This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
66.154%
0.036
5.125V
0.325
115.10V
2
0.087A
0.448
73.443%
0.066
5.123V
0.610
115.10V
3
0.542A
2.766
80.430%
0.278
5.100V
3.439
115.09V
4
1.002A
5.089
80.688%
0.372
5.077V
6.307
115.09V
5
1.502A
7.590
80.925%
0.422
5.054V
9.379
115.09V
6
2.502A
12.524
79.715%
0.471
5.006V
15.711
115.09V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.563A
2.005A
1.979A
0.986A
64.809
86.765%
660
23.8
38.05°C
0.956
12.128V
4.991V
3.332V
5.066V
74.695
40.86°C
115.10V
2
8.157A
3.001A
2.968A
1.186A
129.777
90.585%
660
23.8
38.30°C
0.985
12.128V
4.990V
3.331V
5.049V
143.266
41.29°C
115.10V
3
13.096A
3.508A
3.477A
1.390A
194.901
91.733%
660
23.8
38.69°C
0.993
12.128V
4.989V
3.329V
5.033V
212.466
41.86°C
115.10V
4
18.023A
4.009A
3.962A
1.593A
259.756
91.962%
812
26.7
39.17°C
0.996
12.128V
4.988V
3.328V
5.016V
282.461
42.53°C
115.10V
5
22.611A
5.009A
4.958A
1.800A
324.691
91.627%
1172
34.8
39.60°C
0.993
12.128V
4.986V
3.327V
4.997V
354.360
43.29°C
115.09V
6
27.202A
6.016A
5.951A
2.006A
389.673
91.096%
1650
46.1
40.54°C
0.990
12.128V
4.985V
3.325V
4.980V
427.762
44.59°C
115.08V
7
31.790A
7.020A
6.946A
2.215A
454.609
90.434%
1975
48.5
41.37°C
0.991
12.128V
4.983V
3.324V
4.962V
502.695
45.84°C
115.07V
8
36.378A
8.034A
7.939A
2.425A
519.620
89.836%
2123
51.2
42.15°C
0.992
12.129V
4.981V
3.323V
4.945V
578.409
47.38°C
115.07V
9
41.390A
8.532A
8.455A
2.428A
584.635
89.363%
2123
51.2
43.04°C
0.992
12.130V
4.980V
3.323V
4.938V
654.224
48.53°C
115.07V
10
46.352A
9.048A
8.939A
2.534A
649.510
88.763%
2123
51.2
44.14°C
0.993
12.131V
4.978V
3.321V
4.928V
731.732
50.48°C
115.07V
11
51.682A
9.050A
8.942A
2.537A
714.374
87.947%
2123
51.2
46.09°C
0.994
12.135V
4.977V
3.320V
4.921V
812.277
52.73°C
115.07V
CL1
0.101A
12.012A
12.004A
0.005A
101.225
85.043%
2115
50.7
44.19°C
0.976
12.135V
4.990V
3.335V
5.107V
119.028
47.40°C
115.10V
CL2
53.966A
1.003A
1.003A
1.002A
668.239
88.897%
2123
51.2
44.24°C
0.993
12.135V
4.985V
3.322V
5.019V
751.697
50.04°C
115.08V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.206A
0.501A
0.476A
0.196A
19.720
74.373%
0
<6.0
0.810
12.127V
4.999V
3.335V
5.113V
26.515
115.10V
2
2.433A
1.000A
0.989A
0.391A
39.796
83.652%
0
<6.0
0.911
12.129V
4.996V
3.333V
5.099V
47.573
115.10V
3
3.667A
1.497A
1.499A
0.586A
59.926
86.605%
660
23.8
0.951
12.129V
4.991V
3.332V
5.088V
69.195
115.10V
4
4.884A
2.005A
1.978A
0.785A
79.813
88.298%
660
23.8
0.965
12.128V
4.991V
3.331V
5.076V
90.390
115.10V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.0 mV
5.2 mV
5.9 mV
7.0 mV
Pass
20% Load
12.0 mV
5.0 mV
6.3 mV
7.4 mV
Pass
30% Load
14.6 mV
4.7 mV
6.4 mV
8.6 mV
Pass
40% Load
17.7 mV
4.3 mV
5.2 mV
8.8 mV
Pass
50% Load
20.5 mV
4.6 mV
5.3 mV
10.1 mV
Pass
60% Load
20.7 mV
4.9 mV
5.9 mV
12.0 mV
Pass
70% Load
19.7 mV
5.2 mV
6.3 mV
13.9 mV
Pass
80% Load
21.0 mV
5.8 mV
7.7 mV
15.6 mV
Pass
90% Load
24.0 mV
6.6 mV
8.2 mV
16.8 mV
Pass
100% Load
28.3 mV
7.1 mV
9.2 mV
19.4 mV
Pass
110% Load
30.8 mV
7.1 mV
9.7 mV
21.6 mV
Pass
Crossload 1
11.5 mV
7.6 mV
9.5 mV
6.2 mV
Pass
Crossload 2
28.1 mV
5.4 mV
6.6 mV
15.7 mV
Pass
The results above are not used in the certification process
SeaSonic Prime Platinum 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted