76.60A (141.59%), 11.575V* *Didn't shut down, Voltage drop (10.921V@77A)
72.60A (134.20%), 11.916V
5V OCP (29.3°C / 44.4°C)
26.5A (147.22%), 4.938V
26.6A (147.78%), 4.936V
3.3V OCP (29.3°C / 44.4°C)
25.7A (142.78%), 3.223V
26.2A (145.56%), 3.219V
5VSB OCP (29.3°C / 44.4°C)
3.9A (130.00%), 4.943V
3.8A (126.67%), 4.935V
OPP (30.84°C / 44.13°C)
136.86%
123.16%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.5
AC Loss to PWR_OK Hold Up Time (ms)
14.2
PWR_OK Inactive to DC Loss Delay (ms)
2.3
Vampire Power
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.90 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.117 W
0.069 W
N/A
0.185 W
N/A
N/A
Apparent Power:
26.370 W
25.254 W
N/A
27.576 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233W
56.043%
0.017
5.167V
0.416W
230.38V
2
0.09A
0.465W
65.834%
0.029
5.164V
0.707W
230.37V
3
0.55A
2.827W
78.681%
0.136
5.139V
3.595W
230.37V
4
1A
5.116W
80.247%
0.208
5.115V
6.376W
230.37V
5
1.5A
7.633W
80.697%
0.258
5.087V
9.457W
230.37V
6
3A
15.003W
79.873%
0.336
5V
18.782W
230.37V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.601A
2.001A
1.989A
0.98A
65.005
83.788%
921
23.3
40.27°C
0.829
12.054V
5V
3.318V
5.101V
77.582
42.01°C
230.38V
20%
8.226A
3.008A
2.997A
1.182A
129.958
88.312%
924
23.4
40.7°C
0.903
12.041V
4.988V
3.304V
5.079V
147.157
43.01°C
230.37V
30%
13.209A
3.516A
3.509A
1.384A
194.965
89.534%
926
23.5
41.25°C
0.934
12.030V
4.979V
3.292V
5.058V
217.755
43.88°C
230.36V
40%
18.209A
4.026A
4.025A
1.589A
260.052
89.732%
1211
30.8
41.83°C
0.95
12.019V
4.969V
3.28V
5.037V
289.808
44.68°C
230.36V
50%
22.866A
5.046A
5.054A
1.795A
325.049
89.307%
1546
39.5
42.09°C
0.961
12.006V
4.956V
3.265V
5.014V
363.968
45.16°C
230.35V
60%
27.492A
6.07A
6.093A
2.001A
389.519
88.811%
1797
42
42.82°C
0.968
11.993V
4.944V
3.25V
4.991V
438.595
46.32°C
230.34V
70%
32.198A
7.1A
7.141A
2.215A
454.843
88.155%
1978
46.2
43.45°C
0.973
11.980V
4.931V
3.235V
4.968V
515.96
47.16°C
230.34V
80%
36.914A
8.133A
8.199A
2.324A
519.639
87.406%
2040
47.2
43.87°C
0.977
11.966V
4.919V
3.22V
4.949V
594.51
48.29°C
230.33V
90%
42.043A
8.659A
8.731A
2.434A
585.064
86.645%
2041
47.2
44.33°C
0.98
11.954V
4.908V
3.207V
4.932V
675.249
49.38°C
230.32V
100%
46.919A
9.189A
9.302A
3.074A
649.897
85.682%
2043
47.3
45.74°C
0.982
11.940V
4.897V
3.193V
4.881V
758.501
51.56°C
230.32V
110%
51.678A
10.236A
10.485A
3.083A
714.535
84.496%
2039
47.2
46.06°C
0.984
11.924V
4.885V
3.175V
4.865V
845.643
53.55°C
230.31V
CL1
0.116A
12.151A
12.186A
0A
101.298
80.553%
1265
32.3
40.2°C
0.886
12.027V
4.954V
3.257V
5.127V
125.756
43.37°C
230.37V
CL2
0.116A
18.127A
0A
0A
91.395
80.234%
940
23.7
40.37°C
0.874
12.040V
4.965V
3.301V
5.142V
113.91
43.53°C
230.37V
CL3
0.116A
0A
18.237A
0A
60.787
74.148%
921
23.3
41.8°C
0.832
12.035V
4.982V
3.257V
5.135V
81.981
44.46°C
230.38V
CL4
54.306A
0A
0A
0A
649.659
86.828%
2060
47.4
45.71°C
0.982
11.963V
4.945V
3.249V
5.085V
748.222
50.79°C
230.31V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.499A
0.495A
0.194A
20.003
68.722%
917
23.2
36.25°C
0.648
12.063V
5.013V
3.334V
5.154V
29.109
37.7°C
230.39V
40W
2.710A
0.699A
0.694A
0.292A
40.001
79.297%
918
23.2
37.06°C
0.762
12.060V
5.01V
3.33V
5.146V
50.444
38.51°C
230.39V
60W
4.191A
0.899A
0.893A
0.389A
60.001
83.947%
919
23.3
38.05°C
0.815
12.057V
5.006V
3.326V
5.138V
71.475
39.65°C
230.38V
80W
5.670A
1.1A
1.093A
0.488A
79.966
86.231%
921
23.3
39.39°C
0.848
12.053V
5.002V
3.321V
5.129V
92.734
41.23°C
230.38V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.2 mV
6.1 mV
7.6 mV
6.2 mV
Pass
20% Load
8.5 mV
6.1 mV
8.7 mV
6.3 mV
Pass
30% Load
8.5 mV
6.5 mV
8.1 mV
6.2 mV
Pass
40% Load
9.5 mV
7.0 mV
8.4 mV
6.4 mV
Pass
50% Load
11.1 mV
7.4 mV
8.9 mV
7.0 mV
Pass
60% Load
14.4 mV
8.1 mV
9.1 mV
6.8 mV
Pass
70% Load
16.0 mV
9.1 mV
10.0 mV
7.2 mV
Pass
80% Load
22.6 mV
11.5 mV
19.1 mV
8.1 mV
Pass
90% Load
27.4 mV
13.4 mV
20.3 mV
8.7 mV
Pass
100% Load
48.2 mV
15.9 mV
23.7 mV
10.8 mV
Pass
110% Load
55.2 mV
17.3 mV
26.9 mV
11.9 mV
Pass
Crossload 1
11.8 mV
9.2 mV
21.3 mV
13.6 mV
Pass
Crossload 2
11.1 mV
9.7 mV
7.3 mV
12.2 mV
Pass
Crossload 3
9.8 mV
7.7 mV
27.1 mV
12.2 mV
Pass
Crossload 4
45.9 mV
11.3 mV
11.4 mV
16.7 mV
Pass
The results above are not used in the certification process
Super Flower Zillion 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted