SATA (550mm) / 4-pin Molex (+155mm+155mm+155mm) / FDD (+100mm)
1
1 / 3 / 1
18-22AWG
No
Modular Cables
AC Power Cord (1720mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
GOLD
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
88.628%
Average Noise Output (>1450 Load Combinations)
35.39dBA
Average PF (>1450 Load Combinations)
0.993
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.559%
Standby Power Consumption
0.0972W
12V Ripple (Full Load)
68.44mV
5V Ripple (Full Load)
58.22mV
3.3V Ripple (Full Load)
36.75mV
5VSB Ripple (Full Load)
20.37mV
12V Load Regulation
2.81%
5V Load Regulation
1.04%
3.3V Load Regulation
2.96%
5VSB Load Regulation
3.02%
Inrush Current
35.740A
Efficiency Rating
GOLD
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
90.252%
Average Noise Output (>1450 Load Combinations)
35.37dBA
Average PF (>1450 Load Combinations)
0.977
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1568W
12V Ripple (Full Load)
70.00mV
5V Ripple (Full Load)
61.90mV
3.3V Ripple (Full Load)
36.41mV
5VSB Ripple (Full Load)
21.26mV
12V Load Regulation
2.65%
5V Load Regulation
0.90%
3.3V Load Regulation
2.74%
5VSB Load Regulation
2.99%
Inrush Current
79.960A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
21.20ms
AC Loss to PWR_OK Hold Up Time
19.40ms
PWR_OK Inactive to DC Loss Delay
1.80ms
PSU Timings: T1 (20% / 100%)
57.0ms
52.0ms
PSU Timings: T3 (20% / 100%)
273.0ms
275.0ms
OPP (24.86°C / 39.00°C)
113.91%
113.89%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.2
AC Loss to PWR_OK Hold Up Time (ms)
19.4
PWR_OK Inactive to DC Loss Delay (ms)
1.8
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
62.872%
0.071
5.033V
0.361W
115.14V
2
0.09A
0.453W
71.855%
0.116
5.032V
0.63W
115.15V
3
0.55A
2.764W
78.626%
0.286
5.024V
3.515W
115.14V
4
1A
5.016W
80.122%
0.33
5.015V
6.26W
115.14V
5
1.5A
7.509W
79.885%
0.356
5.005V
9.4W
115.14V
6
3A
14.935W
77.953%
0.39
4.978V
19.159W
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227W
49.903%
0.027
5.032V
0.455W
230.35V
2
0.09A
0.453W
63.027%
0.043
5.032V
0.719W
230.35V
3
0.55A
2.764W
76.824%
0.164
5.024V
3.598W
230.34V
4
1A
5.017W
77.734%
0.233
5.015V
6.454W
230.34V
5
1.5A
7.512W
77.414%
0.276
5.007V
9.703W
230.34V
6
3A
14.936W
78.534%
0.332
4.978V
19.018W
230.34V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.338A
1.958A
2.002A
1A
50.006
84.846%
972
26.2
34.54°C
0.953
12.148V
5.107V
3.296V
5.001V
58.937
37.35°C
115.15V
20%
5.707A
2.937A
3.012A
1.203A
99.953
88.956%
1029
28.1
35.5°C
0.976
12.099V
5.109V
3.287V
4.988V
112.362
38.84°C
115.15V
30%
9.449A
3.426A
3.523A
1.407A
149.991
90.152%
1107
30.0
36.02°C
0.987
12.058V
5.109V
3.279V
4.976V
166.375
39.83°C
115.15V
40%
13.212A
3.914A
4.036A
1.612A
200.032
90.333%
1186
31.9
36.43°C
0.992
12.021V
5.112V
3.271V
4.963V
221.437
40.54°C
115.15V
50%
16.624A
4.898A
5.06A
1.819A
249.983
90.065%
1277
33.7
36.58°C
0.996
12.000V
5.105V
3.261V
4.949V
277.557
41.53°C
115.16V
60%
20.060A
5.886A
6.089A
2.001A
299.894
89.644%
1360
35.6
37.59°C
0.997
11.974V
5.098V
3.252V
4.936V
334.539
42.88°C
115.16V
70%
23.513A
6.878A
7.128A
2.236A
350.061
89.022%
1462
37.7
37.71°C
0.997
11.948V
5.091V
3.241V
4.921V
393.227
43.54°C
115.16V
80%
26.987A
7.869A
8.173A
2.343A
399.688
88.394%
1474
37.9
38.62°C
0.998
11.923V
5.085V
3.23V
4.909V
452.168
44.74°C
115.16V
90%
30.970A
8.35A
8.692A
2.451A
449.916
87.738%
1467
37.8
39.13°C
0.998
11.863V
5.091V
3.221V
4.897V
512.794
45.63°C
115.16V
100%
34.678A
8.84A
9.251A
3.077A
499.534
86.814%
1470
37.8
39.5°C
0.998
11.818V
5.091V
3.21V
4.875V
575.405
46.65°C
115.16V
110%
38.315A
9.84A
10.411A
3.085A
549.756
85.787%
1470
37.8
40.05°C
0.999
11.783V
5.082V
3.198V
4.863V
640.837
47.78°C
115.17V
CL1
1.904A
14.862A
14.682A
0.505A
146.419
84.878%
1519
38.6
36.42°C
0.988
12.611V
4.858V
3.249V
4.955V
172.504
41.25°C
115.17V
CL2
1.908A
19.753A
1.01A
0.502A
126.517
86.352%
1417
36.8
37.28°C
0.985
12.582V
4.896V
3.268V
4.979V
146.512
42.85°C
115.16V
CL3
1.946A
1.004A
22.744A
0.504A
105.706
82.021%
1178
31.6
38.08°C
0.981
12.333V
4.983V
3.262V
4.96V
128.877
44.53°C
115.16V
CL4
42.640A
0.952A
1.02A
0.506A
499.747
86.633%
1445
37.4
39.41°C
0.998
11.466V
5.251V
3.236V
4.94V
576.859
46.47°C
115.16V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
2.342A
1.964A
2.007A
1A
50.004
84.052%
1033
28.2
35.61°C
0.868
12.130V
5.092V
3.289V
5.001V
59.492
38.53°C
230.32V
20%
5.718A
2.939A
3.017A
1.203A
99.948
89.211%
1065
29.1
35.94°C
0.935
12.074V
5.104V
3.281V
4.988V
112.034
39.15°C
230.32V
30%
9.471A
3.432A
3.53A
1.407A
149.987
90.836%
1136
30.5
36°C
0.96
12.028V
5.101V
3.272V
4.975V
165.118
39.59°C
230.32V
40%
13.244A
3.921A
4.045A
1.612A
200.028
91.38%
1208
32.4
36.24°C
0.974
11.992V
5.103V
3.264V
4.963V
218.897
40.25°C
230.33V
50%
16.650A
4.904A
5.066A
1.819A
249.966
91.525%
1196
32.2
37.38°C
0.982
11.980V
5.099V
3.257V
4.95V
273.112
41.69°C
230.34V
60%
20.088A
5.893A
6.1A
2.001A
299.887
91.299%
1324
34.8
37.85°C
0.985
11.957V
5.093V
3.246V
4.936V
328.465
42.7°C
230.34V
70%
23.542A
6.883A
7.144A
2.236A
350.054
90.979%
1431
37.1
38.34°C
0.988
11.933V
5.087V
3.234V
4.92V
384.766
43.54°C
230.35V
80%
27.043A
7.869A
8.185A
2.344A
399.666
90.695%
1471
37.8
39.17°C
0.99
11.898V
5.085V
3.225V
4.908V
440.669
44.82°C
230.35V
90%
30.990A
8.355A
8.703A
2.451A
449.915
90.214%
1470
37.8
39.75°C
0.991
11.855V
5.088V
3.217V
4.896V
498.719
46.12°C
230.35V
100%
34.674A
8.844A
9.251A
3.076A
499.446
89.679%
1474
37.9
40.14°C
0.992
11.817V
5.089V
3.21V
4.877V
556.926
47.29°C
230.36V
110%
38.313A
9.842A
10.416A
3.085A
549.709
88.926%
1474
37.9
40.21°C
0.993
11.782V
5.081V
3.197V
4.864V
618.163
48.12°C
230.36V
CL1
1.916A
14.841A
14.712A
0.504A
146.4
86.479%
1123
30.3
37.51°C
0.961
12.533V
4.865V
3.242V
4.96V
169.289
41.68°C
230.36V
CL2
1.912A
19.791A
1.011A
0.502A
126.509
87.01%
1209
32.4
38.55°C
0.954
12.559V
4.886V
3.263V
4.979V
145.395
43.72°C
230.36V
CL3
1.954A
1.005A
22.934A
0.505A
105.707
82.297%
1232
32.8
39.88°C
0.946
12.283V
4.98V
3.235V
4.957V
128.446
46.29°C
230.36V
CL4
42.657A
0.953A
1.021A
0.506A
499.736
89.292%
1440
37.3
40.87°C
0.992
11.462V
5.247V
3.232V
4.939V
559.663
48.92°C
230.37V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.222A
0.488A
0.499A
0.199A
20.002
76.013%
933
25.0
32.27°C
0.901
12.150V
5.119V
3.305V
5.022V
26.314
33.4°C
115.16V
40W
2.704A
0.682A
0.7A
0.299A
40.001
84.315%
954
25.6
33.19°C
0.941
12.090V
5.134V
3.301V
5.017V
47.442
34.98°C
115.15V
60W
4.187A
0.876A
0.9A
0.399A
60
87.415%
948
25.4
33.3°C
0.958
12.068V
5.138V
3.299V
5.013V
68.638
35.43°C
115.15V
80W
5.671A
1.071A
1.101A
0.499A
79.959
88.853%
975
26.4
34.41°C
0.97
12.049V
5.136V
3.296V
5.008V
89.99
36.87°C
115.15V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.489A
0.5A
0.199A
19.998
73.466%
968
26.1
33.38°C
0.716
12.092V
5.112V
3.298V
5.023V
27.221
34.56°C
230.3V
40W
2.704A
0.684A
0.701A
0.299A
39.997
83.049%
986
26.8
33.75°C
0.835
12.090V
5.117V
3.295V
5.018V
48.161
35.24°C
230.3V
60W
4.198A
0.878A
0.902A
0.399A
59.997
86.7%
996
27.1
34.59°C
0.887
12.036V
5.127V
3.293V
5.012V
69.2
36.39°C
230.3V
80W
5.680A
1.072A
1.103A
0.499A
79.951
88.837%
1017
27.8
34.88°C
0.916
12.028V
5.13V
3.29V
5.008V
89.997
37.11°C
230.31V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.67mV
19.59mV
10.90mV
15.29mV
Pass
20% Load
26.00mV
18.77mV
17.14mV
15.86mV
Pass
30% Load
35.40mV
27.10mV
21.09mV
10.91mV
Pass
40% Load
33.71mV
27.30mV
17.09mV
10.30mV
Pass
50% Load
34.58mV
28.59mV
18.02mV
10.76mV
Pass
60% Load
38.31mV
32.27mV
18.22mV
13.10mV
Pass
70% Load
42.45mV
33.85mV
17.87mV
14.37mV
Pass
80% Load
48.42mV
44.39mV
21.34mV
16.16mV
Pass
90% Load
54.40mV
45.92mV
20.16mV
17.49mV
Pass
100% Load
68.44mV
58.22mV
36.75mV
20.37mV
Fail
110% Load
95.37mV
73.19mV
38.03mV
22.79mV
Fail
Crossload1
40.07mV
88.07mV
30.86mV
17.06mV
Fail
Crossload2
36.57mV
74.20mV
19.50mV
16.97mV
Fail
Crossload3
32.69mV
62.49mV
22.01mV
14.07mV
Fail
Crossload4
75.26mV
89.01mV
32.12mV
20.17mV
Fail
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
28.35mV
21.12mV
11.62mV
14.89mV
Pass
20% Load
25.90mV
17.95mV
11.21mV
18.40mV
Pass
30% Load
28.76mV
21.33mV
10.95mV
19.98mV
Pass
40% Load
30.34mV
25.82mV
12.44mV
19.83mV
Pass
50% Load
33.97mV
29.00mV
13.20mV
10.71mV
Pass
60% Load
37.18mV
33.59mV
13.82mV
12.09mV
Pass
70% Load
39.02mV
43.31mV
14.90mV
13.97mV
Pass
80% Load
45.36mV
40.19mV
21.34mV
18.00mV
Pass
90% Load
51.28mV
46.07mV
21.09mV
18.81mV
Pass
100% Load
70.00mV
61.90mV
36.41mV
21.26mV
Fail
110% Load
86.71mV
70.80mV
40.68mV
22.12mV
Fail
Crossload1
38.04mV
89.69mV
25.11mV
17.98mV
Fail
Crossload2
35.60mV
71.95mV
14.43mV
16.97mV
Fail
Crossload3
32.28mV
65.86mV
21.70mV
16.67mV
Fail
Crossload4
67.63mV
91.23mV
32.32mV
20.43mV
Fail
The results above are not used in the certification process
SilverStone Strider Essential 500W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted