This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
48.131%
0.016
5.117V
0.479W
229.88V
2
0.09A
0.46W
55.775%
0.027
5.113V
0.826W
229.91V
3
0.55A
2.805W
75.098%
0.116
5.1V
3.735W
229.89V
4
1A
5.088W
77.328%
0.185
5.088V
6.581W
229.89V
5
1.5A
7.613W
78.224%
0.216
5.075V
9.734W
229.89V
6
3A
15.101W
77.357%
0.319
5.034V
19.522W
229.88V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.544A
1.95A
1.969A
0.983A
65.001
83.165%
756
19.2
34.41°C
0.818
12.245V
5.127V
3.352V
5.085V
78.158
38.64°C
229.87V
20%
8.096A
2.934A
2.962A
1.183A
129.928
88.137%
754
19.2
34.8°C
0.922
12.233V
5.113V
3.343V
5.072V
147.418
39.39°C
229.86V
30%
13.001A
3.43A
3.464A
1.383A
194.926
89.442%
757
19.2
35.14°C
0.953
12.221V
5.102V
3.334V
5.06V
217.937
40.27°C
229.85V
40%
17.921A
3.929A
3.971A
1.585A
260.006
89.722%
775
19.6
35.97°C
0.966
12.210V
5.09V
3.324V
5.049V
289.766
41.49°C
229.84V
50%
22.504A
4.926A
4.979A
1.787A
324.998
89.596%
1062
26.6
36.29°C
0.974
12.197V
5.076V
3.314V
5.036V
362.733
42.29°C
229.83V
60%
27.043A
5.928A
5.992A
1.991A
389.306
89.283%
1229
30.9
36.92°C
0.979
12.184V
5.061V
3.304V
5.023V
436.036
43.52°C
229.81V
70%
31.676A
6.937A
7.013A
2.196A
454.633
88.73%
1384
33.9
37.41°C
0.983
12.171V
5.046V
3.294V
5.009V
512.379
44.43°C
229.8V
80%
36.321A
7.951A
8.041A
2.301A
519.473
88.008%
1529
36.9
37.65°C
0.985
12.158V
5.03V
3.283V
4.998V
590.262
45.66°C
229.79V
90%
41.370A
8.467A
8.551A
2.406A
584.916
87.295%
1688
39.7
38.96°C
0.986
12.144V
5.018V
3.275V
4.987V
670.041
48.04°C
229.78V
100%
46.170A
8.989A
9.1A
3.023A
649.774
86.369%
1810
42.0
39.73°C
0.987
12.130V
5.006V
3.264V
4.963V
752.323
49.81°C
229.76V
110%
50.846A
10.027A
10.248A
3.028A
714.417
85.222%
1848
43.6
40.31°C
0.989
12.117V
4.986V
3.25V
4.955V
838.294
51.23°C
229.76V
CL1
0.115A
13.209A
13.281A
0A
111.301
82.053%
893
22.2
34.8°C
0.912
12.235V
5.011V
3.291V
5.097V
135.647
40.29°C
229.86V
CL2
0.113A
19.989A
0A
0A
101.336
81.956%
755
19.2
34.1°C
0.9
12.240V
5V
3.313V
5.102V
123.646
41.13°C
229.86V
CL3
0.113A
0A
20.054A
0A
67.395
76.546%
750
19.1
34.67°C
0.844
12.240V
5.078V
3.292V
5.102V
88.045
43.72°C
229.87V
CL4
53.525A
0A
0A
0.001A
649.542
86.548%
1721
40.1
40.02°C
0.988
12.135V
5.092V
3.306V
5.06V
750.507
50.99°C
229.76V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.212A
0.486A
0.49A
0.196A
19.995
69.278%
747
19
29.82°C
0.518
12.253V
5.148V
3.366V
5.111V
28.86
32.91°C
229.88V
40W
2.668A
0.68A
0.687A
0.294A
39.998
78.416%
742
18.8
31.47°C
0.705
12.249V
5.145V
3.363V
5.106V
51.011
34.81°C
229.87V
60W
4.126A
0.875A
0.884A
0.392A
60
83.232%
745
18.9
32.75°C
0.797
12.246V
5.14V
3.359V
5.102V
72.09
36.24°C
229.87V
80W
5.581A
1.071A
1.082A
0.49A
79.951
85.774%
749
19.1
33.03°C
0.856
12.242V
5.136V
3.356V
5.097V
93.213
36.89°C
229.87V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.97mV
10.78mV
9.92mV
11.92mV
Pass
20% Load
13.56mV
11.50mV
11.76mV
12.63mV
Pass
30% Load
14.07mV
11.80mV
13.71mV
14.32mV
Pass
40% Load
13.66mV
12.11mV
14.42mV
14.22mV
Pass
50% Load
14.63mV
13.69mV
17.19mV
16.73mV
Pass
60% Load
17.29mV
15.12mV
19.59mV
18.77mV
Pass
70% Load
17.55mV
16.09mV
21.74mV
20.82mV
Pass
80% Load
17.75mV
15.94mV
22.92mV
19.23mV
Pass
90% Load
24.92mV
18.44mV
25.27mV
22.30mV
Pass
100% Load
26.43mV
20.75mV
30.30mV
30.67mV
Pass
110% Load
29.86mV
22.16mV
32.00mV
31.87mV
Pass
Crossload1
19.13mV
16.17mV
19.65mV
15.80mV
Pass
Crossload2
16.47mV
22.17mV
15.55mV
11.92mV
Pass
Crossload3
15.55mV
10.83mV
17.60mV
14.58mV
Pass
Crossload4
29.77mV
18.07mV
27.20mV
23.17mV
Pass
The results above are not used in the certification process
Zalman GigaMax III 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted