This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
67.995%
0.048
5.113V
0.338W
114.93V
2
0.09A
0.46W
73.934%
0.086
5.112V
0.622W
114.93V
3
0.55A
2.807W
80.755%
0.325
5.104V
3.476W
114.94V
4
1A
5.096W
80.578%
0.412
5.097V
6.324W
114.94V
5
1.5A
7.633W
80.733%
0.45
5.089V
9.455W
114.93V
6
3A
15.188W
79.138%
0.505
5.063V
19.192W
114.93V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
56.377%
0.017
5.112V
0.408W
229.9V
2
0.09A
0.46W
66.572%
0.028
5.111V
0.692W
229.9V
3
0.55A
2.807W
78.959%
0.135
5.103V
3.555W
229.89V
4
1A
5.096W
80.289%
0.215
5.096V
6.347W
229.89V
5
1.5A
7.633W
80.654%
0.279
5.088V
9.464W
229.9V
6
3A
15.188W
80.079%
0.373
5.063V
18.967W
229.89V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.948A
1.989A
1.983A
0.983A
104.944
88.244%
0
<6.0
44.27°C
0.953
11.996V
5.026V
3.328V
5.088V
118.919
40.22°C
114.91V
20%
14.916A
2.986A
2.979A
1.182A
209.936
90.843%
0
<6.0
45.02°C
0.968
12.003V
5.023V
3.323V
5.077V
231.103
40.61°C
114.89V
30%
23.238A
3.486A
3.479A
1.382A
314.953
91.45%
0
<6.0
47.87°C
0.972
12.002V
5.021V
3.319V
5.066V
344.396
43.06°C
114.85V
40%
31.533A
3.985A
3.98A
1.582A
419.612
91.187%
813
24
42.06°C
0.978
12.000V
5.018V
3.316V
5.055V
460.164
47.07°C
114.84V
50%
39.544A
4.985A
4.981A
1.784A
524.936
90.777%
841
23
42.47°C
0.982
11.998V
5.015V
3.312V
5.044V
578.271
47.96°C
114.82V
60%
47.493A
5.986A
5.985A
1.987A
629.476
90.016%
1760
42.4
42.96°C
0.985
11.995V
5.012V
3.308V
5.033V
699.3
49.01°C
114.79V
70%
55.513A
6.989A
6.991A
2.191A
734.817
89.229%
1954
45.1
43.39°C
0.987
11.992V
5.009V
3.304V
5.022V
823.52
50.49°C
114.76V
80%
63.532A
7.993A
7.998A
2.295A
839.635
88.449%
1973
45.3
43.97°C
0.989
11.990V
5.006V
3.3V
5.012V
949.301
52.01°C
114.73V
90%
71.951A
8.496A
8.493A
2.399A
945.015
87.544%
1989
45.8
45.33°C
0.99
11.988V
5.003V
3.296V
5.002V
1079.477
54.35°C
114.7V
100%
80.099A
9.001A
9.022A
3.011A
1049.846
86.532%
2004
46.7
46.2°C
0.991
11.987V
5.001V
3.291V
4.983V
1213.262
56.25°C
114.66V
110%
88.119A
10.006A
10.129A
3.016A
1154.481
85.37%
2015
46.8
47.03°C
0.992
11.986V
4.998V
3.287V
4.974V
1352.33
58°C
114.63V
CL1
0.117A
14.413A
14.373A
0A
121.313
82.816%
851
23.8
42.33°C
0.962
12.002V
5.01V
3.318V
5.091V
146.491
47.84°C
114.9V
CL2
0.116A
19.996A
0A
0A
101.419
81.57%
471
16.1
37.77°C
0.953
12.001V
5.002V
3.319V
5.1V
124.343
45.01°C
114.9V
CL3
0.116A
0A
19.903A
0A
67.384
76.703%
737
23
42.06°C
0.943
11.997V
5.026V
3.316V
5.095V
87.854
51.08°C
114.91V
CL4
87.546A
0A
0A
0A
1049.805
86.892%
2001
46.5
45.8°C
0.991
11.992V
5.01V
3.291V
5.043V
1208.193
56.69°C
114.66V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.950A
1.991A
1.983A
0.983A
104.982
89.522%
0
<6.0
44.57°C
0.886
11.998V
5.024V
3.329V
5.086V
117.264
40.48°C
229.88V
20%
14.918A
2.988A
2.978A
1.182A
209.988
92.347%
0
<6.0
44.85°C
0.939
12.004V
5.021V
3.325V
5.075V
227.38
40.54°C
229.86V
30%
23.243A
3.488A
3.477A
1.382A
315.02
92.919%
458
14.2
41.05°C
0.955
12.002V
5.018V
3.322V
5.065V
339.011
45.81°C
229.85V
40%
31.547A
3.988A
3.978A
1.583A
419.741
92.924%
814
24
42.18°C
0.964
11.999V
5.016V
3.319V
5.055V
451.7
47.27°C
229.84V
50%
39.558A
4.988A
4.978A
1.785A
525.047
92.709%
830
25
42.36°C
0.97
11.996V
5.013V
3.315V
5.044V
566.337
47.82°C
229.82V
60%
47.509A
5.99A
5.981A
1.987A
629.589
92.221%
1652
43.5
42.92°C
0.974
11.993V
5.01V
3.311V
5.033V
682.707
49.01°C
229.82V
70%
55.529A
6.993A
6.987A
2.191A
734.922
91.679%
1951
45.2
43°C
0.976
11.990V
5.007V
3.307V
5.021V
801.618
50.04°C
229.8V
80%
63.546A
7.998A
7.995A
2.296A
839.789
91.138%
1981
45.6
45.57°C
0.978
11.989V
5.004V
3.302V
5.011V
921.445
53.62°C
229.79V
90%
71.970A
8.5A
8.488A
2.4A
945.065
90.654%
1988
45.8
44.34°C
0.981
11.985V
5.001V
3.299V
5.002V
1042.497
53.37°C
229.78V
100%
80.120A
9.006A
9.016A
3.011A
1049.933
89.962%
2004
46.7
45.89°C
0.983
11.985V
4.998V
3.294V
4.982V
1167.093
56.01°C
229.76V
110%
88.142A
10.012A
10.123A
3.017A
1154.595
89.141%
2011
46.9
47.15°C
0.984
11.984V
4.995V
3.289V
4.972V
1295.248
58.08°C
229.75V
CL1
0.117A
14.421A
14.364A
0A
121.326
83.938%
1191
35.3
45.18°C
0.909
12.002V
5.008V
3.32V
5.09V
144.55
50.64°C
229.88V
CL2
0.117A
20.005A
0A
0A
101.419
82.691%
818
25.5
43.44°C
0.892
12.000V
5V
3.32V
5.099V
122.658
50.45°C
229.87V
CL3
0.117A
0A
19.897A
0A
67.388
77.795%
816
24.7
42.47°C
0.85
11.997V
5.023V
3.317V
5.094V
86.618
51.51°C
229.88V
CL4
87.566A
0A
0A
0A
1049.89
90.275%
2009
46.7
47.06°C
0.983
11.990V
5.008V
3.293V
5.042V
1162.997
58.01°C
229.77V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.236A
0.497A
0.496A
0.196A
19.991
67.839%
0
<6.0
39.63°C
0.882
12.015V
5.027V
3.325V
5.109V
29.467
36.54°C
114.93V
40W
2.724A
0.696A
0.694A
0.294A
39.993
79.203%
0
<6.0
40.46°C
0.914
12.000V
5.027V
3.327V
5.105V
50.492
37.1°C
114.92V
60W
4.212A
0.895A
0.892A
0.392A
59.992
84.035%
0
<6.0
41.64°C
0.937
11.997V
5.028V
3.33V
5.102V
71.392
37.94°C
114.92V
80W
5.694A
1.094A
1.09A
0.49A
79.935
86.735%
0
<6.0
42.03°C
0.947
11.996V
5.027V
3.329V
5.099V
92.157
38.01°C
114.91V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.240A
0.5A
0.5A
0.2A
20.145
69.608%
0
<6.0
39.61°C
0.621
12.048V
5.024V
3.324V
5.107V
28.943
36.58°C
229.89V
40W
2.720A
0.7A
0.7A
0.3A
40.061
80.694%
0
<6.0
41.24°C
0.756
12.013V
5.025V
3.327V
5.103V
49.642
37.93°C
229.88V
60W
4.210A
0.895A
0.892A
0.392A
60.007
85.475%
0
<6.0
42.47°C
0.818
12.002V
5.025V
3.331V
5.1V
70.204
39°C
229.88V
80W
5.696A
1.095A
1.09A
0.491A
79.969
87.902%
0
<6.0
42.86°C
0.856
11.999V
5.025V
3.331V
5.097V
90.976
39.06°C
229.88V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
19.78mV
4.54mV
6.70mV
6.34mV
Pass
20% Load
22.54mV
5.52mV
6.75mV
7.37mV
Pass
30% Load
16.81mV
5.62mV
7.16mV
8.65mV
Pass
40% Load
15.89mV
6.43mV
8.85mV
9.62mV
Pass
50% Load
13.58mV
6.13mV
7.93mV
9.83mV
Pass
60% Load
14.51mV
6.79mV
8.49mV
10.64mV
Pass
70% Load
14.81mV
7.56mV
8.28mV
11.51mV
Pass
80% Load
15.38mV
7.46mV
9.77mV
11.51mV
Pass
90% Load
15.53mV
7.30mV
11.10mV
12.03mV
Pass
100% Load
25.05mV
9.04mV
10.31mV
13.18mV
Pass
110% Load
26.35mV
9.52mV
12.26mV
13.26mV
Pass
Crossload1
30.33mV
6.17mV
8.86mV
9.03mV
Pass
Crossload2
20.75mV
5.52mV
6.70mV
8.70mV
Pass
Crossload3
5.68mV
4.85mV
10.23mV
8.14mV
Pass
Crossload4
25.02mV
8.01mV
8.93mV
14.04mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.19mV
4.75mV
6.65mV
6.29mV
Pass
20% Load
22.39mV
5.01mV
7.00mV
7.06mV
Pass
30% Load
17.12mV
5.87mV
6.85mV
8.19mV
Pass
40% Load
17.58mV
6.08mV
7.67mV
8.80mV
Pass
50% Load
14.20mV
6.03mV
7.16mV
9.62mV
Pass
60% Load
14.66mV
6.13mV
7.46mV
10.49mV
Pass
70% Load
14.87mV
7.20mV
8.44mV
10.60mV
Pass
80% Load
15.43mV
7.30mV
9.16mV
10.75mV
Pass
90% Load
16.35mV
7.46mV
10.38mV
11.36mV
Pass
100% Load
24.27mV
8.69mV
10.40mV
12.36mV
Pass
110% Load
25.79mV
9.29mV
11.81mV
12.41mV
Pass
Crossload1
34.00mV
6.13mV
10.54mV
9.15mV
Pass
Crossload2
22.60mV
5.16mV
7.42mV
8.85mV
Pass
Crossload3
6.09mV
4.80mV
10.69mV
8.55mV
Pass
Crossload4
25.35mV
7.78mV
8.57mV
13.72mV
Pass
The results above are not used in the certification process
Cooler Master MWE Gold 1050 V2 (ATX v3.0)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted