486
48.85°C
230.24V
5
26.780A
4.948A
4.937A
1.792A
374.762
92.213%
753
21.4
42.14°C
0.970
12.109V
5.053V
3.341V
5.015V
406.411
49.30°C
230.24V
6
32.223A
5.943A
5.943A
1.998A
449.619
91.963%
768
20.5
42.97°C
0.974
12.099V
5.043V
3.330V
5.001V
488.915
50.58°C
230.24V
7
37.674A
6.959A
6.965A
2.201A
524.648
91.735%
760
21.2
43.17°C
0.977
12.092V
5.031V
3.316V
4.992V
571.914
51.39°C
230.25V
8
43.138A
7.965A
7.987A
2.410A
599.596
91.193%
1110
31.3
43.96°C
0.978
12.082V
5.023V
3.305V
4.978V
657.502
52.48°C
230.24V
9
49.035A
8.476A
8.527A
2.411A
674.623
90.806%
1330
36.3
44.56°C
0.979
12.074V
5.014V
3.294V
4.972V
742.926
53.24°C
230.24V
10
54.892A
8.995A
9.038A
2.516A
749.484
90.330%
1467
39.9
45.55°C
0.980
12.065V
5.007V
3.285V
4.962V
829.715
54.96°C
230.25V
11
61.140A
9.010A
9.057A
2.521A
824.392
89.895%
1467
39.9
46.61°C
0.983
12.057V
5.000V
3.278V
4.954V
917.060
56.62°C
230.25V
CL1
0.098A
14.025A
14.004A
0.005A
118.548
83.311%
766
20.5
43.19°C
0.906
12.121V
5.051V
3.320V
5.066V
142.295
51.95°C
230.25V
CL2
61.944A
1.002A
1.003A
1.002A
761.193
91.010%
1470
39.9
45.38°C
0.980
12.072V
5.037V
3.331V
5.007V
836.383
54.70°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.492A
0.469A
0.196A
19.667
60.070%
760
21.2
0.868
12.141V
5.098V
3.396V
5.088V
32.740
115.14V
2
2.424A
0.981A
0.971A
0.391A
39.720
79.045%
758
21.2
0.930
12.146V
5.095V
3.392V
5.081V
50.250
115.14V
3
3.659A
1.467A
1.475A
0.591A
59.893
83.860%
758
21.2
0.959
12.143V
5.090V
3.387V
5.075V
71.420
115.13V
4
4.875A
1.966A
1.948A
0.786A
79.758
86.422%
758
21.2
0.971
12.140V
5.087V
3.383V
5.069V
92.289
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.204A
0.489A
0.469A
0.196A
19.703
50.722%
758
21.2
0.592
12.144V
5.097V
3.395V
5.086V
38.845
230.24V
2
2.430A
0.980A
0.972A
0.391A
39.776
72.494%
758
21.2
0.707
12.141V
5.093V
3.392V
5.079V
54.868
230.24V
3
3.662A
1.466A
1.474A
0.591A
59.897
81.362%
755
21.3
0.788
12.138V
5.088V
3.386V
5.073V
73.618
230.24V
4
4.878A
1.965A
1.949A
0.786A
79.757
84.399%
758
21.2
0.844
12.134V
5.085V
3.382V
5.068V
94.500
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.0 mV
31.6 mV
13.1 mV
22.6 mV
Pass
20% Load
23.5 mV
34.8 mV
15.3 mV
24.1 mV
Pass
30% Load
25.4 mV
35.8 mV
14.3 mV
23.5 mV
Pass
40% Load
28.3 mV
34.4 mV
14.1 mV
23.9 mV
Pass
50% Load
31.7 mV
34.1 mV
13.0 mV
23.9 mV
Pass
60% Load
37.5 mV
35.4 mV
14.2 mV
34.3 mV
Pass
70% Load
36.6 mV
37.9 mV
22.9 mV
25.6 mV
Pass
80% Load
38.2 mV
39.7 mV
27.1 mV
23.6 mV
Pass
90% Load
41.2 mV
36.6 mV
25.2 mV
25.0 mV
Pass
100% Load
46.8 mV
42.3 mV
23.2 mV
29.5 mV
Pass
110% Load
48.8 mV
41.6 mV
22.1 mV
28.9 mV
Pass
Crossload 1
32.8 mV
32.6 mV
17.3 mV
63.3 mV
Fail
Crossload 2
37.1 mV
39.5 mV
19.2 mV
27.9 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.6 mV
30.2 mV
14.3 mV
22.4 mV
Pass
20% Load
28.9 mV
34.3 mV
14.3 mV
22.5 mV
Pass
30% Load
32.0 mV
45.1 mV
18.7 mV
24.5 mV
Pass
40% Load
31.4 mV
36.6 mV
15.6 mV
27.3 mV
Pass
50% Load
34.1 mV
39.7 mV
17.8 mV
25.8 mV
Pass
60% Load
34.6 mV
37.7 mV
15.1 mV
29.1 mV
Pass
70% Load
38.5 mV
40.7 mV
22.8 mV
27.5 mV
Pass
80% Load
40.7 mV
42.0 mV
26.1 mV
25.3 mV
Pass
90% Load
43.8 mV
41.0 mV
26.8 mV
26.0 mV
Pass
100% Load
46.2 mV
39.6 mV
25.9 mV
28.7 mV
Pass
110% Load
48.7 mV
39.3 mV
22.5 mV
27.5 mV
Pass
Crossload 1
41.3 mV
34.7 mV
16.6 mV
71.6 mV
Fail
Crossload 2
37.7 mV
37.4 mV
20.1 mV
23.7 mV
Pass
The results above are not used in the certification process