This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
65.538%
0.035
5.121V
0.325
115.07V
2
0.087A
0.447
73.520%
0.064
5.119V
0.608
115.07V
3
0.542A
2.764
80.771%
0.271
5.097V
3.422
115.04V
4
1.002A
5.087
80.990%
0.365
5.076V
6.281
115.05V
5
1.502A
7.589
80.975%
0.417
5.054V
9.372
115.05V
6
3.001A
14.995
79.901%
0.486
4.996V
18.767
115.05V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
58.953%
0.012
5.121V
0.363
230.22V
2
0.087A
0.447
68.769%
0.021
5.119V
0.650
230.21V
3
0.542A
2.763
78.740%
0.106
5.096V
3.509
230.22V
4
1.002A
5.081
80.180%
0.176
5.071V
6.337
230.21V
5
1.502A
7.578
80.806%
0.234
5.046V
9.378
230.21V
6
3.002A
14.921
80.195%
0.337
4.971V
18.606
230.21V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.398A
1.974A
1.985A
0.986A
99.794
89.208%
0
<6.0
42.03°C
0.982
12.226V
5.058V
3.323V
5.062V
111.867
38.13°C
115.12V
2
13.806A
2.959A
2.976A
1.186A
199.630
91.552%
0
<6.0
42.76°C
0.989
12.227V
5.055V
3.321V
5.044V
218.050
38.69°C
115.11V
3
21.570A
3.466A
3.493A
1.391A
299.853
92.164%
0
<6.0
43.08°C
0.987
12.228V
5.053V
3.318V
5.027V
325.346
38.88°C
115.09V
4
29.317A
3.956A
3.977A
1.596A
399.688
92.141%
0
<6.0
43.81°C
0.991
12.229V
5.053V
3.316V
5.008V
433.781
39.40°C
115.08V
5
36.737A
4.957A
4.975A
1.801A
499.686
91.732%
610
22.2
39.27°C
0.993
12.227V
5.049V
3.314V
4.990V
544.721
44.87°C
115.08V
6
44.149A
5.943A
5.972A
2.010A
599.633
91.146%
630
26.8
40.56°C
0.995
12.228V
5.048V
3.313V
4.972V
657.884
47.17°C
115.08V
7
51.563A
6.939A
6.975A
2.219A
699.564
90.126%
1300
38.8
41.90°C
0.996
12.227V
5.047V
3.311V
4.952V
776.207
49.10°C
115.08V
8
58.980A
7.928A
7.975A
2.430A
799.468
89.097%
1795
49.0
42.78°C
0.997
12.226V
5.044V
3.310V
4.935V
897.302
50.34°C
115.08V
9
66.815A
8.436A
8.494A
2.433A
899.501
88.258%
2123
51.2
44.10°C
0.997
12.226V
5.042V
3.308V
4.928V
1019.175
51.89°C
115.09V
10
74.392A
8.930A
8.981A
3.065A
999.292
87.271%
2123
51.2
45.92°C
0.997
12.227V
5.041V
3.307V
4.889V
1145.045
53.94°C
115.10V
11
82.550A
8.933A
8.985A
3.070A
1099.129
86.072%
2132
51.7
47.77°C
0.998
12.228V
5.040V
3.305V
4.883V
1276.994
56.58°C
115.11V
CL1
0.098A
15.020A
15.002A
0.004A
127.086
86.561%
726
26.0
43.78°C
0.983
12.226V
5.059V
3.325V
5.101V
146.817
48.27°C
115.13V
CL2
82.933A
1.001A
1.003A
1.002A
1027.483
87.226%
2132
51.7
45.66°C
0.997
12.228V
5.044V
3.310V
4.999V
1177.951
52.79°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.400A
1.972A
1.984A
0.986A
99.802
90.644%
0
<6.0
48.84°C
0.837
12.226V
5.058V
3.323V
5.059V
110.103
38.81°C
230.22V
2
13.812A
2.959A
2.980A
1.190A
199.661
93.024%
600
22.2
39.55°C
0.934
12.222V
5.055V
3.321V
5.040V
214.633
49.93°C
230.21V
3
21.589A
3.467A
3.493A
1.391A
299.862
93.604%
600
22.2
39.63°C
0.960
12.218V
5.052V
3.318V
5.020V
320.353
50.51°C
230.20V
4
29.350A
3.961A
3.978A
1.600A
399.695
93.665%
600
22.2
39.98°C
0.972
12.215V
5.049V
3.315V
4.999V
426.729
51.24°C
230.24V
5
36.779A
4.959A
4.978A
1.806A
499.697
93.453%
620
22.4
40.68°C
0.981
12.213V
5.047V
3.313V
4.980V
534.702
52.35°C
230.21V
6
44.210A
5.944A
5.976A
2.015A
599.623
92.991%
910
28.4
41.44°C
0.984
12.211V
5.045V
3.312V
4.960V
644.815
53.31°C
230.21V
7
51.650A
6.947A
6.981A
2.225A
699.607
92.402%
1456
42.8
42.34°C
0.988
12.207V
5.042V
3.309V
4.939V
757.137
54.57°C
230.22V
8
59.085A
7.935A
7.982A
2.439A
799.447
91.695%
2043
48.8
43.40°C
0.989
12.204V
5.039V
3.307V
4.917V
871.850
56.14°C
230.21V
9
66.949A
8.444A
8.501A
2.443A
899.514
91.143%
2132
51.7
44.52°C
0.990
12.202V
5.036V
3.304V
4.908V
986.921
57.50°C
230.24V
10
74.558A
8.942A
8.991A
3.078A
999.311
90.479%
2132
51.7
46.14°C
0.990
12.200V
5.035V
3.303V
4.868V
1104.473
59.58°C
230.23V
11
82.750A
8.942A
8.997A
3.085A
1099.079
89.699%
2132
51.7
48.06°C
0.991
12.198V
5.034V
3.300V
4.859V
1225.301
62.21°C
230.22V
CL1
0.098A
15.020A
15.005A
0.005A
127.012
87.792%
1172
34.8
44.39°C
0.889
12.224V
5.054V
3.324V
5.096V
144.673
54.07°C
230.25V
CL2
82.938A
1.003A
1.003A
1.002A
1025.128
90.601%
2132
51.7
47.84°C
0.990
12.199V
5.042V
3.308V
4.982V
1131.477
59.77°C
230.23V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.491A
0.479A
0.196A
19.686
72.044%
0
<6.0
0.821
12.224V
5.062V
3.326V
5.108V
27.325
115.11V
2
2.411A
0.980A
0.991A
0.391A
39.716
81.911%
0
<6.0
0.920
12.224V
5.059V
3.323V
5.097V
48.487
115.11V
3
3.634A
1.476A
1.503A
0.585A
59.862
85.990%
0
<6.0
0.957
12.225V
5.058V
3.323V
5.087V
69.615
115.11V
4
4.840A
1.976A
1.983A
0.786A
79.746
87.487%
0
<6.0
0.968
12.226V
5.058V
3.323V
5.074V
91.152
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.491A
0.480A
0.196A
19.697
73.940%
0
<6.0
0.501
12.227V
5.064V
3.329V
5.108V
26.639
230.22V
2
2.413A
0.978A
0.991A
0.391A
39.740
83.454%
0
<6.0
0.660
12.227V
5.060V
3.326V
5.095V
47.619
230.23V
3
3.637A
1.476A
1.502A
0.589A
59.923
87.402%
0
<6.0
0.749
12.227V
5.059V
3.324V
5.084V
68.560
230.22V
4
4.841A
1.975A
1.982A
0.786A
79.750
89.419%
0
<6.0
0.802
12.226V
5.058V
3.324V
5.071V
89.187
230.22V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.6 mV
4.0 mV
6.6 mV
7.3 mV
Pass
20% Load
9.0 mV
4.9 mV
7.2 mV
8.3 mV
Pass
30% Load
10.7 mV
5.1 mV
7.3 mV
9.1 mV
Pass
40% Load
9.3 mV
4.3 mV
7.5 mV
10.6 mV
Pass
50% Load
8.0 mV
4.8 mV
8.0 mV
12.8 mV
Pass
60% Load
8.7 mV
4.7 mV
9.2 mV
15.0 mV
Pass
70% Load
8.8 mV
4.9 mV
9.4 mV
18.0 mV
Pass
80% Load
10.3 mV
5.3 mV
9.9 mV
18.3 mV
Pass
90% Load
11.2 mV
5.3 mV
10.9 mV
19.5 mV
Pass
100% Load
12.6 mV
6.2 mV
12.0 mV
29.3 mV
Pass
110% Load
19.6 mV
6.6 mV
12.8 mV
26.0 mV
Pass
Crossload 1
7.8 mV
5.1 mV
7.9 mV
6.7 mV
Pass
Crossload 2
14.3 mV
5.3 mV
11.2 mV
19.6 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.1 mV
4.0 mV
7.8 mV
7.4 mV
Pass
20% Load
9.9 mV
5.3 mV
8.6 mV
8.2 mV
Pass
30% Load
10.8 mV
5.1 mV
8.9 mV
8.9 mV
Pass
40% Load
9.4 mV
5.0 mV
8.6 mV
11.9 mV
Pass
50% Load
7.9 mV
5.5 mV
9.3 mV
13.1 mV
Pass
60% Load
8.3 mV
5.6 mV
9.3 mV
14.3 mV
Pass
70% Load
8.3 mV
5.6 mV
10.3 mV
18.1 mV
Pass
80% Load
9.3 mV
5.9 mV
11.2 mV
16.9 mV
Pass
90% Load
10.1 mV
5.9 mV
11.6 mV
19.4 mV
Pass
100% Load
16.2 mV
6.7 mV
12.4 mV
23.9 mV
Pass
110% Load
19.1 mV
7.1 mV
12.3 mV
25.8 mV
Pass
Crossload 1
9.1 mV
5.7 mV
9.8 mV
6.9 mV
Pass
Crossload 2
16.4 mV
6.0 mV
11.3 mV
18.7 mV
Pass
The results above are not used in the certification process
SeaSonic Prime Gold Ultra 1000W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted