This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.233W
56.949%
0.018
5.18V
0.41W
230.41V
2
0.09A
0.466W
66.308%
0.03
5.178V
0.704W
230.4V
3
0.55A
2.836W
78.567%
0.138
5.153V
3.61W
230.42V
4
1A
5.131W
80.243%
0.208
5.129V
6.395W
230.42V
5
1.501A
7.655W
80.753%
0.254
5.102V
9.48W
230.42V
6
3.001A
15.051W
79.832%
0.326
5.016V
18.854W
230.42V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.396A
2.014A
1.982A
0.977A
75.01
84.525%
1000
26
40.22°C
0.789
12.149V
4.967V
3.331V
5.119V
88.744
42.5°C
230.41V
20%
9.812A
3.028A
2.984A
1.177A
149.977
89.026%
1002
26.2
40.78°C
0.902
12.134V
4.955V
3.318V
5.098V
168.464
43.55°C
230.4V
30%
15.587A
3.54A
3.493A
1.379A
224.986
90.215%
1012
26.3
41.04°C
0.94
12.120V
4.945V
3.307V
5.078V
249.387
44.36°C
230.39V
40%
21.382A
4.055A
4.006A
1.582A
300.079
90.251%
1458
37.6
41.74°C
0.957
12.106V
4.934V
3.296V
5.057V
332.496
45.34°C
230.38V
50%
26.810A
5.082A
5.028A
1.788A
374.694
89.923%
1768
40.6
42.49°C
0.965
12.092V
4.921V
3.282V
5.035V
416.681
46.32°C
230.37V
60%
32.278A
6.114A
6.059A
1.995A
449.62
89.406%
1963
46
42.64°C
0.973
12.076V
4.908V
3.268V
5.013V
502.899
46.9°C
230.36V
70%
37.758A
7.153A
7.1A
2.205A
524.524
88.776%
2128
46.7
43.21°C
0.976
12.061V
4.895V
3.254V
4.99V
590.843
47.86°C
230.35V
80%
43.324A
8.196A
8.147A
2.313A
599.733
88.05%
2200
46.3
43.94°C
0.979
12.045V
4.881V
3.24V
4.973V
681.128
49.37°C
230.35V
90%
49.241A
8.729A
8.673A
2.421A
674.752
87.327%
2201
46.3
44.55°C
0.982
12.027V
4.869V
3.228V
4.957V
772.675
51.5°C
230.34V
100%
54.986A
9.266A
9.236A
3.057A
749.973
86.423%
2199
46.3
45.32°C
0.985
12.008V
4.857V
3.216V
4.907V
867.799
52.9°C
230.32V
110%
60.620A
10.327A
10.402A
3.065A
825.002
85.361%
2197
46.2
46.16°C
0.987
11.988V
4.842V
3.201V
4.895V
966.489
55.67°C
230.31V
CL1
0.116A
12.249A
12.077A
0A
101.306
80.223%
1565
39.3
41.36°C
0.864
12.116V
4.915V
3.287V
5.154V
126.281
46.15°C
230.39V
CL2
0.115A
18.284A
0A
0A
91.402
79.784%
1040
26.5
40.95°C
0.843
12.136V
4.922V
3.317V
5.165V
114.561
43.41°C
230.39V
CL3
0.115A
0A
18.036A
0A
60.794
73.989%
997
26
40.6°C
0.77
12.133V
4.946V
3.293V
5.159V
82.165
43.77°C
230.4V
CL4
62.276A
0A
0.001A
0A
749.804
87.385%
2222
47.2
45.62°C
0.984
12.040V
4.907V
3.26V
5.105V
858.059
51.77°C
230.35V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.222A
0.502A
0.493A
0.193A
20.009
64.251%
996
26
36.45°C
0.516
12.165V
4.983V
3.345V
5.171V
30.063
38.51°C
230.4V
40W
2.689A
0.703A
0.691A
0.291A
40.007
78.167%
998
26
37.53°C
0.647
12.160V
4.979V
3.342V
5.163V
51.182
39.57°C
230.41V
60W
4.157A
0.905A
0.89A
0.388A
60.007
83.091%
999
26
38.23°C
0.733
12.156V
4.976V
3.338V
5.156V
72.218
40.24°C
230.42V
80W
5.624A
1.107A
1.089A
0.486A
79.982
85.745%
1000
26
39.35°C
0.799
12.152V
4.972V
3.335V
5.148V
93.279
41.61°C
230.42V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.7 mV
6.2 mV
6.8 mV
5.9 mV
Pass
20% Load
11.0 mV
6.5 mV
7.9 mV
6.0 mV
Pass
30% Load
10.4 mV
6.7 mV
8.4 mV
6.3 mV
Pass
40% Load
10.6 mV
7.0 mV
8.9 mV
6.2 mV
Pass
50% Load
13.2 mV
7.7 mV
9.2 mV
7.0 mV
Pass
60% Load
17.3 mV
8.3 mV
11.0 mV
7.1 mV
Pass
70% Load
22.7 mV
9.1 mV
13.0 mV
7.3 mV
Pass
80% Load
30.3 mV
12.9 mV
22.2 mV
8.7 mV
Pass
90% Load
37.3 mV
14.3 mV
25.9 mV
9.2 mV
Pass
100% Load
59.3 mV
16.9 mV
30.5 mV
11.8 mV
Pass
110% Load
66.4 mV
18.6 mV
34.2 mV
12.5 mV
Pass
Crossload 1
13.0 mV
9.0 mV
20.2 mV
15.5 mV
Pass
Crossload 2
13.6 mV
9.6 mV
6.7 mV
14.2 mV
Pass
Crossload 3
10.8 mV
7.9 mV
25.3 mV
13.5 mV
Pass
Crossload 4
56.5 mV
10.7 mV
17.4 mV
17.8 mV
Pass
The results above are not used in the certification process
Super Flower Zillion 750W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted