This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
230V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
56.481%
0.012
5.131V
0.41W
229.93V
2
0.09A
0.462W
66.385%
0.021
5.131V
0.696W
229.94V
3
0.55A
2.811W
77.597%
0.102
5.11V
3.623W
229.94V
4
1A
5.09W
79.047%
0.169
5.09V
6.441W
229.93V
5
1.5A
7.601W
79.202%
0.214
5.067V
9.599W
229.94V
6
3A
14.996W
77.089%
0.324
4.998V
19.452W
229.94V
Supplementary Tests (For Reference)
230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
12.315A
1.985A
1.981A
0.982A
169.998
87.843%
1280
37.3
40.07°C
0.9
12.050V
5.04V
3.332V
5.09V
193.528
44.78°C
229.91V
20%
25.662A
2.979A
2.975A
1.182A
339.966
91.778%
1377
39
40.67°C
0.946
12.043V
5.037V
3.328V
5.075V
370.425
45.73°C
229.89V
30%
39.333A
3.476A
3.474A
1.384A
509.614
92.875%
1416
39.3
41.32°C
0.964
12.040V
5.035V
3.324V
5.06V
548.707
47.71°C
229.86V
40%
53.071A
3.975A
3.975A
1.587A
679.612
93.115%
1523
42.6
41.56°C
0.972
12.029V
5.033V
3.321V
5.043V
729.865
49.08°C
229.84V
50%
66.500A
4.971A
4.975A
1.791A
849.744
92.981%
1668
47.9
42.28°C
0.978
12.019V
5.03V
3.317V
5.026V
913.889
51.07°C
229.81V
60%
79.953A
5.969A
5.978A
1.996A
1019.821
92.632%
1813
47.7
42.73°C
0.982
12.007V
5.027V
3.313V
5.01V
1100.949
52.86°C
229.78V
70%
93.433A
6.967A
6.983A
2.203A
1189.976
92.169%
1975
52.5
43.29°C
0.985
11.996V
5.025V
3.309V
4.994V
1291.085
55.02°C
229.75V
80%
106.942A
7.965A
7.989A
2.309A
1359.586
91.688%
2106
51.6
43.71°C
0.987
11.985V
5.022V
3.304V
4.981V
1482.842
56.97°C
229.72V
90%
120.873A
8.465A
8.483A
2.416A
1529.764
91.132%
2281
53.9
44.63°C
0.989
11.973V
5.02V
3.301V
4.968V
1678.618
59.84°C
229.69V
100%
134.569A
8.967A
9.008A
3.037A
1699.383
90.459%
2422
59.1
45.47°C
0.99
11.961V
5.019V
3.297V
4.94V
1878.624
62.23°C
229.66V
110%
148.233A
9.968A
10.112A
3.044A
1869.56
89.72%
2528
62.1
46.7°C
0.992
11.949V
5.016V
3.293V
4.929V
2083.769
66.46°C
229.63V
CL1
0.117A
15.577A
15.53A
0A
131.309
79.409%
1605
44.8
40.85°C
0.884
12.040V
5.027V
3.322V
5.107V
165.362
50.59°C
229.92V
CL2
0.115A
24.867A
0A
0A
126.245
78.084%
1484
41.7
40.71°C
0.883
12.045V
5.021V
3.337V
5.114V
161.68
47.69°C
229.93V
CL3
0.115A
0A
24.87A
0A
83.886
71.38%
1328
38
40.18°C
0.84
12.046V
5.045V
3.317V
5.111V
117.519
46.35°C
229.95V
CL4
142.000A
0A
0A
0A
1699.932
91.092%
2313
54.1
45.78°C
0.99
11.971V
5.029V
3.305V
5.034V
1866.196
60.3°C
229.67V
The results above are not used in the certification process
230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.227A
0.496A
0.495A
0.195A
19.999
61.559%
1195
34.8
36.48°C
0.561
12.100V
5.041V
3.335V
5.122V
32.495
39.1°C
229.94V
40W
2.706A
0.694A
0.693A
0.293A
39.999
66.658%
1197
34.8
37.8°C
0.719
12.077V
5.041V
3.335V
5.115V
60.006
41.42°C
229.93V
60W
4.187A
0.893A
0.891A
0.391A
59.998
72.794%
1199
34.8
38.75°C
0.783
12.068V
5.041V
3.335V
5.11V
82.422
43.03°C
229.92V
80W
5.665A
1.091A
1.088A
0.489A
79.942
81.163%
1200
34.8
39.41°C
0.813
12.061V
5.041V
3.334V
5.11V
98.493
43.29°C
229.92V
The results above are not used in the certification process
230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
21.7 mV
10.3 mV
11.2 mV
10.8 mV
Pass
20% Load
30.2 mV
10.7 mV
11.1 mV
10.5 mV
Pass
30% Load
17.0 mV
11.3 mV
11.5 mV
15.0 mV
Pass
40% Load
16.9 mV
11.8 mV
13.1 mV
13.9 mV
Pass
50% Load
16.9 mV
11.9 mV
13.3 mV
16.4 mV
Pass
60% Load
17.9 mV
13.4 mV
13.3 mV
17.9 mV
Pass
70% Load
19.2 mV
14.1 mV
13.8 mV
20.7 mV
Pass
80% Load
19.9 mV
14.6 mV
14.9 mV
19.5 mV
Pass
90% Load
22.3 mV
16.6 mV
15.7 mV
22.5 mV
Pass
100% Load
32.4 mV
19.3 mV
18.0 mV
21.0 mV
Pass
110% Load
34.7 mV
21.5 mV
19.6 mV
22.9 mV
Pass
Crossload 1
22.6 mV
12.9 mV
14.6 mV
7.5 mV
Pass
Crossload 2
17.4 mV
19.2 mV
11.9 mV
6.9 mV
Pass
Crossload 3
12.3 mV
12.6 mV
16.1 mV
6.8 mV
Pass
Crossload 4
30.9 mV
18.0 mV
16.6 mV
14.0 mV
Pass
The results above are not used in the certification process