This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
70.134%
0.033
5.107V
0.328W
114.83V
2
0.09A
0.46W
75.114%
0.061
5.105V
0.613W
114.85V
3
0.55A
2.801W
79.072%
0.27
5.093V
3.542W
114.84V
4
1A
5.08W
79.312%
0.353
5.08V
6.405W
114.83V
5
1.5A
7.6W
77.22%
0.413
5.066V
9.841W
114.84V
6
3A
15.077W
75.345%
0.48
5.025V
20.01W
114.83V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
59.806%
0.012
5.106V
0.385W
229.83V
2
0.09A
0.46W
68.733%
0.02
5.105V
0.67W
229.83V
3
0.55A
2.801W
77.468%
0.103
5.092V
3.615W
229.82V
4
1A
5.08W
78.679%
0.171
5.079V
6.458W
229.82V
5
1.5A
7.601W
78.564%
0.215
5.067V
9.675W
229.82V
6
3A
15.073W
76.729%
0.315
5.024V
19.419W
229.82V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.626A
1.986A
1.977A
0.987A
64.995
85.557%
834
21.2
40.1°C
0.954
11.966V
5.034V
3.337V
5.068V
75.966
42.36°C
114.82V
20%
8.282A
2.982A
2.969A
1.187A
129.917
89.256%
837
21.2
40.63°C
0.973
11.957V
5.03V
3.334V
5.055V
145.556
43.56°C
114.81V
30%
13.297A
3.481A
3.466A
1.389A
194.913
90.314%
839
21.2
41.23°C
0.979
11.948V
5.027V
3.332V
5.041V
215.819
44.98°C
114.78V
40%
18.325A
3.981A
3.964A
1.592A
259.995
90.463%
845
21.6
41.63°C
0.982
11.939V
5.023V
3.33V
5.025V
287.405
47.1°C
114.76V
50%
23.006A
4.981A
4.96A
1.797A
324.987
90.191%
848
21.9
42.21°C
0.983
11.931V
5.019V
3.327V
5.009V
360.332
48.7°C
114.73V
60%
27.638A
5.982A
5.956A
2A
389.264
89.663%
971
25
42.85°C
0.983
11.921V
5.015V
3.324V
4.994V
434.145
50.06°C
114.7V
70%
32.362A
6.985A
6.955A
2.21A
454.562
88.876%
1367
35.3
43.36°C
0.983
11.910V
5.011V
3.322V
4.978V
511.456
50.11°C
114.68V
80%
37.100A
7.99A
7.955A
2.316A
519.382
88.134%
1770
41.6
43.71°C
0.984
11.900V
5.005V
3.318V
4.966V
589.307
50.59°C
114.66V
90%
42.245A
8.495A
8.443A
2.423A
584.807
87.367%
2188
45.5
44.61°C
0.985
11.890V
5.002V
3.316V
4.953V
669.372
51.46°C
114.63V
100%
47.131A
9.001A
8.962A
3.046A
649.643
86.558%
2189
45.5
45.26°C
0.987
11.881V
4.999V
3.314V
4.925V
750.528
53.01°C
114.61V
110%
51.887A
10.01A
10.057A
3.053A
714.274
85.613%
2192
45.5
46.44°C
0.988
11.871V
4.994V
3.311V
4.914V
834.303
55.83°C
114.59V
CL1
0.116A
12.028A
11.943A
0A
101.286
83.435%
857
22.4
41.34°C
0.971
11.959V
5.005V
3.324V
5.082V
121.396
47.68°C
114.8V
CL2
0.115A
20.005A
0A
0.001A
101.336
81.168%
852
22.1
40.68°C
0.971
11.959V
4.996V
3.33V
5.087V
124.848
43.56°C
114.8V
CL3
0.115A
0A
19.842A
0A
67.379
76.316%
840
21.2
40.21°C
0.959
11.958V
5.032V
3.326V
5.088V
88.289
44.03°C
114.81V
CL4
54.632A
0A
0A
0.003A
649.48
87.732%
2193
45.5
46°C
0.987
11.888V
5.029V
3.327V
5.027V
740.308
52.55°C
114.63V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.627A
1.986A
1.977A
0.987A
65.002
86.423%
836
21.2
40.43°C
0.779
11.967V
5.034V
3.338V
5.068V
75.213
42.72°C
229.81V
20%
8.282A
2.982A
2.969A
1.187A
129.931
90.622%
839
21.2
40.91°C
0.891
11.958V
5.03V
3.335V
5.056V
143.377
43.58°C
229.8V
30%
13.297A
3.481A
3.466A
1.389A
194.931
91.861%
840
21.2
41.47°C
0.928
11.948V
5.026V
3.332V
5.041V
212.202
44.6°C
229.79V
40%
18.328A
3.981A
3.964A
1.592A
260.014
92.244%
842
21.4
41.97°C
0.944
11.939V
5.023V
3.33V
5.025V
281.876
45.83°C
229.78V
50%
23.009A
4.981A
4.96A
1.797A
325.005
92.24%
848
21.9
42.29°C
0.954
11.930V
5.019V
3.327V
5.01V
352.345
47.99°C
229.77V
60%
27.646A
5.982A
5.956A
2A
389.326
91.973%
944
24.8
42.64°C
0.96
11.920V
5.015V
3.324V
4.995V
423.305
48.34°C
229.76V
70%
32.370A
6.985A
6.955A
2.21A
454.626
91.466%
1358
35.5
43.37°C
0.965
11.910V
5.011V
3.322V
4.978V
497.043
48.72°C
229.75V
80%
37.109A
7.99A
7.955A
2.316A
519.44
90.999%
1714
41.1
43.81°C
0.966
11.899V
5.006V
3.318V
4.966V
570.822
48.46°C
229.74V
90%
42.254A
8.495A
8.443A
2.423A
584.863
90.534%
2119
44.5
44.87°C
0.968
11.889V
5.002V
3.316V
4.953V
646.015
49.88°C
229.73V
100%
47.138A
9.001A
8.961A
3.046A
649.697
90.016%
2190
45.5
45.69°C
0.969
11.880V
4.999V
3.314V
4.924V
721.756
51.97°C
229.72V
110%
51.898A
10.009A
10.056A
3.053A
714.317
89.506%
2189
45.5
46.41°C
0.97
11.870V
4.995V
3.311V
4.914V
798.063
53.64°C
229.71V
CL1
0.116A
12.028A
11.943A
0A
101.29
84.534%
857
22.4
41.96°C
0.868
11.959V
5.005V
3.324V
5.083V
119.821
47.31°C
229.81V
CL2
0.116A
20.005A
0A
0.001A
101.339
82.258%
853
22
40.73°C
0.873
11.960V
4.996V
3.33V
5.087V
123.197
44.46°C
229.81V
CL3
0.115A
0A
19.842A
0A
67.381
77.111%
842
21.4
40.94°C
0.812
11.960V
5.032V
3.326V
5.088V
87.38
44.12°C
229.82V
CL4
54.643A
0A
0A
0.003A
649.508
91.178%
2189
45.5
45.01°C
0.97
11.886V
5.029V
3.327V
5.027V
712.359
49.92°C
229.72V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.240A
0.496A
0.494A
0.196A
19.991
72.066%
816
20.6
36.3°C
0.839
11.967V
5.039V
3.34V
5.099V
27.739
37.28°C
114.84V
40W
2.732A
0.695A
0.692A
0.294A
39.994
82%
824
21.3
37.88°C
0.922
11.967V
5.038V
3.34V
5.094V
48.773
39.11°C
114.82V
60W
4.222A
0.893A
0.889A
0.393A
59.994
85.778%
829
21.3
38.61°C
0.947
11.965V
5.038V
3.339V
5.089V
69.942
40.55°C
114.82V
80W
5.708A
1.092A
1.087A
0.492A
79.928
87.711%
831
21.2
39.01°C
0.959
11.964V
5.037V
3.338V
5.083V
91.127
41.25°C
114.82V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.240A
0.496A
0.494A
0.196A
19.998
72.378%
823
21.3
36.03°C
0.479
11.969V
5.039V
3.34V
5.099V
27.631
38.13°C
229.83V
40W
2.732A
0.695A
0.692A
0.294A
39.999
82.586%
825
21.3
37.66°C
0.66
11.968V
5.038V
3.34V
5.094V
48.433
39.47°C
229.82V
60W
4.222A
0.893A
0.889A
0.393A
59.999
86.635%
831
21.2
38.93°C
0.759
11.967V
5.037V
3.339V
5.089V
69.255
40.79°C
229.82V
80W
5.710A
1.092A
1.087A
0.492A
79.94
88.713%
833
21.2
39.42°C
0.818
11.965V
5.037V
3.338V
5.083V
90.11
41.55°C
229.81V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
19.74mV
16.12mV
16.57mV
15.39mV
Pass
20% Load
21.89mV
17.55mV
17.49mV
15.49mV
Pass
30% Load
23.12mV
18.12mV
17.39mV
20.37mV
Pass
40% Load
26.03mV
20.43mV
19.19mV
19.65mV
Pass
50% Load
26.75mV
18.58mV
17.44mV
22.01mV
Pass
60% Load
26.13mV
19.30mV
16.98mV
23.60mV
Pass
70% Load
25.52mV
19.86mV
19.19mV
30.02mV
Pass
80% Load
27.01mV
21.96mV
19.14mV
32.63mV
Pass
90% Load
27.21mV
20.79mV
18.06mV
34.28mV
Pass
100% Load
44.77mV
21.92mV
19.82mV
38.57mV
Pass
110% Load
46.98mV
22.71mV
20.51mV
39.25mV
Pass
Crossload1
36.76mV
18.71mV
19.89mV
14.91mV
Pass
Crossload2
25.11mV
25.10mV
18.21mV
17.70mV
Pass
Crossload3
28.85mV
17.29mV
23.29mV
14.93mV
Pass
Crossload4
40.75mV
23.69mV
18.78mV
31.47mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.82mV
16.42mV
16.16mV
14.73mV
Pass
20% Load
19.79mV
17.81mV
16.37mV
15.24mV
Pass
30% Load
21.74mV
17.40mV
16.68mV
20.22mV
Pass
40% Load
22.66mV
17.45mV
19.39mV
20.47mV
Pass
50% Load
22.66mV
18.53mV
16.72mV
22.63mV
Pass
60% Load
24.60mV
19.20mV
21.19mV
23.24mV
Pass
70% Load
24.85mV
19.50mV
17.96mV
29.15mV
Pass
80% Load
25.47mV
21.35mV
20.16mV
32.33mV
Pass
90% Load
26.75mV
21.40mV
19.39mV
32.79mV
Pass
100% Load
42.29mV
21.90mV
19.08mV
37.93mV
Pass
110% Load
43.02mV
22.75mV
19.56mV
40.19mV
Pass
Crossload1
36.09mV
18.87mV
18.03mV
14.34mV
Pass
Crossload2
23.88mV
23.25mV
16.88mV
17.34mV
Pass
Crossload3
28.69mV
17.09mV
21.96mV
14.57mV
Pass
Crossload4
40.65mV
22.83mV
18.76mV
30.26mV
Pass
The results above are not used in the certification process
Super Flower Combat SG 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted