This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.209
65.723%
0.035
5.003V
0.318
115.10V
2
0.087A
0.437
73.077%
0.065
5.001V
0.598
115.11V
3
0.542A
2.701
80.172%
0.274
4.982V
3.369
115.10V
4
1.002A
4.971
79.984%
0.368
4.961V
6.215
115.10V
5
1.502A
7.419
80.249%
0.418
4.940V
9.245
115.10V
6
3.001A
14.643
78.972%
0.484
4.879V
18.542
115.10V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.377A
1.986A
1.983A
0.996A
99.827
90.279%
685
25.4
38.13°C
0.980
12.274V
5.026V
3.323V
5.004V
110.576
43.76°C
115.08V
2
13.758A
2.980A
2.979A
1.200A
199.715
92.514%
685
25.4
38.39°C
0.986
12.273V
5.024V
3.321V
4.999V
215.876
44.25°C
115.07V
3
21.496A
3.487A
3.490A
1.401A
299.893
93.017%
685
25.4
38.67°C
0.987
12.272V
5.023V
3.319V
4.993V
322.407
44.89°C
115.06V
4
29.219A
3.985A
3.976A
1.601A
399.735
92.954%
726
26.0
38.88°C
0.991
12.271V
5.021V
3.318V
4.989V
430.036
45.72°C
115.06V
5
36.609A
4.978A
4.974A
1.806A
499.670
92.420%
1057
32.2
39.47°C
0.994
12.270V
5.019V
3.316V
4.983V
540.650
46.50°C
115.06V
6
44.002A
5.979A
5.973A
2.006A
599.636
91.504%
1650
46.1
40.67°C
0.996
12.269V
5.017V
3.314V
4.977V
655.308
47.91°C
115.07V
7
51.390A
6.981A
6.971A
2.211A
699.596
90.653%
2043
48.8
41.42°C
0.997
12.269V
5.015V
3.312V
4.972V
771.727
49.20°C
115.07V
8
58.771A
7.978A
7.971A
2.415A
799.511
90.004%
2132
51.7
42.70°C
0.997
12.270V
5.014V
3.311V
4.968V
888.306
50.96°C
115.08V
9
66.566A
8.480A
8.487A
2.415A
899.481
89.397%
2132
51.7
43.81°C
0.998
12.272V
5.012V
3.309V
4.968V
1006.166
52.51°C
115.08V
10
74.112A
8.987A
8.976A
3.028A
999.295
88.601%
2132
51.7
45.15°C
0.998
12.273V
5.011V
3.308V
4.951V
1127.855
54.27°C
115.09V
11
82.232A
8.988A
8.979A
3.029A
1099.197
87.708%
2140
52.5
46.59°C
0.998
12.276V
5.010V
3.307V
4.950V
1253.253
56.44°C
115.07V
CL1
0.100A
15.018A
15.004A
0.005A
126.413
84.919%
2123
51.2
43.62°C
0.988
12.292V
5.020V
3.317V
5.044V
148.863
49.62°C
115.09V
CL2
82.940A
1.002A
1.004A
1.002A
1030.862
88.641%
2132
51.7
44.53°C
0.998
12.268V
5.016V
3.312V
4.993V
1162.961
52.05°C
115.10V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.191A
0.489A
0.480A
0.196A
19.655
74.215%
0
<6.0
0.819
12.270V
5.031V
3.327V
5.027V
26.484
115.08V
2
2.409A
0.989A
0.991A
0.396A
39.818
83.875%
0
<6.0
0.917
12.273V
5.027V
3.323V
5.018V
47.473
115.08V
3
3.620A
1.486A
1.502A
0.596A
59.889
87.872%
0
<6.0
0.953
12.276V
5.028V
3.323V
5.013V
68.155
115.08V
4
4.827A
1.985A
1.985A
0.796A
79.808
88.937%
685
25.4
0.970
12.274V
5.027V
3.323V
5.009V
89.735
115.08V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.0 mV
3.3 mV
4.2 mV
5.5 mV
Pass
20% Load
9.0 mV
4.2 mV
4.9 mV
6.8 mV
Pass
30% Load
11.3 mV
4.5 mV
5.8 mV
7.5 mV
Pass
40% Load
12.0 mV
5.1 mV
6.5 mV
8.0 mV
Pass
50% Load
13.4 mV
5.6 mV
6.8 mV
9.5 mV
Pass
60% Load
13.8 mV
6.2 mV
7.6 mV
10.7 mV
Pass
70% Load
14.1 mV
6.7 mV
7.8 mV
11.4 mV
Pass
80% Load
15.7 mV
6.9 mV
8.2 mV
13.4 mV
Pass
90% Load
18.2 mV
7.2 mV
8.7 mV
14.6 mV
Pass
100% Load
19.5 mV
7.9 mV
9.8 mV
16.2 mV
Pass
110% Load
20.1 mV
8.3 mV
10.5 mV
18.0 mV
Pass
Crossload 1
12.4 mV
4.7 mV
8.3 mV
6.5 mV
Pass
Crossload 2
21.2 mV
5.9 mV
10.2 mV
14.2 mV
Pass
The results above are not used in the certification process
SeaSonic Prime Platinum 1000W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted