This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
50.786%
0.026
5.134V
0.455W
230.41V
2
0.09A
0.462W
61.337%
0.043
5.132V
0.753W
230.4V
3
0.55A
2.812W
75.015%
0.179
5.112V
3.749W
230.4V
4
1A
5.091W
75.143%
0.258
5.09V
6.776W
230.4V
5
1.5A
7.602W
76.144%
0.302
5.067V
9.983W
230.4V
6
2.501A
12.553W
75.895%
0.353
5.02V
16.537W
230.4V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.082A
1.963A
1.969A
0.985A
60.015
78.146%
933
25.6
34.26°C
0.9
12.462V
5.096V
3.353V
5.078V
76.803
40.02°C
230.41V
20%
7.163A
2.954A
2.966A
1.187A
119.98
84.379%
936
25.7
34.88°C
0.964
12.436V
5.079V
3.338V
5.058V
142.192
41.69°C
230.41V
30%
11.585A
3.454A
3.471A
1.389A
180.02
86.371%
942
25.9
35.08°C
0.983
12.426V
5.068V
3.328V
5.04V
208.43
43.89°C
230.4V
40%
16.025A
3.957A
3.98A
1.594A
240.064
86.915%
953
26
35.62°C
0.988
12.409V
5.057V
3.317V
5.021V
276.202
46.25°C
230.4V
50%
20.135A
4.963A
4.998A
1.8A
300.023
86.95%
973
26.8
36.12°C
0.991
12.391V
5.039V
3.302V
5.001V
345.049
49.27°C
230.39V
60%
24.263A
5.976A
6.025A
2.001A
360.022
86.609%
996
27.6
36.97°C
0.993
12.374V
5.022V
3.287V
4.98V
415.687
52.9°C
230.38V
70%
28.374A
6.998A
7.064A
2.219A
419.731
85.979%
1203
33
37.38°C
0.992
12.356V
5.003V
3.271V
4.958V
488.18
56.08°C
230.36V
80%
32.569A
8.026A
8.111A
2.328A
479.725
85.238%
1495
39.3
37.82°C
0.992
12.337V
4.985V
3.255V
4.94V
562.807
57.18°C
230.34V
90%
37.109A
8.548A
8.633A
2.437A
539.555
84.456%
1779
44.3
38.29°C
0.992
12.316V
4.973V
3.243V
4.926V
638.863
58.8°C
230.33V
100%
41.726A
9.073A
9.19A
2.546A
600.248
83.56%
1781
44.5
39.84°C
0.992
12.295V
4.96V
3.232V
4.911V
718.344
62.91°C
230.33V
110%
45.970A
10.121A
10.357A
2.553A
660.097
82.306%
1782
44.5
40.64°C
0.992
12.275V
4.941V
3.215V
4.897V
802.011
68.3°C
230.31V
CL1
0.112A
10.859A
10.891A
0.001A
91.311
78.074%
965
26.3
36.76°C
0.955
12.459V
4.992V
3.278V
5.079V
116.956
52.21°C
230.39V
CL2
0.113A
18.028A
0A
0.001A
91.425
77.412%
942
25.9
36.4°C
0.956
12.463V
4.992V
3.313V
5.097V
118.104
47.93°C
230.4V
CL3
0.112A
0A
18.098A
0.001A
60.808
71.585%
935
25.7
37.18°C
0.917
12.461V
5.041V
3.282V
5.084V
84.951
46.1°C
230.41V
CL4
48.792A
0A
0.001A
0.002A
600.218
84.457%
1778
44.3
39.87°C
0.992
12.301V
5.075V
3.321V
5.08V
710.68
60.73°C
230.33V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.191A
0.489A
0.489A
0.195A
20.006
62.204%
884
23.5
30.45°C
0.741
12.473V
5.118V
3.371V
5.125V
32.158
35.1°C
230.4V
40W
2.622A
0.684A
0.686A
0.293A
40.004
74.042%
899
24
31.96°C
0.835
12.467V
5.114V
3.367V
5.118V
54.029
36.48°C
230.39V
60W
4.054A
0.881A
0.883A
0.391A
60.002
78.933%
913
24.5
32.07°C
0.898
12.462V
5.11V
3.364V
5.11V
76.019
37.56°C
230.39V
80W
5.486A
1.078A
1.08A
0.49A
79.968
81.921%
922
25.1
33.37°C
0.932
12.456V
5.106V
3.36V
5.103V
97.615
38.89°C
230.39V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.3 mV
12.1 mV
12.7 mV
37.9 mV
Pass
20% Load
19.2 mV
13.3 mV
13.7 mV
38.2 mV
Pass
30% Load
21.9 mV
13.1 mV
15.4 mV
37.6 mV
Pass
40% Load
23.5 mV
13.3 mV
16.6 mV
36.5 mV
Pass
50% Load
25.5 mV
14.7 mV
18.2 mV
35.4 mV
Pass
60% Load
28.9 mV
15.1 mV
19.3 mV
35.2 mV
Pass
70% Load
31.2 mV
16.1 mV
21.7 mV
34.3 mV
Pass
80% Load
35.8 mV
19.1 mV
29.0 mV
36.5 mV
Pass
90% Load
35.5 mV
20.3 mV
29.9 mV
38.1 mV
Pass
100% Load
49.0 mV
22.9 mV
35.8 mV
42.0 mV
Pass
110% Load
53.2 mV
24.8 mV
38.9 mV
42.6 mV
Pass
Crossload 1
25.8 mV
17.4 mV
25.4 mV
61.6 mV
Fail
Crossload 2
33.5 mV
24.5 mV
13.6 mV
56.7 mV
Fail
Crossload 3
32.8 mV
11.8 mV
33.1 mV
60.5 mV
Fail
Crossload 4
46.5 mV
18.1 mV
25.4 mV
68.4 mV
Fail
The results above are not used in the certification process
ABKO CM-600B
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case