This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
69.549%
0.033
5.109V
0.331W
115.14V
2
0.09A
0.46W
75.294%
0.06
5.107V
0.613W
115.15V
3
0.55A
2.801W
79.634%
0.267
5.092V
3.517W
115.15V
4
1A
5.077W
79.53%
0.364
5.076V
6.384W
115.15V
5
1.5A
7.59W
77.509%
0.415
5.059V
9.793W
115.15V
6
3A
15.019W
75.771%
0.48
5.006V
19.822W
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
58.667%
0.012
5.108V
0.392W
230.38V
2
0.09A
0.46W
68.299%
0.02
5.107V
0.674W
230.38V
3
0.55A
2.801W
78.073%
0.102
5.091V
3.588W
230.39V
4
1A
5.076W
79.231%
0.169
5.075V
6.405W
230.39V
5
1.5A
7.591W
78.739%
0.23
5.06V
9.64W
230.38V
6
3A
15.013W
78.086%
0.332
5.004V
19.227W
230.38V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.256A
1.98A
1.966A
0.988A
85.006
87.774%
1082
26.1
40.1°C
0.957
12.064V
5.052V
3.357V
5.061V
96.85
44.35°C
115.15V
20%
11.535A
2.972A
2.952A
1.19A
169.975
90.592%
1090
26.5
40.59°C
0.978
12.056V
5.049V
3.354V
5.044V
187.63
45.11°C
115.12V
30%
18.168A
3.467A
3.445A
1.394A
255.01
91.355%
1100
26.7
41.1°C
0.981
12.051V
5.05V
3.353V
5.021V
279.144
46.21°C
115.1V
40%
24.813A
3.965A
3.942A
1.599A
340.08
91.261%
1098
26.6
41.75°C
0.981
12.045V
5.045V
3.349V
5.004V
372.646
47.28°C
115.07V
50%
31.113A
4.959A
4.932A
1.806A
425.046
90.859%
1101
26.7
42.27°C
0.98
12.038V
5.042V
3.346V
4.984V
467.802
48.33°C
115.05V
60%
37.382A
5.953A
5.922A
2.001A
509.493
90.291%
1105
26.7
42.77°C
0.981
12.031V
5.041V
3.344V
4.963V
564.278
49.32°C
115.02V
70%
43.727A
6.948A
6.914A
2.227A
594.91
89.436%
1522
36.5
43.17°C
0.983
12.024V
5.039V
3.342V
4.94V
665.176
50.24°C
114.99V
80%
50.081A
7.946A
7.91A
2.336A
679.696
88.63%
1904
42.5
43.63°C
0.985
12.017V
5.034V
3.337V
4.924V
766.894
51.7°C
114.96V
90%
56.836A
8.446A
8.395A
2.446A
765.146
87.712%
2237
46.0
44.5°C
0.986
12.011V
5.032V
3.335V
4.907V
872.345
53.71°C
114.93V
100%
63.332A
8.944A
8.911A
3.083A
849.978
86.628%
2239
46.0
45.82°C
0.987
12.005V
5.031V
3.333V
4.867V
981.175
55.84°C
114.9V
110%
69.707A
9.943A
9.999A
3.093A
934.57
85.522%
2239
46.0
46.79°C
0.988
11.997V
5.029V
3.33V
4.85V
1092.785
57.72°C
114.88V
CL1
0.116A
13.142A
13.034A
0A
111.299
83.857%
1113
26.7
41.02°C
0.974
12.055V
5.037V
3.352V
5.075V
132.728
46.45°C
115.14V
CL2
0.116A
19.877A
0.001A
0.001A
101.4
82.114%
1114
26.7
40.45°C
0.974
12.060V
5.031V
3.365V
5.086V
123.487
47.46°C
115.14V
CL3
0.116A
0A
19.693A
0A
67.396
76.587%
1095
26.6
40.01°C
0.958
12.057V
5.066V
3.351V
5.083V
88.019
49.11°C
115.15V
CL4
70.735A
0.001A
0A
0A
849.683
87.617%
2243
46.1
45.12°C
0.988
12.013V
5.054V
3.344V
4.998V
969.78
56.09°C
114.91V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
5.254A
1.979A
1.965A
0.988A
85
88.514%
1096
26.6
40.42°C
0.808
12.066V
5.055V
3.358V
5.06V
96.03
44.68°C
230.37V
20%
11.531A
2.97A
2.951A
1.19A
169.958
91.869%
1098
26.6
40.8°C
0.905
12.059V
5.051V
3.355V
5.043V
184.996
45.33°C
230.36V
30%
18.162A
3.467A
3.446A
1.394A
254.967
92.754%
1096
26.6
41.29°C
0.934
12.053V
5.049V
3.352V
5.024V
274.882
46.36°C
230.36V
40%
24.808A
3.964A
3.941A
1.599A
340.057
92.949%
1102
26.7
41.7°C
0.949
12.046V
5.047V
3.35V
5.004V
365.856
47.24°C
230.35V
50%
31.106A
4.957A
4.93A
1.806A
425.02
92.854%
1106
26.7
42.15°C
0.957
12.039V
5.045V
3.347V
4.983V
457.709
48.23°C
230.34V
60%
37.375A
5.951A
5.92A
2.001A
509.484
92.529%
1110
26.7
42.67°C
0.961
12.033V
5.043V
3.345V
4.963V
550.622
49.26°C
230.33V
70%
43.722A
6.947A
6.913A
2.227A
594.889
91.979%
1612
37.6
43.29°C
0.964
12.025V
5.04V
3.342V
4.941V
646.772
50.38°C
230.32V
80%
50.074A
7.944A
7.908A
2.336A
679.725
91.439%
1990
43.8
43.78°C
0.966
12.018V
5.035V
3.338V
4.924V
743.367
51.79°C
230.31V
90%
56.831A
8.445A
8.394A
2.446A
765.163
90.884%
2241
46.1
44.89°C
0.968
12.012V
5.033V
3.335V
4.906V
841.913
53.91°C
230.3V
100%
63.328A
8.943A
8.909A
3.083A
849.991
90.207%
2240
46.0
45.69°C
0.97
12.005V
5.032V
3.333V
4.866V
942.271
55.73°C
230.29V
110%
69.701A
9.943A
9.998A
3.093A
934.572
89.56%
2242
46.1
46.87°C
0.972
11.998V
5.029V
3.33V
4.851V
1043.511
57.78°C
230.28V
CL1
0.116A
13.139A
13.031A
0A
111.299
84.755%
1115
26.7
40.76°C
0.866
12.056V
5.038V
3.353V
5.076V
131.315
46.21°C
230.39V
CL2
0.116A
19.871A
0.001A
0.001A
101.402
82.863%
1117
26.8
40.19°C
0.854
12.061V
5.032V
3.365V
5.087V
122.358
47.22°C
230.38V
CL3
0.116A
0A
19.698A
0A
67.397
77.388%
1101
26.7
40.39°C
0.785
12.056V
5.068V
3.35V
5.083V
87.09
49.45°C
230.39V
CL4
70.740A
0.001A
0A
0A
849.724
91.17%
2244
46.1
45.32°C
0.971
12.012V
5.052V
3.343V
4.997V
932.017
56.3°C
230.3V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.495A
0.491A
0.196A
20.011
72.322%
1069
25.8
36.56°C
0.813
12.055V
5.054V
3.359V
5.099V
27.668
39.64°C
115.17V
40W
2.712A
0.693A
0.688A
0.295A
40.007
82.318%
1073
26
37.24°C
0.914
12.054V
5.054V
3.358V
5.093V
48.599
40.57°C
115.17V
60W
4.192A
0.891A
0.885A
0.393A
60.004
86.112%
1075
26
38.08°C
0.943
12.055V
5.054V
3.358V
5.087V
69.681
41.89°C
115.16V
80W
5.664A
1.089A
1.081A
0.492A
79.973
87.898%
1080
26.1
39.59°C
0.957
12.064V
5.054V
3.357V
5.08V
90.984
43.54°C
115.15V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.495A
0.491A
0.196A
20.003
71.648%
1083
26.1
36.88°C
0.461
12.057V
5.056V
3.36V
5.099V
27.918
39.93°C
230.41V
40W
2.712A
0.692A
0.688A
0.295A
40.001
82.375%
1083
26.1
37.18°C
0.628
12.056V
5.055V
3.359V
5.093V
48.562
40.55°C
230.41V
60W
4.191A
0.89A
0.884A
0.393A
60
86.656%
1086
26.2
38.55°C
0.734
12.056V
5.055V
3.358V
5.087V
69.241
42.11°C
230.4V
80W
5.664A
1.088A
1.081A
0.492A
79.964
88.687%
1087
26.2
39.03°C
0.794
12.064V
5.054V
3.358V
5.08V
90.166
42.89°C
230.4V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
24.29mV
10.66mV
9.77mV
10.24mV
Pass
20% Load
24.34mV
11.94mV
11.44mV
10.85mV
Pass
30% Load
25.85mV
13.01mV
14.60mV
13.04mV
Pass
40% Load
24.83mV
13.82mV
13.83mV
15.08mV
Pass
50% Load
25.64mV
16.02mV
14.50mV
18.44mV
Pass
60% Load
26.61mV
17.19mV
13.83mV
19.97mV
Pass
70% Load
29.92mV
24.74mV
15.00mV
23.74mV
Pass
80% Load
33.02mV
27.34mV
20.80mV
25.53mV
Pass
90% Load
34.60mV
29.94mV
26.24mV
22.32mV
Pass
100% Load
48.23mV
26.59mV
30.48mV
24.62mV
Pass
110% Load
52.05mV
34.91mV
32.93mV
29.92mV
Pass
Crossload1
50.94mV
26.35mV
21.44mV
12.62mV
Pass
Crossload2
35.06mV
29.43mV
16.73mV
14.67mV
Pass
Crossload3
33.28mV
18.16mV
25.03mV
8.20mV
Pass
Crossload4
40.06mV
20.99mV
25.13mV
14.19mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
27.85mV
11.02mV
10.07mV
11.46mV
Pass
20% Load
25.10mV
11.89mV
11.19mV
10.90mV
Pass
30% Load
25.34mV
13.98mV
16.48mV
14.72mV
Pass
40% Load
24.68mV
14.23mV
14.04mV
15.34mV
Pass
50% Load
23.61mV
14.64mV
13.48mV
15.28mV
Pass
60% Load
26.26mV
17.29mV
14.04mV
21.09mV
Pass
70% Load
29.56mV
25.35mV
15.77mV
25.98mV
Pass
80% Load
31.80mV
28.36mV
20.91mV
25.68mV
Pass
90% Load
33.43mV
28.77mV
25.99mV
24.71mV
Pass
100% Load
48.31mV
33.40mV
31.10mV
28.18mV
Pass
110% Load
51.36mV
28.40mV
33.63mV
28.30mV
Pass
Crossload1
50.67mV
26.00mV
21.69mV
12.70mV
Pass
Crossload2
29.61mV
28.92mV
16.07mV
13.91mV
Pass
Crossload3
38.32mV
19.89mV
28.38mV
9.42mV
Pass
Crossload4
40.18mV
20.60mV
24.64mV
13.91mV
Pass
The results above are not used in the certification process
Gamer Storm PN850D
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted