This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228W
71.119%
0.032
5.068V
0.321W
115.15V
2
0.09A
0.456W
75.298%
0.059
5.066V
0.606W
115.15V
3
0.55A
2.781W
79.741%
0.258
5.054V
3.488W
115.16V
4
1A
5.045W
79.761%
0.342
5.044V
6.326W
115.15V
5
1.5A
7.553W
80.17%
0.39
5.034V
9.421W
115.15V
6
3A
15.009W
78.465%
0.456
5.003V
19.129W
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228W
61.6%
0.011
5.069V
0.371W
230.35V
2
0.09A
0.456W
67.764%
0.02
5.067V
0.674W
230.35V
3
0.55A
2.78W
77.429%
0.102
5.054V
3.593W
230.35V
4
1A
5.046W
78.769%
0.167
5.045V
6.407W
230.35V
5
1.5A
7.554W
79.653%
0.22
5.035V
9.482W
230.35V
6
3A
15.011W
80.069%
0.317
5.003V
18.749W
230.34V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.488A
1.996A
2.007A
0.992A
100.028
85.483%
0
<6.0
44.49°C
0.982
12.089V
5.012V
3.289V
5.043V
117.02
40.18°C
115.14V
20%
13.991A
2.996A
3.013A
1.193A
199.985
90.825%
0
<6.0
45.3°C
0.99
12.085V
5.007V
3.286V
5.032V
220.186
40.61°C
115.11V
30%
21.891A
3.498A
3.518A
1.372A
300.033
91.478%
0
<6.0
46.49°C
0.987
12.059V
5.003V
3.284V
5.104V
327.98
41.56°C
115.08V
40%
29.755A
4.001A
4.023A
1.57A
399.755
91.124%
0
<6.0
47.22°C
0.987
12.050V
5V
3.282V
5.096V
438.689
41.74°C
115.05V
50%
37.284A
5.007A
5.033A
1.771A
499.49
90.531%
438
8.2
42.42°C
0.988
12.042V
4.994V
3.279V
5.084V
551.733
48.35°C
115.01V
60%
44.880A
6.013A
6.044A
1.972A
600.005
89.814%
701
20.9
42.94°C
0.99
12.036V
4.99V
3.276V
5.072V
668.049
49.55°C
114.98V
70%
52.427A
7.02A
7.055A
2.175A
699.726
89.039%
823
26.2
43.25°C
0.992
12.028V
4.987V
3.274V
5.058V
785.872
50.52°C
114.96V
80%
60.056A
8.002A
8.067A
2.278A
799.662
88.15%
1053
33.7
43.54°C
0.993
12.020V
4.984V
3.272V
5.048V
907.161
51.58°C
114.92V
90%
68.011A
8.535A
8.562A
2.382A
899.553
87.177%
1507
43.7
44.05°C
0.994
12.014V
4.98V
3.27V
5.038V
1031.87
53.13°C
114.89V
100%
75.777A
9.045A
9.087A
2.99A
999.571
86.095%
1881
50.0
45.15°C
0.995
12.008V
4.975V
3.268V
5.017V
1161.021
55.19°C
114.86V
110%
83.485A
10.057A
10.197A
2.995A
1100.202
84.857%
2161
53.0
46.98°C
0.995
12.001V
4.971V
3.265V
5.008V
1296.549
57.87°C
114.83V
CL1
0.116A
14.423A
14.568A
0A
121.3
82.673%
441
8.2
42.58°C
0.988
12.086V
5.006V
3.274V
5.048V
146.719
48.04°C
115.12V
CL2
0.115A
21.91A
0A
0A
111.395
80.958%
439
8.2
43.88°C
0.986
12.094V
5.02V
3.28V
5.063V
137.597
50.09°C
115.12V
CL3
0.115A
0A
22.182A
0A
73.989
75.017%
439
8.2
44.03°C
0.98
12.088V
5.008V
3.273V
5.047V
98.629
52.14°C
115.13V
CL4
83.249A
0A
0A
0A
1000.054
86.979%
1766
48.1
45.38°C
0.994
12.012V
4.994V
3.283V
5.096V
1149.78
55.35°C
114.87V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.488A
1.995A
2.007A
0.992A
100.004
86.654%
0
<6.0
44.78°C
0.895
12.085V
5.012V
3.289V
5.043V
115.401
40.42°C
230.37V
20%
14.009A
2.996A
3.013A
1.193A
199.961
91.882%
0
<6.0
45.74°C
0.952
12.068V
5.007V
3.286V
5.031V
217.632
41.04°C
230.36V
30%
21.917A
3.498A
3.517A
1.372A
300.012
92.798%
0
<6.0
46.85°C
0.968
12.043V
5.003V
3.284V
5.103V
323.287
41.7°C
230.35V
40%
29.790A
4.001A
4.023A
1.571A
399.724
92.783%
0
<6.0
47.82°C
0.976
12.035V
5V
3.282V
5.095V
430.813
42.17°C
230.34V
50%
37.293A
5.007A
5.033A
1.771A
499.498
92.527%
413
7.7
42.75°C
0.978
12.039V
4.994V
3.279V
5.082V
539.839
48.76°C
230.33V
60%
44.896A
6.013A
6.044A
1.973A
600.03
92.071%
652
18.5
43.11°C
0.981
12.032V
4.991V
3.276V
5.07V
651.708
49.68°C
230.32V
70%
52.437A
7.019A
7.056A
2.175A
699.771
91.575%
882
28.4
43.2°C
0.983
12.027V
4.988V
3.274V
5.058V
764.15
50.29°C
230.3V
80%
60.059A
8.003A
8.068A
2.279A
799.69
90.988%
1197
37.3
43.62°C
0.984
12.020V
4.984V
3.272V
5.047V
878.896
51.64°C
230.29V
90%
68.023A
8.535A
8.562A
2.383A
899.606
90.381%
1508
43.7
44.33°C
0.985
12.012V
4.98V
3.27V
5.037V
995.35
53.55°C
230.28V
100%
75.800A
9.045A
9.088A
2.991A
999.633
89.64%
1885
50.0
45.35°C
0.986
12.005V
4.976V
3.268V
5.016V
1115.157
55.36°C
230.26V
110%
83.512A
10.058A
10.198A
2.996A
1100.274
88.805%
2162
53.0
46.59°C
0.987
11.998V
4.971V
3.265V
5.007V
1238.972
57.46°C
230.25V
CL1
0.116A
14.423A
14.57A
0A
121.309
83.148%
441
8.2
42.08°C
0.923
12.084V
5.006V
3.274V
5.047V
145.893
48.58°C
230.38V
CL2
0.116A
21.917A
0A
0A
111.402
81.693%
439
8.2
43.81°C
0.917
12.093V
5.019V
3.281V
5.062V
136.366
50.86°C
230.38V
CL3
0.116A
0A
22.185A
0A
73.995
74.908%
438
8.2
43.74°C
0.871
12.088V
5.008V
3.272V
5.046V
98.782
52.04°C
230.39V
CL4
83.263A
0A
0A
0A
1000.136
90.393%
1771
48.1
45.55°C
0.986
12.011V
4.994V
3.282V
5.095V
1106.441
55.53°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.230A
0.497A
0.5A
0.197A
20.007
60.887%
0
<6.0
39.94°C
0.918
12.086V
5.031V
3.3V
5.066V
32.858
36.81°C
115.16V
40W
2.705A
0.696A
0.7A
0.296A
40.005
67.046%
0
<6.0
40.98°C
0.967
12.087V
5.03V
3.3V
5.063V
59.674
37.62°C
115.15V
60W
4.180A
0.897A
0.902A
0.395A
60.005
81.974%
0
<6.0
43.04°C
0.969
12.088V
5.02V
3.294V
5.06V
73.198
39.36°C
115.15V
80W
5.654A
1.097A
1.103A
0.495A
79.972
84.992%
0
<6.0
43.66°C
0.979
12.089V
5.015V
3.291V
5.056V
94.094
39.73°C
115.14V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.497A
0.5A
0.197A
19.998
60.747%
0
<6.0
39.7°C
0.576
12.089V
5.032V
3.3V
5.067V
32.918
36.59°C
230.38V
40W
2.704A
0.696A
0.7A
0.296A
39.998
67.571%
0
<6.0
41.09°C
0.762
12.088V
5.031V
3.3V
5.064V
59.197
37.8°C
230.37V
60W
4.180A
0.896A
0.901A
0.395A
59.997
82.759%
0
<6.0
42.06°C
0.809
12.087V
5.021V
3.294V
5.06V
72.494
38.6°C
230.38V
80W
5.654A
1.097A
1.103A
0.495A
79.951
85.312%
0
<6.0
42.61°C
0.861
12.085V
5.015V
3.291V
5.056V
93.71
38.87°C
230.38V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.20mV
5.62mV
4.96mV
6.02mV
Pass
20% Load
18.01mV
6.39mV
5.12mV
6.17mV
Pass
30% Load
14.75mV
6.80mV
5.73mV
6.27mV
Pass
40% Load
13.42mV
7.21mV
6.55mV
8.06mV
Pass
50% Load
12.50mV
9.31mV
10.70mV
7.75mV
Pass
60% Load
12.96mV
8.18mV
7.17mV
7.80mV
Pass
70% Load
13.67mV
8.69mV
7.57mV
9.33mV
Pass
80% Load
14.30mV
9.10mV
12.44mV
9.59mV
Pass
90% Load
14.80mV
10.69mV
13.10mV
9.79mV
Pass
100% Load
24.16mV
11.54mV
15.16mV
11.35mV
Pass
110% Load
24.58mV
12.25mV
15.34mV
11.52mV
Pass
Crossload1
9.08mV
10.69mV
14.58mV
12.10mV
Pass
Crossload2
8.99mV
13.25mV
6.19mV
10.81mV
Pass
Crossload3
7.20mV
5.32mV
16.84mV
9.59mV
Pass
Crossload4
20.26mV
9.39mV
9.04mV
13.62mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.51mV
5.52mV
4.50mV
5.56mV
Pass
20% Load
17.96mV
6.09mV
4.97mV
7.60mV
Pass
30% Load
13.83mV
6.45mV
5.48mV
6.17mV
Pass
40% Load
13.57mV
7.21mV
6.04mV
8.21mV
Pass
50% Load
12.55mV
8.90mV
10.03mV
7.44mV
Pass
60% Load
12.70mV
8.03mV
7.11mV
7.75mV
Pass
70% Load
13.47mV
8.80mV
7.57mV
8.62mV
Pass
80% Load
13.67mV
9.15mV
12.54mV
8.92mV
Pass
90% Load
14.39mV
10.23mV
13.10mV
9.79mV
Pass
100% Load
25.08mV
11.27mV
14.90mV
10.52mV
Pass
110% Load
26.02mV
11.99mV
14.92mV
10.89mV
Pass
Crossload1
8.89mV
10.30mV
14.01mV
11.14mV
Pass
Crossload2
10.62mV
12.94mV
7.88mV
13.92mV
Pass
Crossload3
6.95mV
5.47mV
16.74mV
9.69mV
Pass
Crossload4
21.61mV
9.07mV
8.77mV
12.35mV
Pass
The results above are not used in the certification process
Superframe SF-G1000M
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted