This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
67.286%
0.033
5.103V
0.342W
115.17V
2
0.09A
0.459W
74.048%
0.059
5.101V
0.62W
115.17V
3
0.55A
2.8W
81.46%
0.257
5.09V
3.437W
115.17V
4
1A
5.079W
81.66%
0.355
5.078V
6.22W
115.17V
5
1.5A
7.599W
81.566%
0.412
5.065V
9.316W
115.17V
6
2.501A
12.602W
81.118%
0.468
5.04V
15.535W
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.23W
59.144%
0.011
5.103V
0.389W
230.36V
2
0.09A
0.459W
68.369%
0.02
5.101V
0.671W
230.36V
3
0.55A
2.8W
79.758%
0.098
5.089V
3.511W
230.36V
4
1A
5.079W
81.087%
0.163
5.078V
6.264W
230.36V
5
1.5A
7.599W
81.457%
0.221
5.065V
9.329W
230.36V
6
2.501A
12.6W
82.035%
0.299
5.039V
15.359W
230.36V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
3.976A
1.968A
1.966A
1.005A
69.999
89.1%
46.22°C
0.955
12.174V
5.083V
3.357V
4.977V
78.562
40.84°C
115.15V
20%
8.951A
2.956A
2.955A
1.21A
139.946
92.382%
46.84°C
0.982
12.183V
5.075V
3.35V
4.962V
151.486
41.16°C
115.16V
30%
14.279A
3.454A
3.455A
1.415A
209.987
92.996%
47.64°C
0.989
12.181V
5.068V
3.343V
4.947V
225.803
41.32°C
115.16V
40%
19.610A
3.952A
3.956A
1.622A
280.04
93.171%
49.14°C
0.993
12.179V
5.061V
3.336V
4.932V
300.567
42.26°C
115.16V
50%
24.595A
4.948A
4.957A
1.831A
349.999
93.211%
49.58°C
0.997
12.177V
5.054V
3.329V
4.916V
375.492
42.3°C
115.16V
60%
29.589A
5.947A
5.966A
2.001A
419.805
92.898%
50.52°C
0.995
12.173V
5.046V
3.319V
4.9V
451.897
42.74°C
115.16V
70%
34.593A
6.951A
6.978A
2.254A
490.129
92.505%
51.72°C
0.996
12.170V
5.037V
3.311V
4.881V
529.841
43.18°C
115.17V
80%
39.595A
7.958A
7.995A
2.363A
559.74
92.124%
52.82°C
0.996
12.169V
5.028V
3.302V
4.867V
607.591
43.78°C
115.17V
90%
45.000A
8.47A
8.501A
2.473A
629.976
91.711%
54.61°C
0.997
12.166V
5.019V
3.293V
4.853V
686.914
44.75°C
115.18V
100%
50.405A
8.985A
9.041A
2.584A
700.314
91.244%
56.31°C
0.997
12.163V
5.009V
3.285V
4.838V
767.516
45.72°C
115.18V
110%
55.420A
10.005A
10.173A
2.592A
769.721
90.683%
58.46°C
0.998
12.160V
4.998V
3.273V
4.824V
848.805
46.72°C
115.19V
CL1
0.115A
11.882A
11.917A
0A
101.309
88.219%
49.38°C
0.974
12.174V
5.067V
3.331V
4.987V
114.838
42.77°C
115.19V
CL2
0.115A
19.688A
0A
0A
101.399
87.244%
50.98°C
0.974
12.176V
5.079V
3.339V
5.019V
116.225
43.77°C
115.19V
CL3
0.115A
0A
19.768A
0A
67.392
82.31%
52.8°C
0.958
12.165V
5.057V
3.339V
4.977V
81.876
44.72°C
115.19V
CL4
57.565A
0A
0A
0A
700.165
92.061%
55.39°C
0.997
12.163V
5.02V
3.306V
4.929V
760.546
45.64°C
115.18V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
3.976A
1.968A
1.966A
1.005A
70.002
89.725%
45.62°C
0.748
12.171V
5.082V
3.357V
4.975V
78.018
40.74°C
230.4V
20%
8.954A
2.957A
2.957A
1.21A
139.952
93.323%
46.28°C
0.887
12.179V
5.073V
3.348V
4.96V
149.965
40.93°C
230.39V
30%
14.283A
3.455A
3.458A
1.416A
209.989
94.234%
47.43°C
0.936
12.177V
5.066V
3.34V
4.945V
222.839
41.38°C
230.4V
40%
19.615A
3.955A
3.96A
1.623A
280.033
94.531%
48.34°C
0.958
12.176V
5.058V
3.333V
4.929V
296.234
41.83°C
230.4V
50%
24.600A
4.952A
4.963A
1.832A
349.986
94.58%
49.75°C
0.97
12.174V
5.05V
3.325V
4.913V
370.041
42.56°C
230.41V
60%
29.585A
5.952A
5.971A
2A
419.705
94.459%
50.86°C
0.976
12.171V
5.041V
3.316V
4.897V
444.323
43.14°C
230.41V
70%
34.588A
6.956A
6.985A
2.255A
490.031
94.235%
52.23°C
0.981
12.170V
5.033V
3.307V
4.879V
520.01
43.83°C
230.42V
80%
39.594A
7.964A
8.003A
2.364A
559.656
94.011%
52.93°C
0.984
12.167V
5.024V
3.298V
4.864V
595.308
44.21°C
230.42V
90%
44.996A
8.474A
8.509A
2.474A
629.875
93.789%
54.2°C
0.987
12.165V
5.016V
3.29V
4.851V
671.59
44.6°C
230.42V
100%
50.408A
8.989A
9.05A
2.585A
700.244
93.486%
56.41°C
0.988
12.162V
5.006V
3.281V
4.835V
749.036
45.71°C
230.43V
110%
55.421A
10.01A
10.18A
2.592A
769.653
93.129%
58.31°C
0.99
12.158V
4.995V
3.271V
4.823V
826.435
46.56°C
230.43V
CL1
0.115A
11.883A
11.917A
0A
101.3
89.044%
49.54°C
0.84
12.173V
5.066V
3.331V
4.986V
113.765
42.9°C
230.41V
CL2
0.115A
19.689A
0A
0A
101.395
88.079%
50.34°C
0.842
12.175V
5.079V
3.338V
5.017V
115.119
43.09°C
230.4V
CL3
0.115A
0A
19.767A
0A
67.387
83.023%
52.45°C
0.758
12.164V
5.057V
3.339V
4.977V
81.167
44.22°C
230.4V
CL4
57.561A
0A
0A
0A
700.084
94.36%
55.33°C
0.988
12.163V
5.019V
3.305V
4.928V
741.93
45.91°C
230.42V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.220A
0.491A
0.49A
0.2A
19.997
76.602%
39.62°C
0.794
12.177V
5.088V
3.366V
5.007V
26.105
36.5°C
115.14V
40W
2.684A
0.688A
0.687A
0.3A
39.996
85.771%
41.31°C
0.908
12.176V
5.086V
3.364V
5.002V
46.631
37.52°C
115.14V
60W
4.150A
0.885A
0.883A
0.4A
59.995
89.013%
43.26°C
0.946
12.174V
5.085V
3.362V
4.997V
67.401
38.95°C
115.15V
80W
5.608A
1.082A
1.08A
0.501A
79.947
90.515%
45.13°C
0.963
12.180V
5.084V
3.359V
4.991V
88.325
40.1°C
115.15V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.220A
0.491A
0.49A
0.2A
20.003
77.731%
40.14°C
0.447
12.171V
5.087V
3.365V
5.006V
25.734
36.86°C
230.4V
40W
2.686A
0.688A
0.687A
0.3A
40.002
86.196%
40.1°C
0.612
12.171V
5.085V
3.363V
5.001V
46.408
37.34°C
230.4V
60W
4.152A
0.885A
0.884A
0.401A
60.001
89.59%
41.19°C
0.71
12.170V
5.084V
3.361V
4.995V
66.973
37.89°C
230.4V
80W
5.612A
1.082A
1.081A
0.501A
79.966
91.416%
43.07°C
0.776
12.177V
5.083V
3.358V
4.99V
87.475
39.33°C
230.41V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.00mV
8.13mV
5.99mV
7.14mV
Pass
20% Load
19.04mV
8.49mV
5.48mV
6.63mV
Pass
30% Load
20.62mV
9.87mV
5.84mV
7.44mV
Pass
40% Load
18.22mV
9.77mV
5.73mV
7.39mV
Pass
50% Load
12.19mV
10.38mV
6.09mV
8.36mV
Pass
60% Load
10.50mV
11.55mV
6.40mV
8.87mV
Pass
70% Load
10.98mV
12.12mV
6.40mV
8.26mV
Pass
80% Load
12.72mV
12.58mV
11.21mV
9.94mV
Pass
90% Load
13.74mV
13.25mV
11.15mV
9.28mV
Pass
100% Load
23.90mV
15.10mV
12.43mV
12.25mV
Pass
110% Load
25.55mV
16.38mV
13.08mV
13.60mV
Pass
Crossload1
21.21mV
10.58mV
12.88mV
7.20mV
Pass
Crossload2
18.48mV
10.79mV
6.60mV
6.83mV
Pass
Crossload3
17.06mV
12.58mV
20.93mV
10.45mV
Pass
Crossload4
23.60mV
14.50mV
7.18mV
13.70mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
19.94mV
7.88mV
5.84mV
7.24mV
Pass
20% Load
20.67mV
8.49mV
5.84mV
6.83mV
Pass
30% Load
21.28mV
9.26mV
5.89mV
6.88mV
Pass
40% Load
17.86mV
9.87mV
6.20mV
7.09mV
Pass
50% Load
11.84mV
10.53mV
6.45mV
8.01mV
Pass
60% Load
9.89mV
11.71mV
7.06mV
7.85mV
Pass
70% Load
11.39mV
12.17mV
7.21mV
8.87mV
Pass
80% Load
12.21mV
12.68mV
11.36mV
9.07mV
Pass
90% Load
14.29mV
13.65mV
11.57mV
9.53mV
Pass
100% Load
24.39mV
15.48mV
12.66mV
11.89mV
Pass
110% Load
26.03mV
16.03mV
13.21mV
12.75mV
Pass
Crossload1
23.07mV
10.93mV
12.76mV
7.23mV
Pass
Crossload2
20.26mV
11.04mV
6.65mV
7.19mV
Pass
Crossload3
21.08mV
12.63mV
21.80mV
10.15mV
Pass
Crossload4
24.69mV
13.89mV
7.21mV
13.00mV
Pass
The results above are not used in the certification process
Seasonic Prime Fanless TX-700 (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted