This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
67.941%
0.032
5.130V
0.340
115.26V
2
0.090A
0.461
72.943%
0.059
5.129V
0.632
115.27V
3
0.550A
2.815
77.677%
0.265
5.118V
3.624
115.26V
4
1.000A
5.108
77.547%
0.361
5.108V
6.587
115.25V
5
1.500A
7.646
77.759%
0.412
5.098V
9.833
115.25V
6
3.000A
15.157
76.331%
0.478
5.053V
19.857
115.24V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.177A
1.991A
1.984A
0.980A
84.619
87.552%
0
<6.0
44.91°C
0.945
12.178V
5.013V
3.321V
5.105V
96.650
38.02°C
115.17V
2
11.350A
2.990A
2.977A
1.177A
169.116
91.040%
0
<6.0
45.88°C
0.985
12.180V
5.013V
3.321V
5.096V
185.761
38.37°C
115.16V
3
17.917A
3.489A
3.462A
1.376A
254.233
91.863%
0
<6.0
46.79°C
0.994
12.181V
5.014V
3.320V
5.087V
276.752
38.84°C
115.04V
4
24.479A
3.987A
3.975A
1.576A
339.437
91.626%
550
10.8
39.22°C
0.992
12.184V
5.013V
3.320V
5.077V
370.458
47.59°C
114.92V
5
30.714A
4.988A
4.971A
1.776A
424.776
91.241%
445
9.5
39.73°C
0.992
12.186V
5.012V
3.318V
5.068V
465.552
48.55°C
114.91V
6
36.880A
5.987A
5.969A
1.977A
509.289
90.814%
465
9.8
40.48°C
0.993
12.188V
5.011V
3.316V
5.059V
560.807
49.51°C
114.79V
7
43.116A
6.984A
6.966A
2.179A
594.625
90.300%
900
21.8
41.73°C
0.993
12.189V
5.010V
3.315V
5.049V
658.498
51.29°C
114.66V
8
49.358A
7.988A
7.966A
2.382A
679.973
89.719%
1495
32.0
42.92°C
0.994
12.188V
5.008V
3.313V
5.039V
757.893
52.87°C
114.64V
9
55.989A
8.489A
8.453A
2.384A
764.896
89.316%
2025
41.2
44.70°C
0.994
12.188V
5.007V
3.312V
5.034V
856.396
55.04°C
114.50V
10
62.359A
8.989A
8.971A
2.991A
849.734
88.711%
2035
41.3
45.66°C
0.995
12.188V
5.006V
3.311V
5.015V
957.872
57.09°C
114.47V
11
69.302A
8.990A
8.971A
2.994A
934.493
88.015%
2055
41.4
47.13°C
0.995
12.190V
5.006V
3.310V
5.011V
1061.741
59.62°C
114.33V
CL1
0.731A
12.000A
11.999A
0.000A
108.949
86.494%
465
9.8
43.68°C
0.968
12.185V
5.013V
3.324V
5.118V
125.961
52.87°C
115.22V
CL2
69.995A
1.001A
0.997A
1.000A
866.620
89.045%
2035
41.3
45.50°C
0.995
12.190V
5.009V
3.311V
5.066V
973.236
56.68°C
114.45V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.160A
0.497A
0.479A
0.195A
19.208
70.545%
0
<6.0
0.596
12.175V
5.017V
3.324V
5.125V
27.228
115.25V
2
2.411A
0.995A
0.991A
0.391A
39.632
80.697%
0
<6.0
0.821
12.175V
5.011V
3.320V
5.120V
49.112
115.23V
3
3.594A
1.493A
1.473A
0.587A
59.138
84.900%
0
<6.0
0.895
12.176V
5.012V
3.321V
5.115V
69.656
115.20V
4
4.843A
1.993A
1.984A
0.783A
79.557
87.132%
0
<6.0
0.936
12.178V
5.013V
3.321V
5.109V
91.306
115.17V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.3 mV
5.8 mV
5.5 mV
4.2 mV
Pass
20% Load
9.4 mV
6.8 mV
6.2 mV
4.5 mV
Pass
30% Load
11.5 mV
7.3 mV
6.8 mV
5.0 mV
Pass
40% Load
13.8 mV
8.0 mV
7.5 mV
5.8 mV
Pass
50% Load
15.2 mV
8.3 mV
8.3 mV
5.4 mV
Pass
60% Load
13.6 mV
9.3 mV
8.6 mV
6.1 mV
Pass
70% Load
13.4 mV
9.9 mV
9.4 mV
6.5 mV
Pass
80% Load
14.0 mV
10.2 mV
10.2 mV
6.7 mV
Pass
90% Load
16.0 mV
11.1 mV
10.6 mV
6.9 mV
Pass
100% Load
17.3 mV
11.8 mV
12.0 mV
7.8 mV
Pass
110% Load
19.5 mV
12.1 mV
12.1 mV
9.8 mV
Pass
Crossload 1
7.5 mV
11.5 mV
11.0 mV
3.9 mV
Pass
Crossload 2
18.0 mV
7.4 mV
7.2 mV
7.3 mV
Pass
The results above are not used in the certification process
Seasonic Focus Plus Platinum 850W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted