This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
68.779%
0.033
5.115V
0.335W
114.99V
2
0.09A
0.46W
74.604%
0.06
5.113V
0.616W
114.99V
3
0.55A
2.797W
81.191%
0.261
5.084V
3.445W
114.99V
4
1A
5.056W
81.207%
0.36
5.055V
6.226W
114.99V
5
1.5A
7.532W
80.477%
0.411
5.02V
9.359W
114.99V
6
3A
14.74W
76.344%
0.479
4.913V
19.307W
114.98V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
57.983%
0.012
5.117V
0.397W
230.11V
2
0.09A
0.46W
66.837%
0.02
5.115V
0.688W
230.11V
3
0.55A
2.798W
79.282%
0.099
5.086V
3.529W
230.11V
4
1A
5.059W
80.146%
0.165
5.058V
6.312W
230.11V
5
1.5A
7.539W
79.715%
0.225
5.025V
9.458W
230.11V
6
3A
14.759W
77.412%
0.331
4.919V
19.065W
230.11V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
8.136A
1.975A
1.969A
0.992A
119.999
89.441%
0
<6.0
44.72°C
0.979
12.095V
5.063V
3.352V
5.042V
134.179
40.22°C
114.94V
20%
17.298A
2.965A
2.956A
1.196A
239.96
91.857%
0
<6.0
45.25°C
0.98
12.085V
5.06V
3.349V
5.018V
261.233
40.74°C
114.91V
30%
26.777A
3.461A
3.454A
1.402A
359.316
92.153%
1344
37.3
41.09°C
0.984
12.072V
5.057V
3.344V
4.995V
389.912
45.28°C
114.87V
40%
36.345A
3.958A
3.952A
1.61A
479.687
91.884%
1346
37.3
41.52°C
0.988
12.064V
5.054V
3.34V
4.971V
522.057
46.51°C
114.82V
50%
45.527A
4.951A
4.946A
1.82A
599.473
91.312%
1351
37.3
42.26°C
0.991
12.058V
5.051V
3.336V
4.945V
656.513
49.05°C
114.79V
60%
54.763A
5.944A
5.942A
2.001A
719.856
90.245%
1362
37.4
42.77°C
0.993
12.056V
5.048V
3.332V
4.921V
797.669
51.35°C
114.76V
70%
63.943A
6.94A
6.942A
2.248A
839.768
89.294%
1698
44.6
43.19°C
0.994
12.052V
5.045V
3.328V
4.893V
940.454
52.89°C
114.72V
80%
73.224A
7.935A
7.943A
2.36A
959.774
88.234%
2137
49.4
43.89°C
0.995
12.044V
5.041V
3.323V
4.874V
1087.759
52.82°C
114.67V
90%
82.848A
8.436A
8.435A
2.472A
1079.635
87.145%
2508
56.3
44.99°C
0.996
12.035V
5.038V
3.319V
4.855V
1239
54.95°C
114.63V
100%
92.271A
8.937A
8.96A
3.118A
1199.707
85.858%
2637
56.6
45.83°C
0.996
12.030V
5.036V
3.315V
4.812V
1397.292
57.01°C
114.59V
110%
101.627A
9.936A
10.059A
3.126A
1320.337
84.137%
2611
57.7
46.78°C
0.997
12.024V
5.033V
3.31V
4.799V
1569.4
59.97°C
114.56V
CL1
0.116A
11.922A
11.87A
0A
101.317
81.781%
1356
37.4
42.08°C
0.977
12.111V
5.05V
3.345V
5.089V
123.897
48.3°C
114.94V
CL2
0.116A
19.826A
0A
0A
101.405
80.98%
1386
37.9
40.63°C
0.976
12.099V
5.044V
3.356V
5.098V
125.224
44.79°C
114.93V
CL3
0.116A
0A
19.769A
0A
67.397
75.178%
1352
37.3
40.16°C
0.969
12.097V
5.064V
3.338V
5.096V
89.647
43.35°C
114.94V
CL4
99.903A
0A
0A
0A
1200.201
86.864%
2583
57.7
45.97°C
0.996
12.014V
5.049V
3.324V
5.017V
1381.734
56.26°C
114.58V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
8.134A
1.976A
1.969A
0.992A
120.035
90.588%
0
<6.0
43.89°C
0.878
12.100V
5.064V
3.353V
5.044V
132.508
40.24°C
230.07V
20%
17.306A
2.966A
2.958A
1.195A
240.009
93.146%
1338
37.3
40.54°C
0.946
12.083V
5.059V
3.347V
5.022V
257.667
43.95°C
230.06V
30%
26.792A
3.463A
3.455A
1.4A
359.472
93.82%
1343
37.3
41.15°C
0.964
12.071V
5.056V
3.343V
5V
383.15
45.21°C
230.04V
40%
36.357A
3.959A
3.953A
1.608A
479.827
93.842%
1345
37.3
41.54°C
0.974
12.064V
5.053V
3.34V
4.977V
511.312
45.63°C
230.02V
50%
45.542A
4.952A
4.948A
1.818A
599.59
93.581%
1346
37.3
42.29°C
0.978
12.056V
5.05V
3.336V
4.952V
640.72
45.87°C
230V
60%
54.783A
5.946A
5.944A
2.001A
719.962
92.786%
1355
37.4
42.87°C
0.984
12.053V
5.047V
3.332V
4.929V
775.93
49.52°C
229.98V
70%
63.961A
6.94A
6.943A
2.244A
839.822
92.223%
1561
41.2
43.31°C
0.986
12.050V
5.045V
3.328V
4.903V
910.639
51.14°C
229.98V
80%
73.236A
7.936A
7.945A
2.355A
959.808
91.519%
2085
48.3
43.67°C
0.987
12.042V
5.041V
3.323V
4.884V
1048.747
51.56°C
229.96V
90%
82.859A
8.436A
8.436A
2.466A
1079.622
90.9%
2497
56.3
44.72°C
0.989
12.034V
5.039V
3.319V
4.867V
1187.7
54.03°C
229.93V
100%
92.278A
8.937A
8.96A
3.112A
1199.712
90.132%
2670
56.8
45.46°C
0.99
12.029V
5.036V
3.315V
4.821V
1331.058
54.83°C
229.91V
110%
101.659A
9.937A
10.06A
3.119A
1320.33
89.414%
2672
56.8
46.61°C
0.991
12.021V
5.033V
3.31V
4.809V
1476.655
56.33°C
229.89V
CL1
0.116A
11.923A
11.872A
0A
101.317
83.289%
1357
37.4
41.72°C
0.865
12.108V
5.05V
3.344V
5.091V
121.647
47.48°C
230.08V
CL2
0.116A
19.828A
0A
0A
101.405
82.236%
1361
37.4
39.93°C
0.865
12.097V
5.044V
3.356V
5.1V
123.309
43.88°C
230.07V
CL3
0.116A
0A
19.773A
0A
67.397
76.195%
1342
37.3
39.84°C
0.799
12.095V
5.064V
3.338V
5.097V
88.453
42.81°C
230.07V
CL4
99.915A
0A
0A
0A
1200.19
91.107%
2464
54.8
44.71°C
0.989
12.012V
5.049V
3.324V
5.018V
1317.351
52.74°C
229.9V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.494A
0.492A
0.196A
19.995
71.242%
0
<6.0
42.26°C
0.839
12.088V
5.065V
3.355V
5.105V
28.074
36.04°C
114.99V
40W
2.704A
0.691A
0.689A
0.294A
39.994
80.962%
0
<6.0
45.97°C
0.929
12.087V
5.064V
3.354V
5.097V
49.4
37.37°C
114.99V
60W
4.178A
0.889A
0.885A
0.393A
59.995
84.806%
0
<6.0
44.11°C
0.959
12.092V
5.065V
3.354V
5.088V
70.746
38.64°C
114.98V
80W
5.650A
1.086A
1.082A
0.492A
79.946
87.499%
0
<6.0
42.99°C
0.971
12.093V
5.064V
3.354V
5.079V
91.369
39.76°C
114.97V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.224A
0.494A
0.492A
0.196A
20.009
61.576%
0
<6.0
37.39°C
0.52
12.137V
5.064V
3.354V
5.105V
32.494
36°C
230.08V
40W
2.704A
0.691A
0.689A
0.294A
40.007
81.521%
0
<6.0
43.47°C
0.641
12.093V
5.065V
3.355V
5.097V
49.074
37.41°C
230.08V
60W
4.177A
0.889A
0.885A
0.393A
60.006
86.068%
0
<6.0
44.37°C
0.74
12.097V
5.065V
3.355V
5.088V
69.717
38.75°C
230.08V
80W
5.649A
1.086A
1.082A
0.492A
79.979
88.433%
0
<6.0
43.35°C
0.804
12.099V
5.065V
3.354V
5.08V
90.446
39.13°C
230.08V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.8 mV
6.7 mV
4.0 mV
6.0 mV
Pass
20% Load
14.0 mV
7.7 mV
5.3 mV
8.0 mV
Pass
30% Load
11.9 mV
8.1 mV
5.8 mV
8.2 mV
Pass
40% Load
12.6 mV
7.4 mV
6.0 mV
8.3 mV
Pass
50% Load
13.8 mV
9.5 mV
6.1 mV
9.7 mV
Pass
60% Load
16.6 mV
8.5 mV
7.4 mV
10.6 mV
Pass
70% Load
12.5 mV
7.8 mV
7.6 mV
11.8 mV
Pass
80% Load
13.6 mV
8.3 mV
12.4 mV
12.2 mV
Pass
90% Load
12.3 mV
7.1 mV
11.0 mV
11.7 mV
Pass
100% Load
20.9 mV
9.7 mV
14.1 mV
16.7 mV
Pass
110% Load
22.3 mV
9.2 mV
15.4 mV
17.8 mV
Pass
Crossload 1
20.2 mV
8.8 mV
12.3 mV
8.8 mV
Pass
Crossload 2
12.9 mV
9.1 mV
4.5 mV
7.5 mV
Pass
Crossload 3
12.4 mV
8.0 mV
14.1 mV
8.7 mV
Pass
Crossload 4
19.7 mV
8.9 mV
8.4 mV
15.5 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.9 mV
7.1 mV
4.4 mV
6.7 mV
Pass
20% Load
12.6 mV
7.8 mV
4.9 mV
6.7 mV
Pass
30% Load
11.8 mV
7.7 mV
5.3 mV
7.9 mV
Pass
40% Load
13.3 mV
7.7 mV
5.6 mV
8.6 mV
Pass
50% Load
14.2 mV
8.8 mV
6.0 mV
9.4 mV
Pass
60% Load
17.1 mV
9.4 mV
7.0 mV
10.1 mV
Pass
70% Load
13.8 mV
8.2 mV
6.9 mV
10.7 mV
Pass
80% Load
13.5 mV
9.4 mV
12.6 mV
11.7 mV
Pass
90% Load
14.0 mV
8.2 mV
13.0 mV
12.9 mV
Pass
100% Load
21.5 mV
10.0 mV
14.4 mV
16.5 mV
Pass
110% Load
22.1 mV
9.5 mV
15.0 mV
18.1 mV
Pass
Crossload 1
19.4 mV
12.5 mV
12.2 mV
9.0 mV
Pass
Crossload 2
12.7 mV
9.9 mV
4.3 mV
7.0 mV
Pass
Crossload 3
12.0 mV
7.9 mV
14.3 mV
8.5 mV
Pass
Crossload 4
19.7 mV
9.4 mV
8.3 mV
15.3 mV
Pass
The results above are not used in the certification process
ABKO CM-1200G-M
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted