This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228W
50.909%
0.01
5.067V
0.45W
229.87V
2
0.09A
0.456W
66.976%
0.015
5.066V
0.681W
229.86V
3
0.55A
2.781W
84.729%
0.07
5.055V
3.283W
229.84V
4
1A
5.045W
87.853%
0.119
5.044V
5.743W
229.84V
5
1.5A
7.55W
88.597%
0.169
5.032V
8.521W
229.84V
6
3.001A
14.992W
88.309%
0.285
4.997V
16.977W
229.84V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
14.763A
1.978A
1.96A
0.993A
200.018
91.231%
0
<6.0
43.76°C
0.97
12.085V
5.057V
3.367V
5.037V
219.291
40.24°C
229.8V
20%
30.531A
2.971A
2.946A
1.195A
399.676
93.802%
0
<6.0
45.2°C
0.989
12.079V
5.049V
3.361V
5.021V
426.047
40.86°C
229.77V
30%
46.651A
3.471A
3.443A
1.399A
599.28
94.46%
0
<6.0
44.93°C
0.994
12.073V
5.043V
3.354V
5.006V
634.446
41.23°C
229.73V
40%
62.850A
3.971A
3.943A
1.603A
799.677
94.544%
0
<6.0
49.51°C
0.996
12.068V
5.036V
3.348V
4.991V
845.819
41.96°C
229.7V
50%
78.667A
4.972A
4.939A
1.809A
999.384
94.335%
516
22.2
42.2°C
0.997
12.062V
5.029V
3.341V
4.975V
1059.334
48.17°C
229.67V
60%
94.588A
5.978A
5.941A
2A
1199.864
93.981%
798
22.2
42.95°C
0.998
12.053V
5.019V
3.333V
4.959V
1276.696
47.8°C
229.63V
70%
110.452A
6.986A
6.947A
2.226A
1399.641
93.539%
1113
24.8
43.41°C
0.998
12.046V
5.011V
3.326V
4.943V
1496.338
47.86°C
229.6V
80%
126.405A
7.997A
7.957A
2.333A
1599.642
93.025%
1394
30.3
43.96°C
0.998
12.038V
5.002V
3.318V
4.929V
1719.368
48.17°C
229.57V
90%
142.705A
8.51A
8.457A
2.442A
1799.441
92.472%
1650
37.5
44.5°C
0.998
12.031V
4.994V
3.311V
4.915V
1945.893
48.16°C
229.52V
100%
158.818A
9.024A
8.989A
3.07A
1999.387
91.876%
1850
38.5
45.07°C
0.999
12.024V
4.986V
3.304V
4.887V
2176.192
48.14°C
229.49V
CL1
0.117A
14.348A
14.223A
0A
121.312
84.526%
455
22.2
40.63°C
0.942
12.083V
5.032V
3.353V
5.062V
143.527
47.96°C
229.81V
CL2
0.116A
19.836A
0A
0A
101.35
82.988%
0
<6.0
43.84°C
0.925
12.086V
5.039V
3.362V
5.065V
122.136
40.17°C
229.81V
CL3
0.115A
0A
19.618A
0A
67.387
77.821%
0
<6.0
44.52°C
0.866
12.089V
5.056V
3.364V
5.065V
86.597
40.93°C
229.82V
CL4
166.254A
0A
0A
0A
2000.081
92.057%
1750
38.2
44.78°C
0.999
12.030V
5.011V
3.319V
4.968V
2173.15
47.82°C
229.48V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.230A
0.494A
0.489A
0.197A
20.005
57.703%
0
<6.0
41.64°C
0.59
12.086V
5.061V
3.373V
5.065V
34.687
36.32°C
229.83V
40W
2.704A
0.691A
0.685A
0.296A
40.003
72.2%
0
<6.0
42.23°C
0.755
12.087V
5.062V
3.373V
5.062V
55.402
37.34°C
229.83V
60W
4.180A
0.889A
0.88A
0.395A
60.002
79.663%
0
<6.0
41.41°C
0.839
12.087V
5.062V
3.373V
5.058V
75.315
38.19°C
229.81V
80W
5.652A
1.086A
1.076A
0.495A
79.945
83.551%
0
<6.0
45°C
0.885
12.088V
5.062V
3.372V
5.055V
95.693
39.58°C
229.81V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.6 mV
16.6 mV
15.2 mV
8.7 mV
Pass
20% Load
19.0 mV
16.9 mV
18.6 mV
9.7 mV
Pass
30% Load
20.9 mV
17.5 mV
17.0 mV
10.7 mV
Pass
40% Load
21.8 mV
18.0 mV
16.9 mV
10.2 mV
Pass
50% Load
20.7 mV
17.9 mV
17.3 mV
10.0 mV
Pass
60% Load
22.7 mV
18.6 mV
18.5 mV
10.5 mV
Pass
70% Load
22.9 mV
20.2 mV
18.7 mV
11.7 mV
Pass
80% Load
24.9 mV
20.3 mV
19.4 mV
11.7 mV
Pass
90% Load
28.6 mV
20.7 mV
20.3 mV
13.8 mV
Pass
100% Load
45.6 mV
24.5 mV
22.8 mV
17.9 mV
Pass
Crossload 1
22.3 mV
20.6 mV
18.3 mV
25.8 mV
Pass
Crossload 2
22.4 mV
23.8 mV
18.0 mV
21.3 mV
Pass
Crossload 3
19.3 mV
17.1 mV
19.5 mV
21.1 mV
Pass
Crossload 4
45.2 mV
22.0 mV
19.3 mV
37.6 mV
Pass
The results above are not used in the certification process
Cooler Master X MIGHTY Platinum 2000 230V
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case