This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC) 230V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
52.429%
0.008
5.046V
0.434W
230.28V
2
0.09A
0.454W
64.27%
0.012
5.044V
0.707W
230.28V
3
0.55A
2.769W
82.941%
0.057
5.033V
3.338W
230.28V
4
1A
5.022W
85.161%
0.1
5.021V
5.897W
230.28V
5
1.5A
7.514W
86.337%
0.143
5.009V
8.703W
230.28V
6
3A
14.915W
84.03%
0.257
4.971V
17.749W
230.27V
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
14.831A
2.003A
1.975A
0.998A
199.996
87.39%
768
22.9
40.28°C
0.886
12.029V
4.993V
3.342V
5.011V
228.859
45.38°C
230.26V
20%
30.699A
3.009A
2.971A
1.201A
399.674
93.218%
1062
32.8
40.79°C
0.966
12.013V
4.984V
3.331V
4.996V
428.71
46.25°C
230.24V
30%
46.944A
3.517A
3.477A
1.406A
599.257
94.01%
1311
39.0
41.6°C
0.982
11.998V
4.976V
3.321V
4.98V
637.41
47.43°C
230.21V
40%
63.304A
4.023A
3.986A
1.611A
799.659
94.168%
1492
42.4
41.75°C
0.984
11.981V
4.971V
3.311V
4.964V
849.14
48.26°C
230.19V
50%
79.292A
5.039A
4.999A
1.819A
999.311
94.161%
1697
46.1
42.28°C
0.985
11.966V
4.961V
3.3V
4.949V
1061.313
49.23°C
230.17V
60%
95.418A
6.06A
6.023A
2A
1199.735
93.939%
1820
47.6
42.86°C
0.985
11.948V
4.95V
3.287V
4.933V
1277.143
50.03°C
230.14V
70%
111.508A
7.086A
7.052A
2.238A
1399.601
93.654%
1839
47.7
43.36°C
0.986
11.932V
4.94V
3.276V
4.915V
1494.358
50.87°C
230.12V
80%
127.717A
8.002A
8.088A
2.346A
1599.052
93.214%
2224
53.1
44.2°C
0.986
11.915V
4.93V
3.263V
4.901V
1715.555
52.3°C
230.09V
90%
144.311A
8.639A
8.608A
2.456A
1799.45
92.734%
2199
53.0
44.61°C
0.987
11.898V
4.92V
3.252V
4.887V
1940.386
53.89°C
230.07V
100%
160.778A
9.168A
9.166A
3.088A
1999.489
92.288%
2191
52.7
46.17°C
0.988
11.878V
4.909V
3.239V
4.858V
2166.324
56.05°C
230.04V
CL1
0.116A
14.523A
14.403A
0A
121.294
77.934%
1565
43.8
42.21°C
0.831
12.020V
4.972V
3.311V
5.034V
155.746
48.35°C
230.27V
CL2
0.116A
22.152A
0A
0A
111.406
76.495%
1283
38.4
43.27°C
0.828
12.028V
4.967V
3.339V
5.04V
145.7
50.41°C
230.27V
CL3
0.116A
0A
25.06A
0A
83.872
68.971%
1196
37.3
44.17°C
0.836
12.027V
4.987V
3.291V
5.035V
121.627
52.78°C
230.27V
CL4
168.095A
0A
0A
0A
1999.775
92.879%
2266
53.2
45.39°C
0.988
11.897V
4.928V
3.264V
4.954V
2153.432
54.73°C
230.04V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.5A
0.492A
0.198A
19.999
40.442%
748
21.9
37.01°C
0.322
12.050V
5.003V
3.354V
5.042V
31.841
40.22°C
230.28V
40W
2.712A
0.7A
0.689A
0.298A
39.997
71.307%
750
22.0
37.37°C
0.533
12.049V
5.003V
3.353V
5.039V
56.051
40.89°C
230.28V
60W
4.196A
0.9A
0.886A
0.397A
59.996
56.142%
752
22.1
38.44°C
0.664
12.042V
5V
3.351V
5.035V
81.566
42.36°C
230.28V
80W
5.675A
1.1A
1.084A
0.497A
79.943
70.437%
753
22.1
38.54°C
0.776
12.038V
5V
3.35V
5.031V
103.154
42.77°C
230.27V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.85mV
12.10mV
8.13mV
5.68mV
Pass
20% Load
11.10mV
12.62mV
9.10mV
5.78mV
Pass
30% Load
13.10mV
14.15mV
10.48mV
6.40mV
Pass
40% Load
16.22mV
13.18mV
9.15mV
6.81mV
Pass
50% Load
18.63mV
13.03mV
9.82mV
6.76mV
Pass
60% Load
23.13mV
13.53mV
10.38mV
7.47mV
Pass
70% Load
25.23mV
13.43mV
11.61mV
7.83mV
Pass
80% Load
34.34mV
17.01mV
17.49mV
10.24mV
Pass
90% Load
37.76mV
14.35mV
13.86mV
9.26mV
Pass
100% Load
41.49mV
14.78mV
14.16mV
9.92mV
Pass
110% Load
0.00mV
0.00mV
0.00mV
0.00mV
Pass
Crossload1
13.81mV
14.55mV
13.95mV
5.05mV
Pass
Crossload2
9.16mV
14.71mV
7.57mV
5.02mV
Pass
Crossload3
11.72mV
11.49mV
16.11mV
4.86mV
Pass
Crossload4
41.70mV
10.37mV
9.58mV
11.36mV
Pass
The results above are not used in the certification process
Cooler Master M2000 Platinum
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case