This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
230V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228W
53.947%
0.017
5.07V
0.425W
229.9V
2
0.09A
0.456W
63.189%
0.029
5.069V
0.723W
229.89V
3
0.55A
2.778W
75.672%
0.133
5.051V
3.671W
229.9V
4
1A
5.035W
77.166%
0.208
5.035V
6.527W
229.89V
5
1.5A
7.527W
77.945%
0.247
5.018V
9.657W
229.89V
6
2.5A
12.453W
77.925%
0.315
4.981V
15.98W
229.9V
Supplementary Tests (For Reference)
230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
3.990A
1.952A
1.957A
0.994A
69.994
84.159%
837
18.8
34.18°C
0.858
12.130V
5.121V
3.373V
5.03V
83.167
38.44°C
229.89V
20%
8.991A
2.933A
2.943A
1.197A
139.916
88.598%
1081
26.3
34.62°C
0.945
12.125V
5.113V
3.364V
5.013V
157.922
39.22°C
229.87V
30%
14.347A
3.426A
3.441A
1.401A
209.952
89.647%
1359
31.5
35.15°C
0.971
12.121V
5.107V
3.356V
4.997V
234.199
40.12°C
229.86V
40%
19.706A
3.921A
3.942A
1.607A
279.992
89.847%
1576
34.9
35.79°C
0.982
12.117V
5.1V
3.348V
4.98V
311.63
41.24°C
229.85V
50%
24.719A
4.909A
4.942A
1.814A
349.943
89.698%
1736
39.3
36.47°C
0.987
12.114V
5.092V
3.339V
4.962V
390.132
42.35°C
229.84V
60%
29.715A
5.9A
5.946A
2A
419.579
89.239%
1800
39.1
36.89°C
0.989
12.111V
5.085V
3.33V
4.945V
470.172
43.22°C
229.83V
70%
34.744A
6.894A
6.957A
2.233A
489.809
88.687%
1804
39.1
36.98°C
0.992
12.108V
5.078V
3.321V
4.925V
552.291
43.99°C
229.81V
80%
39.774A
7.89A
7.971A
2.342A
559.43
87.97%
1809
39.1
37.57°C
0.993
12.107V
5.07V
3.312V
4.911V
635.937
45.58°C
229.8V
90%
45.203A
8.393A
8.475A
2.45A
629.674
87.176%
1813
39.1
38.71°C
0.995
12.105V
5.064V
3.304V
4.897V
722.303
47.77°C
229.79V
100%
50.629A
8.897A
9.012A
2.56A
699.998
86.22%
1815
39.1
39.8°C
0.995
12.103V
5.058V
3.295V
4.882V
811.876
49.81°C
229.78V
110%
55.655A
9.902A
10.135A
2.567A
769.414
85.07%
1817
39.1
41.09°C
0.996
12.103V
5.05V
3.285V
4.87V
904.449
52.02°C
229.76V
CL1
1.978A
11.822A
11.88A
0.497A
126.411
83.726%
1402
32.1
34.81°C
0.938
12.140V
5.092V
3.342V
5.026V
150.981
40.32°C
229.88V
CL2
1.977A
11.106A
0.981A
0.496A
86.507
83.706%
1066
26.9
34.22°C
0.893
12.140V
5.106V
3.365V
5.044V
103.347
41.26°C
229.88V
CL3
1.978A
0.977A
10.294A
0.496A
66.093
81.2%
924
20.5
34.89°C
0.851
12.133V
5.119V
3.361V
5.04V
81.396
44.03°C
229.88V
CL4
56.944A
0.984A
0.994A
0.502A
699.436
87.196%
1806
39.1
38.74°C
0.995
12.093V
5.08V
3.319V
4.978V
802.153
49.67°C
229.78V
The results above are not used in the certification process
230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.224A
0.487A
0.488A
0.197A
19.989
67.538%
553
12.6
30.59°C
0.552
12.125V
5.128V
3.381V
5.067V
29.598
33.65°C
229.89V
40W
2.695A
0.683A
0.684A
0.296A
39.991
78.948%
559
12.8
31.52°C
0.731
12.127V
5.126V
3.379V
5.061V
50.655
34.83°C
229.89V
60W
4.166A
0.878A
0.879A
0.396A
59.991
83.758%
580
13.4
32.9°C
0.825
12.128V
5.125V
3.377V
5.055V
71.625
36.38°C
229.89V
80W
5.632A
1.073A
1.076A
0.495A
79.925
86.105%
763
18.8
33.48°C
0.878
12.127V
5.123V
3.374V
5.049V
92.822
37.32°C
229.89V
The results above are not used in the certification process
230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.58mV
12.93mV
11.29mV
14.06mV
Pass
20% Load
15.65mV
13.45mV
12.31mV
15.29mV
Pass
30% Load
16.72mV
14.73mV
12.57mV
15.55mV
Pass
40% Load
22.91mV
15.55mV
12.93mV
16.21mV
Pass
50% Load
23.68mV
16.17mV
14.62mV
17.75mV
Pass
60% Load
25.88mV
18.02mV
15.39mV
17.55mV
Pass
70% Load
28.44mV
18.58mV
17.08mV
18.42mV
Pass
80% Load
32.53mV
20.27mV
24.16mV
18.47mV
Pass
90% Load
38.72mV
20.53mV
26.63mV
19.50mV
Pass
100% Load
51.65mV
23.68mV
31.53mV
23.58mV
Pass
110% Load
58.37mV
23.91mV
34.93mV
24.96mV
Pass
Crossload1
25.66mV
21.52mV
28.17mV
16.62mV
Pass
Crossload2
16.57mV
15.91mV
13.65mV
13.44mV
Pass
Crossload3
12.89mV
14.68mV
20.37mV
12.31mV
Pass
Crossload4
49.69mV
20.41mV
21.18mV
20.60mV
Pass
The results above are not used in the certification process