This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
57.27%
0.019
5.123V
0.2W
114.87V
2
0.09A
0.461W
75.803%
0.059
5.123V
0.608W
114.87V
3
0.55A
2.812W
80.78%
0.264
5.113V
3.481W
114.87V
4
1A
5.104W
81.018%
0.358
5.103V
6.3W
114.87V
5
1.5A
7.639W
80.457%
0.415
5.092V
9.495W
114.86V
6
3A
15.178W
77.46%
0.485
5.059V
19.595W
114.86V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
60.084%
0.011
5.124V
0.385W
229.94V
2
0.09A
0.461W
67.494%
0.02
5.123V
0.684W
229.95V
3
0.55A
2.812W
78.84%
0.1
5.113V
3.567W
229.94V
4
1A
5.104W
79.613%
0.167
5.103V
6.411W
229.95V
5
1.5A
7.639W
80.071%
0.223
5.092V
9.541W
229.95V
6
3A
15.179W
78.247%
0.335
5.059V
19.399W
229.95V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.236A
1.97A
1.951A
0.981A
84.996
86.754%
746
15.5
40.05°C
0.974
12.106V
5.076V
3.383V
5.095V
97.973
44.43°C
114.86V
20%
11.494A
2.964A
2.939A
1.18A
169.924
89.974%
749
15.7
40.7°C
0.967
12.096V
5.06V
3.368V
5.083V
188.891
47.48°C
114.82V
30%
18.109A
3.466A
3.441A
1.38A
254.924
90.962%
753
15.7
41.15°C
0.987
12.087V
5.049V
3.357V
5.071V
280.243
50.92°C
114.79V
40%
24.741A
3.971A
3.946A
1.581A
340.01
91.135%
763
16
41.65°C
0.995
12.077V
5.037V
3.345V
5.059V
373.076
54.91°C
114.77V
50%
31.025A
4.979A
4.954A
1.783A
424.797
90.644%
991
24
42.21°C
0.998
12.064V
5.022V
3.33V
5.046V
468.624
57.73°C
114.73V
60%
37.291A
5.992A
5.972A
1.987A
509.334
90.158%
1189
26.6
42.89°C
0.999
12.054V
5.007V
3.316V
5.034V
564.91
59.5°C
114.71V
70%
43.631A
7.014A
7.001A
2.191A
594.65
89.484%
1340
33.1
43.04°C
1
12.045V
4.991V
3.3V
5.021V
664.559
61.88°C
114.67V
80%
49.983A
8.042A
8.041A
2.295A
679.475
88.703%
1469
35.4
43.88°C
1
12.035V
4.973V
3.283V
5.01V
765.992
65.21°C
114.64V
90%
56.742A
8.567A
8.56A
2.4A
764.905
87.906%
1559
37.9
44.19°C
1
12.026V
4.961V
3.27V
4.999V
870.195
69.24°C
114.61V
100%
63.249A
9.098A
9.119A
3.014A
849.717
86.914%
1649
39.2
45.75°C
1
12.016V
4.946V
3.256V
4.977V
977.679
74.79°C
114.57V
110%
69.639A
10.15A
10.283A
3.02A
934.311
85.42%
1709
40.6
46.48°C
0.994
12.005V
4.925V
3.238V
4.967V
1093.823
84.21°C
114.56V
CL1
0.116A
12.125A
12.052A
0A
101.289
80.492%
986
24
40.48°C
0.972
12.077V
4.964V
3.294V
5.104V
125.855
59.47°C
114.84V
CL2
0.115A
20.078A
0A
0A
101.363
79.3%
824
18.4
41.2°C
0.969
12.083V
4.979V
3.328V
5.109V
127.788
53.65°C
114.84V
CL3
0.114A
0A
20.059A
0A
67.38
73.101%
757
15.8
40.73°C
0.965
12.084V
4.976V
3.29V
5.106V
92.201
50.74°C
114.85V
CL4
70.602A
0A
0A
0.002A
849.501
88.107%
1597
38.3
45.93°C
1
12.032V
5.03V
3.334V
5.053V
964.169
67.65°C
114.58V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.238A
1.97A
1.951A
0.981A
85.003
87.954%
744
15.4
40.24°C
0.807
12.106V
5.076V
3.383V
5.094V
96.655
43.62°C
229.94V
20%
11.494A
2.964A
2.939A
1.181A
169.94
91.477%
747
15.6
40.86°C
0.895
12.096V
5.061V
3.368V
5.082V
185.773
45.67°C
229.92V
30%
18.111A
3.467A
3.441A
1.381A
254.947
92.572%
750
15.7
41.37°C
0.92
12.086V
5.049V
3.357V
5.071V
275.415
48.44°C
229.91V
40%
24.743A
3.971A
3.946A
1.582A
340.034
92.886%
759
15.9
41.86°C
0.937
12.077V
5.038V
3.345V
5.059V
366.082
51.09°C
229.89V
50%
31.028A
4.979A
4.955A
1.784A
424.851
92.628%
972
23.6
42.32°C
0.949
12.065V
5.022V
3.33V
5.046V
458.666
52.34°C
229.88V
60%
37.294A
5.992A
5.972A
1.987A
509.374
92.394%
1171
26.4
42.73°C
0.957
12.055V
5.007V
3.316V
5.034V
551.317
52.31°C
229.86V
70%
43.631A
7.014A
7.001A
2.191A
594.684
92.014%
1330
32.7
43.22°C
0.963
12.046V
4.991V
3.3V
5.021V
646.325
52.69°C
229.85V
80%
49.983A
8.042A
8.04A
2.296A
679.504
91.564%
1461
35.4
43.96°C
0.969
12.036V
4.973V
3.283V
5.01V
742.066
54.09°C
229.84V
90%
56.741A
8.567A
8.561A
2.401A
764.925
91.143%
1552
37.5
44.31°C
0.975
12.027V
4.96V
3.27V
4.999V
839.238
55.21°C
229.83V
100%
63.246A
9.096A
9.118A
3.014A
849.737
90.611%
1637
38.9
45.52°C
0.98
12.017V
4.947V
3.257V
4.977V
937.818
57.26°C
229.81V
110%
69.637A
10.15A
10.283A
3.02A
934.321
89.971%
1702
40.3
46.42°C
0.985
12.006V
4.926V
3.238V
4.967V
1038.538
59.36°C
229.79V
CL1
0.116A
12.123A
12.05A
0A
101.292
81.9%
962
22.7
40.16°C
0.857
12.078V
4.965V
3.294V
5.104V
123.673
47.74°C
229.94V
CL2
0.115A
20.081A
0A
0A
101.367
80.581%
832
18.7
41.77°C
0.861
12.083V
4.978V
3.328V
5.109V
125.8
47.13°C
229.93V
CL3
0.114A
0A
20.059A
0A
67.382
74.22%
757
15.8
40.92°C
0.797
12.083V
4.976V
3.29V
5.106V
90.788
45.95°C
229.94V
CL4
70.603A
0A
0A
0.002A
849.517
91.684%
1591
38.3
45.55°C
0.98
12.032V
5.03V
3.333V
5.053V
926.604
56.01°C
229.81V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.224A
0.49A
0.485A
0.195A
19.988
68.973%
736
14.6
36.16°C
0.744
12.118V
5.098V
3.401V
5.118V
28.986
38.49°C
114.88V
40W
2.698A
0.687A
0.68A
0.293A
39.99
80.147%
738
14.8
37.92°C
0.806
12.115V
5.095V
3.398V
5.115V
49.893
40.29°C
114.89V
60W
4.172A
0.884A
0.875A
0.391A
59.991
84.063%
740
15.1
38.37°C
0.836
12.112V
5.09V
3.394V
5.111V
71.384
42.56°C
114.91V
80W
5.640A
1.081A
1.07A
0.489A
79.928
86.982%
743
15.3
39.66°C
0.965
12.109V
5.086V
3.39V
5.107V
91.889
43.55°C
114.85V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.226A
0.49A
0.485A
0.195A
19.999
70.192%
734
14.4
36.66°C
0.435
12.117V
5.097V
3.4V
5.118V
28.491
38.06°C
229.94V
40W
2.698A
0.687A
0.68A
0.293A
39.999
82.033%
736
14.6
37.55°C
0.524
12.114V
5.094V
3.397V
5.114V
48.76
39.29°C
229.94V
60W
4.172A
0.884A
0.875A
0.391A
59.999
86.259%
737
14.7
38.96°C
0.579
12.111V
5.09V
3.394V
5.11V
69.576
40.9°C
229.94V
80W
5.642A
1.082A
1.07A
0.49A
79.943
88.203%
740
15.1
39.36°C
0.796
12.109V
5.086V
3.391V
5.106V
90.642
42.06°C
229.94V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.48mV
12.26mV
13.03mV
11.61mV
Pass
20% Load
14.02mV
13.14mV
14.33mV
12.80mV
Pass
30% Load
14.64mV
12.52mV
14.01mV
14.14mV
Pass
40% Load
16.29mV
14.32mV
14.53mV
15.38mV
Pass
50% Load
18.41mV
19.27mV
17.69mV
16.93mV
Pass
60% Load
18.25mV
20.81mV
19.86mV
18.63mV
Pass
70% Load
22.22mV
24.99mV
25.39mV
19.30mV
Pass
80% Load
32.12mV
30.09mV
28.60mV
21.01mV
Pass
90% Load
33.15mV
32.30mV
23.84mV
23.12mV
Pass
100% Load
39.92mV
31.79mV
22.13mV
28.16mV
Pass
110% Load
40.54mV
30.57mV
23.30mV
29.01mV
Pass
Crossload1
19.01mV
13.65mV
14.13mV
13.49mV
Pass
Crossload2
16.60mV
18.13mV
12.51mV
11.20mV
Pass
Crossload3
12.79mV
11.95mV
14.43mV
10.32mV
Pass
Crossload4
38.61mV
25.63mV
20.45mV
25.65mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.30mV
11.90mV
11.84mV
10.84mV
Pass
20% Load
13.82mV
13.70mV
16.13mV
12.90mV
Pass
30% Load
16.03mV
14.79mV
13.96mV
14.55mV
Pass
40% Load
16.96mV
15.56mV
12.93mV
15.12mV
Pass
50% Load
18.31mV
18.49mV
18.98mV
16.05mV
Pass
60% Load
18.10mV
20.92mV
19.80mV
17.45mV
Pass
70% Load
19.75mV
24.32mV
23.84mV
19.56mV
Pass
80% Load
21.96mV
29.26mV
28.28mV
20.75mV
Pass
90% Load
23.92mV
33.38mV
23.94mV
22.35mV
Pass
100% Load
34.15mV
33.59mV
23.71mV
38.41mV
Pass
110% Load
35.36mV
30.68mV
24.04mV
28.72mV
Pass
Crossload1
20.45mV
14.25mV
13.87mV
12.84mV
Pass
Crossload2
15.98mV
18.08mV
12.31mV
12.03mV
Pass
Crossload3
12.68mV
12.21mV
14.48mV
10.84mV
Pass
Crossload4
33.76mV
25.47mV
20.78mV
25.51mV
Pass
The results above are not used in the certification process
Zalman TeraMax II SE 850W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted